More checks neededGE
Sleeve: GE RAB26A, GE RAB46B documented
Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Nominal supply
- 115 V
- Nominal cooling rating
- 7,800 BTU/h
- Heating
- Cooling only
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 10.6
Inverter documentedWi-Fi documented
Installation: GE RAB26A · required kit included; GE RAB46B · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: GE RAB26A, GE RAB46B. Installation conditions apply.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (6)
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
GE RAB26A
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB26A with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
GE RAB46B
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB46B with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
Evidence for this model and installation
- GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
- GE AJCQ08AXXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AJCQ08AXXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- GE projected Quick Specs — AJCQ08AXXWA, AJCQ12AXXWA ↗Single-page exact-model sheet: drawing, CEER and plug/circuit rows; explicitly marked Projected specifications — subject to change. Not final electrical evidence. · Checked 2026-10-12
2025/2026 inverter generation; exact full SKU covered by 49-5001195
Manufacturer specifications ↗More checks neededGE
Sleeve: GE RAB26A, GE RAB46B documented
Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Nominal supply
- 115 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 10.5
Inverter documentedWi-Fi documented
Installation: GE RAB26A · required kit included; GE RAB46B · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: GE RAB26A, GE RAB46B. Installation conditions apply.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (6)
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
GE RAB26A
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB26A with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
GE RAB46B
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB46B with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
Evidence for this model and installation
- GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
- GE AJCQ12AXXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AJCQ12AXXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- GE projected Quick Specs — AJCQ08AXXWA, AJCQ12AXXWA ↗Single-page exact-model sheet: drawing, CEER and plug/circuit rows; explicitly marked Projected specifications — subject to change. Not final electrical evidence. · Checked 2026-10-12
- GE AJCQ12AXXWA — conflicting FEATURES EER ↗Specs & Details > FEATURES > EER: 10.6. CAPACITY > Cooling EER in the same page reports 10.5. These are two section citations, not independent documents. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001195
Manufacturer specifications ↗More checks neededGE
Sleeve: GE RAB26A, GE RAB46B documented
Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 10.5
Inverter documentedWi-Fi documented
Installation: GE RAB26A · required kit included; GE RAB46B · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: GE RAB26A, GE RAB46B. Installation conditions apply.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (6)
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
GE RAB26A
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB26A with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
GE RAB46B
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB46B with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
Evidence for this model and installation
- GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
- GE AJCQ12DXXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AJCQ12DXXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- GE projected Quick Specs — AJCQ12DXXWA ↗Single-page exact-model sheet: drawing, CEER and plug/circuit rows; explicitly marked Projected specifications — subject to change. Not final electrical evidence. · Checked 2026-10-12
2025/2026 inverter generation; exact full SKU covered by 49-5001195
Manufacturer specifications ↗More checks neededGE
Sleeve: GE RAB26A, GE RAB46B documented
Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Electric heat
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.5
Inverter documentedWi-Fi documented
Installation: GE RAB26A · required kit included; GE RAB46B · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: GE RAB26A, GE RAB46B. Installation conditions apply.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (6)
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
GE RAB26A
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB26A with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
- For heat-capable models, apply all page-16 combustible-material clearances: sides 1 in, front and exterior rear 20 in, above 39-3/8 in, below as the manual’s 4-7/8–6-3/8 in range. Resolve the applicable bottom clearance for the actual installation; do not select an endpoint as a general rule.
GE RAB46B
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB46B with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
- For heat-capable models, apply all page-16 combustible-material clearances: sides 1 in, front and exterior rear 20 in, above 39-3/8 in, below as the manual’s 4-7/8–6-3/8 in range. Resolve the applicable bottom clearance for the actual installation; do not select an endpoint as a general rule.
Evidence for this model and installation
- GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
- GE AJEQ12DCXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AJEQ12DCXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- GE projected Quick Specs — AJEQ12DCXWA ↗Single-page exact-model sheet: drawing, CEER and plug/circuit rows; explicitly marked Projected specifications — subject to change. Not final electrical evidence. · Checked 2026-10-12
2025/2026 inverter generation; exact full SKU covered by 49-5001195
Manufacturer specifications ↗More checks neededGE
Sleeve: GE RAB26A, GE RAB46B documented
Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Nominal supply
- 115 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Heat pump with electric backup
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.6
Inverter documentedWi-Fi documented
Installation: GE RAB26A · required kit included; GE RAB46B · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: GE RAB26A, GE RAB46B. Installation conditions apply.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (6)
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
GE RAB26A
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB26A with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
- For heat-capable models, apply all page-16 combustible-material clearances: sides 1 in, front and exterior rear 20 in, above 39-3/8 in, below as the manual’s 4-7/8–6-3/8 in range. Resolve the applicable bottom clearance for the actual installation; do not select an endpoint as a general rule.
GE RAB46B
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB46B with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
- For heat-capable models, apply all page-16 combustible-material clearances: sides 1 in, front and exterior rear 20 in, above 39-3/8 in, below as the manual’s 4-7/8–6-3/8 in range. Resolve the applicable bottom clearance for the actual installation; do not select an endpoint as a general rule.
Evidence for this model and installation
- GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
- GE AJVQ12ACXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AJVQ12ACXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001195
Manufacturer specifications ↗More checks neededGE
Sleeve: GE RAB26A, GE RAB46B documented
Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Heat pump with electric backup
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.5
Inverter documentedWi-Fi documented
Installation: GE RAB26A · required kit included; GE RAB46B · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: GE RAB26A, GE RAB46B. Installation conditions apply.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (6)
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
GE RAB26A
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB26A with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
- For heat-capable models, apply all page-16 combustible-material clearances: sides 1 in, front and exterior rear 20 in, above 39-3/8 in, below as the manual’s 4-7/8–6-3/8 in range. Resolve the applicable bottom clearance for the actual installation; do not select an endpoint as a general rule.
GE RAB46B
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB46B with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
- For heat-capable models, apply all page-16 combustible-material clearances: sides 1 in, front and exterior rear 20 in, above 39-3/8 in, below as the manual’s 4-7/8–6-3/8 in range. Resolve the applicable bottom clearance for the actual installation; do not select an endpoint as a general rule.
Evidence for this model and installation
- GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
- GE AJVQ12DCXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AJVQ12DCXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001195
Manufacturer specifications ↗More checks neededGE
Sleeve: GE RAB24 documented
Next check: GE lists 15 A in preliminary specifications. Confirm the circuit rating for the exact production unit before purchase.
- Nominal supply
- 115 V
- Nominal cooling rating
- 7,800 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.6
Inverter documented
Installation: GE RAB24 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: GE RAB24. Installation conditions apply.
Verify circuit ratingWhy these facts need checking
- GE lists 15 A in preliminary specifications. Confirm the circuit rating for the exact production unit before purchase.
Checks before purchase (6)
- Confirm the actual supply voltage.
- GE lists 15 A in preliminary specifications. Confirm the circuit rating for the exact production unit before purchase.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
GE RAB24
Manufacturer sleeve association; listed conditions apply.
Supplied grille, seals, trim, grounding wire and 24-inch security brackets; use applicable parts · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB24 with the supplied stamped aluminum outdoor grille.
- Use the 24-inch sleeve brackets and the applicable sealing, grounding, grille and trim procedures on printed pages 15–24.
- Confirm exact nameplate, grounded outlet and circuit; the sleeve association does not prove electrical suitability.
- RAB24 sleeve is purchased separately; supplied trim/installation hardware is not a wall sleeve.
- Use the applicable sleeve procedure: secure sound housing, required rearward slope, supplied grounding wire with toothed washers, seals and trim; do not leave required hardware unused.
- Use the supplied 24-inch brackets for RAB24 or 26-inch brackets for RAB26A, with flanges behind the sleeve edge; attach both sides as specified on page 24.
Evidence for this model and installation
- GE 24-inch inverter owner and installation manual ↗Cover lists all four exact AK models and INVERTER. Printed/PDF pages 15–19 and 23–24: bare chassis, RAB24/RAB26A, supplied hardware, rearward slope, grounding, GE rear grille, trim and correct 24/26-inch security brackets. RAB26A recommendation spells RAG13 (not RAG13A). No numeric branch-circuit requirement. Printed pages 16 and 18 list the 27 × 16-3/4 × 16-3/4 in Friedrich housing and its existing-sleeve adaptation with the supplied rear louver, blocks, seals and grounding. · Checked 2026-11-22
- GE AKCQ08AXXXA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AKCQ08AXXXA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
- GE AKCQ08AXXXA — conflicting FEATURES EER ↗Specs & Details > FEATURES > EER: 9.6. CAPACITY > Cooling EER in the same page reports 10.6. These are two section citations, not independent documents. · Checked 2026-10-13
- GE 2026 Universal Fit 24-inch AC brochure, preliminary circuit size ↗PDF page 8, printed spread pages 14–15, right-hand Cool-Only table. The AKCQ08AXXXA and AKCQ12AXXXA columns show 15 A in Circuit Size Amps. Both pages mark the values projected and subject to change. · Checked 2026-11-22
2025/2026 inverter generation; exact full SKU covered by 49-5001293
Manufacturer specifications ↗More checks neededGE
Sleeve: GE RAB24 documented
Next check: GE lists 15 A in preliminary specifications. Confirm the circuit rating for the exact production unit before purchase.
- Nominal supply
- 115 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.5
Inverter documented
Installation: GE RAB24 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: GE RAB24. Installation conditions apply.
Verify circuit ratingWhy these facts need checking
- GE lists 15 A in preliminary specifications. Confirm the circuit rating for the exact production unit before purchase.
Checks before purchase (6)
- Confirm the actual supply voltage.
- GE lists 15 A in preliminary specifications. Confirm the circuit rating for the exact production unit before purchase.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
GE RAB24
Manufacturer sleeve association; listed conditions apply.
Supplied grille, seals, trim, grounding wire and 24-inch security brackets; use applicable parts · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB24 with the supplied stamped aluminum outdoor grille.
- Use the 24-inch sleeve brackets and the applicable sealing, grounding, grille and trim procedures on printed pages 15–24.
- Confirm exact nameplate, grounded outlet and circuit; the sleeve association does not prove electrical suitability.
- RAB24 sleeve is purchased separately; supplied trim/installation hardware is not a wall sleeve.
- Use the applicable sleeve procedure: secure sound housing, required rearward slope, supplied grounding wire with toothed washers, seals and trim; do not leave required hardware unused.
- Use the supplied 24-inch brackets for RAB24 or 26-inch brackets for RAB26A, with flanges behind the sleeve edge; attach both sides as specified on page 24.
Evidence for this model and installation
- GE 24-inch inverter owner and installation manual ↗Cover lists all four exact AK models and INVERTER. Printed/PDF pages 15–19 and 23–24: bare chassis, RAB24/RAB26A, supplied hardware, rearward slope, grounding, GE rear grille, trim and correct 24/26-inch security brackets. RAB26A recommendation spells RAG13 (not RAG13A). No numeric branch-circuit requirement. Printed pages 16 and 18 list the 27 × 16-3/4 × 16-3/4 in Friedrich housing and its existing-sleeve adaptation with the supplied rear louver, blocks, seals and grounding. · Checked 2026-11-22
- GE AKCQ12AXXXA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AKCQ12AXXXA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
- GE AKCQ12AXXXA — conflicting FEATURES EER ↗Specs & Details > FEATURES > EER: 9.5. CAPACITY > Cooling EER in the same page reports 10.5. These are two section citations, not independent documents. · Checked 2026-10-13
- GE 2026 Universal Fit 24-inch AC brochure, preliminary circuit size ↗PDF page 8, printed spread pages 14–15, right-hand Cool-Only table. The AKCQ08AXXXA and AKCQ12AXXXA columns show 15 A in Circuit Size Amps. Both pages mark the values projected and subject to change. · Checked 2026-11-22
2025/2026 inverter generation; exact full SKU covered by 49-5001293
Manufacturer specifications ↗More checks neededGE
Sleeve: GE RAB24 documented
Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 6-15P
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.5
Inverter documented
Installation: GE RAB24 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: GE RAB24. Installation conditions apply.
Verify circuit ratingWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (6)
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
GE RAB24
Manufacturer sleeve association; listed conditions apply.
Supplied grille, seals, trim, grounding wire and 24-inch security brackets; use applicable parts · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB24 with the supplied stamped aluminum outdoor grille.
- Use the 24-inch sleeve brackets and the applicable sealing, grounding, grille and trim procedures on printed pages 15–24.
- Confirm exact nameplate, grounded outlet and circuit; the sleeve association does not prove electrical suitability.
- RAB24 sleeve is purchased separately; supplied trim/installation hardware is not a wall sleeve.
- Use the applicable sleeve procedure: secure sound housing, required rearward slope, supplied grounding wire with toothed washers, seals and trim; do not leave required hardware unused.
- Use the supplied 24-inch brackets for RAB24 or 26-inch brackets for RAB26A, with flanges behind the sleeve edge; attach both sides as specified on page 24.
Evidence for this model and installation
- GE 24-inch inverter owner and installation manual ↗Cover lists all four exact AK models and INVERTER. Printed/PDF pages 15–19 and 23–24: bare chassis, RAB24/RAB26A, supplied hardware, rearward slope, grounding, GE rear grille, trim and correct 24/26-inch security brackets. RAB26A recommendation spells RAG13 (not RAG13A). No numeric branch-circuit requirement. Printed pages 16 and 18 list the 27 × 16-3/4 × 16-3/4 in Friedrich housing and its existing-sleeve adaptation with the supplied rear louver, blocks, seals and grounding. · Checked 2026-11-22
- GE AKCQ12DXXXA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AKCQ12DXXXA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
- GE AKCQ12DXXXA — conflicting FEATURES EER ↗Specs & Details > FEATURES > EER: 9.5. CAPACITY > Cooling EER in the same page reports 10.5. These are two section citations, not independent documents. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001293
Manufacturer specifications ↗More checks neededGE
Sleeve: GE RAB24 documented
Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Heat pump with electric backup
- Plug
- NEMA 6-20P
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.5
Inverter documentedWi-Fi documented
Installation: GE RAB24 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: GE RAB24. Installation conditions apply.
Verify circuit ratingWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (6)
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
GE RAB24
Manufacturer sleeve association; listed conditions apply.
Supplied grille, seals, trim, grounding wire and 24-inch security brackets; use applicable parts · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB24 with the supplied stamped aluminum outdoor grille.
- Use the 24-inch sleeve brackets and the applicable sealing, grounding, grille and trim procedures on printed pages 15–24.
- Confirm exact nameplate, grounded outlet and circuit; the sleeve association does not prove electrical suitability.
- RAB24 sleeve is purchased separately; supplied trim/installation hardware is not a wall sleeve.
- Use the applicable sleeve procedure: secure sound housing, required rearward slope, supplied grounding wire with toothed washers, seals and trim; do not leave required hardware unused.
- Use the supplied 24-inch brackets for RAB24 or 26-inch brackets for RAB26A, with flanges behind the sleeve edge; attach both sides as specified on page 24.
Evidence for this model and installation
- GE 24-inch inverter owner and installation manual ↗Cover lists all four exact AK models and INVERTER. Printed/PDF pages 15–19 and 23–24: bare chassis, RAB24/RAB26A, supplied hardware, rearward slope, grounding, GE rear grille, trim and correct 24/26-inch security brackets. RAB26A recommendation spells RAG13 (not RAG13A). No numeric branch-circuit requirement. Printed pages 16 and 18 list the 27 × 16-3/4 × 16-3/4 in Friedrich housing and its existing-sleeve adaptation with the supplied rear louver, blocks, seals and grounding. · Checked 2026-11-22
- GE AKVQ12DXXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AKVQ12DXXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001293
Manufacturer specifications ↗More checks neededFrigidaire
Sleeve: Frigidaire 912001373 documented
Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.
- Nominal supply
- 115 V
- Nominal cooling rating
- 10,000 BTU/h
- Heating
- Cooling only
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.6
Installation: Frigidaire 912001373 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Frigidaire 912001373. Installation conditions apply.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
Checks before purchase (7)
- Current production status needs confirmation.
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
Frigidaire 912001373
Manufacturer sleeve association; listed conditions apply.
Supplied rear grille and trim · Required for the listed procedure · Included as reported in source
Wall sleeve for a new installation (912001373) · Optional or conditional · Purchased separately
- The exact Frigidaire product sheet names 912001373 as the separately sold wall sleeve.
- Follow the model installation guide for the supplied rear grille, trim and any required seals or grounding.
- Confirm the rough opening for the actual sleeve at the site before cutting the wall. The AC sheet’s sleeve dimensions do not specify that rough opening.
Evidence for this model and installation
Frigidaire R-32 built-in wall AC / specification edition 02/25
Manufacturer specifications ↗More checks neededFrigidaire
Sleeve: Frigidaire 912001373 documented
Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.
- Nominal supply
- 230 V
- Nominal cooling rating
- 10,000 BTU/h
- Heating
- Cooling only
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.6
Installation: Frigidaire 912001373 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Frigidaire 912001373. Installation conditions apply.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
Checks before purchase (7)
- Current production status needs confirmation.
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
Frigidaire 912001373
Manufacturer sleeve association; listed conditions apply.
Supplied rear grille and trim · Required for the listed procedure · Included as reported in source
Wall sleeve for a new installation (912001373) · Optional or conditional · Purchased separately
- The exact Frigidaire product sheet names 912001373 as the separately sold wall sleeve.
- Follow the model installation guide for the supplied rear grille, trim and any required seals or grounding.
- Confirm the rough opening for the actual sleeve at the site before cutting the wall. The AC sheet’s sleeve dimensions do not specify that rough opening.
Evidence for this model and installation
Frigidaire R-32 built-in wall AC / specification edition 02/25
Manufacturer specifications ↗More checks neededFrigidaire
Sleeve: Frigidaire 912001373 documented
Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.
- Nominal supply
- 115 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.5
Installation: Frigidaire 912001373 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Frigidaire 912001373. Installation conditions apply.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
Checks before purchase (7)
- Current production status needs confirmation.
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
FHTC123WB1 at Abt ↗Store listing checked 2026-11-22 · $819.00 · Listed in stock · ZIP 60601: seller showed delivery · Confirm the sleeve and installation parts separately.
Ordinary store links with no affiliate commission. Check current price, parts and delivery for your ZIP directly with the seller.
Sleeves, required parts and sources
Frigidaire 912001373
Manufacturer sleeve association; listed conditions apply.
Supplied rear grille and trim · Required for the listed procedure · Included as reported in source
Wall sleeve for a new installation (912001373) · Optional or conditional · Purchased separately
- The exact Frigidaire product sheet names 912001373 as the separately sold wall sleeve.
- Follow the model installation guide for the supplied rear grille, trim and any required seals or grounding.
- Confirm the rough opening for the actual sleeve at the site before cutting the wall. The AC sheet’s sleeve dimensions do not specify that rough opening.
Evidence for this model and installation
- Abt listing for exact Frigidaire 912001373 sleeve ↗Model # 912001373; approximate product dimensions, separate from package dimensions. Used for identification only. · Checked 2026-11-22
- Frigidaire FHTC through-the-wall installation guide ↗English page 2: exact WSE row and EA120T trim footnote. Pages 3, 5–9: reuse requirements for old rear grilles and compatible direct mounting/sealing. Page 10: larger front trim accessory and trim installation. Exact FHTC or FHTE product pages link this guide. · Checked 2026-11-22
- Frigidaire FHTC123WB1 exact specifications ↗PDF page 1 lists exact product, performance, voltage, cooling amps/watts and supplied trim. Page 2 lists separately sold sleeve 912001373. · Checked 2026-11-22
- Abt — exact FHTC123WB1 store listing ↗Exact model # FHTC123WB1; price in the product page and InStock on its Product offer. Delivery shown for test ZIP 60601 in the product page shipping control. · Checked 2026-11-22
Frigidaire R-32 built-in wall AC / specification edition 02/25
Manufacturer specifications ↗More checks neededFrigidaire
Sleeve: Frigidaire 912001373 documented
Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.5
Installation: Frigidaire 912001373 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Frigidaire 912001373. Installation conditions apply.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
Checks before purchase (7)
- Current production status needs confirmation.
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
Frigidaire 912001373
Manufacturer sleeve association; listed conditions apply.
Supplied rear grille and trim · Required for the listed procedure · Included as reported in source
Wall sleeve for a new installation (912001373) · Optional or conditional · Purchased separately
- The exact Frigidaire product sheet names 912001373 as the separately sold wall sleeve.
- Follow the model installation guide for the supplied rear grille, trim and any required seals or grounding.
- Confirm the rough opening for the actual sleeve at the site before cutting the wall. The AC sheet’s sleeve dimensions do not specify that rough opening.
Evidence for this model and installation
Frigidaire R-32 built-in wall AC / specification edition 02/25
Manufacturer specifications ↗More checks neededFrigidaire
Sleeve: Frigidaire 912001373 documented
Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.
- Nominal supply
- 230 V
- Nominal cooling rating
- 14,000 BTU/h
- Heating
- Cooling only
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.5
Installation: Frigidaire 912001373 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Frigidaire 912001373. Installation conditions apply.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
Checks before purchase (7)
- Current production status needs confirmation.
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
Frigidaire 912001373
Manufacturer sleeve association; listed conditions apply.
Supplied rear grille and trim · Required for the listed procedure · Included as reported in source
Wall sleeve for a new installation (912001373) · Optional or conditional · Purchased separately
- The exact Frigidaire product sheet names 912001373 as the separately sold wall sleeve.
- Follow the model installation guide for the supplied rear grille, trim and any required seals or grounding.
- Confirm the rough opening for the actual sleeve at the site before cutting the wall. The AC sheet’s sleeve dimensions do not specify that rough opening.
Evidence for this model and installation
Frigidaire R-32 built-in wall AC / specification edition 02/25
Manufacturer specifications ↗More checks neededFrigidaire
Sleeve: Frigidaire 912001373 documented
Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.
- Nominal supply
- 115 V
- Nominal cooling rating
- 8,000 BTU/h
- Heating
- Electric heat
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.6
Installation: Frigidaire 912001373 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Frigidaire 912001373. Installation conditions apply.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
Checks before purchase (7)
- Current production status needs confirmation.
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
Frigidaire 912001373
Manufacturer sleeve association; listed conditions apply.
Supplied rear grille and trim · Required for the listed procedure · Included as reported in source
Wall sleeve for a new installation (912001373) · Optional or conditional · Purchased separately
- The exact Frigidaire product sheet names 912001373 as the separately sold wall sleeve.
- Follow the model installation guide for the supplied rear grille, trim and any required seals or grounding.
- Confirm the rough opening for the actual sleeve at the site before cutting the wall. The AC sheet’s sleeve dimensions do not specify that rough opening.
Evidence for this model and installation
Frigidaire R-32 built-in wall AC / specification edition 11/24
Manufacturer specifications ↗More checks neededFrigidaire
Sleeve: Frigidaire 912001373 documented
Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.
- Nominal supply
- 230 V
- Nominal cooling rating
- 10,000 BTU/h
- Heating
- Electric heat
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.6
Installation: Frigidaire 912001373 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Frigidaire 912001373. Installation conditions apply.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
Checks before purchase (7)
- Current production status needs confirmation.
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
Frigidaire 912001373
Manufacturer sleeve association; listed conditions apply.
Supplied rear grille and trim · Required for the listed procedure · Included as reported in source
Wall sleeve for a new installation (912001373) · Optional or conditional · Purchased separately
- The exact Frigidaire product sheet names 912001373 as the separately sold wall sleeve.
- Follow the model installation guide for the supplied rear grille, trim and any required seals or grounding.
- Confirm the rough opening for the actual sleeve at the site before cutting the wall. The AC sheet’s sleeve dimensions do not specify that rough opening.
Evidence for this model and installation
Frigidaire R-32 built-in wall AC / specification edition 11/24
Manufacturer specifications ↗More checks neededFrigidaire
Sleeve: Frigidaire 912001373 documented
Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Electric heat
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.5
Installation: Frigidaire 912001373 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Frigidaire 912001373. Installation conditions apply.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
Checks before purchase (7)
- Current production status needs confirmation.
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
Frigidaire 912001373
Manufacturer sleeve association; listed conditions apply.
Supplied rear grille and trim · Required for the listed procedure · Included as reported in source
Wall sleeve for a new installation (912001373) · Optional or conditional · Purchased separately
- The exact Frigidaire product sheet names 912001373 as the separately sold wall sleeve.
- Follow the model installation guide for the supplied rear grille, trim and any required seals or grounding.
- Confirm the rough opening for the actual sleeve at the site before cutting the wall. The AC sheet’s sleeve dimensions do not specify that rough opening.
Evidence for this model and installation
Frigidaire R-32 built-in wall AC / specification edition 11/24
Manufacturer specifications ↗More checks neededFrigidaire
Sleeve: Frigidaire 912001373 documented
Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.
- Nominal supply
- 230 V
- Nominal cooling rating
- 14,000 BTU/h
- Heating
- Electric heat
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.5
Installation: Frigidaire 912001373 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Frigidaire 912001373. Installation conditions apply.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
Checks before purchase (7)
- Current production status needs confirmation.
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
Frigidaire 912001373
Manufacturer sleeve association; listed conditions apply.
Supplied rear grille and trim · Required for the listed procedure · Included as reported in source
Wall sleeve for a new installation (912001373) · Optional or conditional · Purchased separately
- The exact Frigidaire product sheet names 912001373 as the separately sold wall sleeve.
- Follow the model installation guide for the supplied rear grille, trim and any required seals or grounding.
- Confirm the rough opening for the actual sleeve at the site before cutting the wall. The AC sheet’s sleeve dimensions do not specify that rough opening.
Evidence for this model and installation
Frigidaire R-32 built-in wall AC / specification edition 11/24
Manufacturer specifications ↗More checks neededKeystone
Sleeve: Keystone KSTSLV1 documented
Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Keystone to confirm it before purchase; your circuit answer cannot fill this gap.
- Nominal supply
- 115 V
- Nominal cooling rating
- 8,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- Not established
Installation: Keystone KSTSLV1 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Keystone KSTSLV1. Installation conditions apply.
Verify circuit ratingWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask Keystone to confirm it before purchase.
Checks before purchase (7)
- Current production status needs confirmation.
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Keystone to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
Keystone KSTSLV1
Manufacturer sleeve association; listed conditions apply.
Supplied rear grille and interior trim · Required for the listed procedure · Included as reported in source
Wall sleeve for a new installation (KSTSLV1) · Optional or conditional · Purchased separately
- The exact AC product page lists KSTSLV1 as the new sleeve, sold separately.
- Use the rear grille supplied with the AC and the applicable trim. Verify the rough opening with the installation instructions before cutting.
- Use the dedicated circuit described in the owner guide and confirm the production-unit circuit rating.
Evidence for this model and installation
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
- Keystone KSTSLV1 sleeve installation instructions ↗PDF page 1, sleeve hardware, rear grille packed with the air conditioner and secure installation. · Checked 2026-11-22
- Keystone D-series through-the-wall specifications ↗PDF page 1, exact KSTSLV1 outside dimension drawing. Page 2, KSTAT08-1D and KSTAT12-1D cooling, electrical and unit dimensions. · Checked 2026-11-22
- Keystone KSTAT08-1D exact product page ↗Exact model number; 115 V, NEMA 5-15P, standard trim, separately sold KSTSLV1 sleeve. · Checked 2026-11-22
- Keystone KSTAT08-1D installation instructions ↗Printed pages 4–5 (PDF pages 1–2): kit contents and existing sleeve chart. Printed page 9 (PDF page 6): 16-3/4 in Friedrich/Fedders #3 procedure with rear grille, seals, supports and grounding. · Checked 2026-11-22
- Keystone KSTAT08-1D owner guide ↗Safety instructions specify a dedicated circuit with a breaker; a numeric circuit rating was not established. · Checked 2026-11-22
Keystone D-series through-the-wall room AC
Manufacturer specifications ↗More checks neededKeystone
Sleeve: Keystone KSTSLV1 documented
Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Keystone to confirm it before purchase; your circuit answer cannot fill this gap.
- Nominal supply
- 115 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- Not established
Installation: Keystone KSTSLV1 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Keystone KSTSLV1. Installation conditions apply.
Verify circuit ratingWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask Keystone to confirm it before purchase.
Checks before purchase (7)
- Current production status needs confirmation.
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Keystone to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
Keystone KSTSLV1
Manufacturer sleeve association; listed conditions apply.
Supplied rear grille and interior trim · Required for the listed procedure · Included as reported in source
Wall sleeve for a new installation (KSTSLV1) · Optional or conditional · Purchased separately
- The exact AC product page lists KSTSLV1 as the new sleeve, sold separately.
- Use the rear grille supplied with the AC and the applicable trim. Verify the rough opening with the installation instructions before cutting.
- Use the dedicated circuit described in the owner guide and confirm the production-unit circuit rating.
Evidence for this model and installation
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
- Keystone KSTSLV1 sleeve installation instructions ↗PDF page 1, sleeve hardware, rear grille packed with the air conditioner and secure installation. · Checked 2026-11-22
- Keystone D-series through-the-wall specifications ↗PDF page 1, exact KSTSLV1 outside dimension drawing. Page 2, KSTAT08-1D and KSTAT12-1D cooling, electrical and unit dimensions. · Checked 2026-11-22
- Keystone KSTAT12-1D exact product page ↗Exact model number; 115 V, NEMA 5-15P, standard trim, separately sold KSTSLV1 sleeve. · Checked 2026-11-22
- Keystone KSTAT12-1D installation instructions ↗Printed pages 4–5 (PDF pages 1–2): kit contents and existing sleeve chart. Printed page 9 (PDF page 6): 16-3/4 in Friedrich/Fedders #3 procedure with rear grille, seals, supports and grounding. · Checked 2026-11-22
- Keystone KSTAT12-1D owner guide ↗Safety instructions specify a dedicated circuit with a breaker; a numeric circuit rating was not established. · Checked 2026-11-22
Keystone D-series through-the-wall room AC
Manufacturer specifications ↗More checks neededLG
Next check: No positive manufacturer sleeve decision is available under these answers.
- Nominal supply
- 230 V
- Nominal cooling rating
- 10,000 BTU/h
- Heating
- Electric heat
- Plug
- NEMA 6-20P
- Specified circuit / fuse
- 20 A
- CEER (nominal rating)
- 10.7
Checks before purchase (7)
- No positive manufacturer sleeve decision is available under these answers.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
LG AXSVA1
Sleeve decision needs review.
Provided installation hardware; apply exact sleeve procedure · Required for the listed procedure · Included as reported in source
- The linked 2013 sheet names this sleeve for an older UPC/generation. The current R32 model has a different UPC and support manual. Do not carry that accessory association into the new generation without an exact manufacturer statement.
- The model-associated manual supplies grille/insulation/shims/trim and describes LGE Procedure A. Follow the exact sleeve procedure and rearward slope; this is not independent evidence identifying this sleeve SKU.
- The R32 heat manual page 11 prohibits installation within 40 in of combustible surfaces. Check all requirements in the exact manual.
LG AXSVA4
Sleeve decision needs review.
Provided installation hardware; apply exact sleeve procedure · Required for the listed procedure · Included as reported in source
- The linked 2013 sheet names this sleeve for an older UPC/generation. The current R32 model has a different UPC and support manual. Do not carry that accessory association into the new generation without an exact manufacturer statement.
- The model-associated manual supplies grille/insulation/shims/trim and describes LGE Procedure A. Follow the exact sleeve procedure and rearward slope; this is not independent evidence identifying this sleeve SKU.
- The R32 heat manual page 11 prohibits installation within 40 in of combustible surfaces. Check all requirements in the exact manual.
Evidence for this model and installation
- LG US wall air conditioner category ↗Eleven LT equipment entries observed in initial category HTML; accessories excluded. Dynamic pagination is not proof of complete coverage. · Checked 2026-10-12
- LG owner manual — heat ↗Selected LT1033HNR.AT3AUSH / LT1233HNR.AT3AUSH support associations; printed/PDF page 9 has consistent perpendicular cord and outlet drawings and a separate explicit 20 A circuit requirement. Pages 11-13: supplied parts, LGE Procedure A and 40 in combustible-surface clearance. The generic LGE sleeve procedure does not establish the exact AXSVA1/AXSVA4 SKU for the current R32 generation. Do not apply to R410A suffixes. · Checked 2026-11-11
- LG LT1033HNR — current product specifications ↗Specifications > Electrical Ratings, Performance, Features and Dimensions/Weight; public page specification data; product modelStatus ACTIVE checked separately from stock. · Checked 2026-10-13
- LG LT1033HNR — exact support/document association ↗Selected support sales suffix and Download Manuals list; suffix is not automatically an alias of another physical generation. · Checked 2026-10-13
- LG LT1033HNR — linked specification sheet ↗Exact SKU specifications, refrigerant and Optional Accessories. Dates differ across PDFs; older electrical/performance tables are not merged into current page values. · Checked 2026-10-12
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
- LG R-32 heat manual — cord drawing ↗Printed/PDF page 9, 230 V power-cord rear view: one horizontal and one vertical blade, matching the 6-20 configuration. Rechecked at enlarged scale 2026-11-11; the earlier two-horizontal-blades transcription was incorrect. PDF SHA-256 f2bc1a0b214bd4419662ead47fc8008e053c83fb8f3dc642496e4def6862ecc4. · Checked 2026-11-11
- LG R-32 heat manual — outlet and circuit table ↗Printed/PDF page 9: perpendicular three-wire grounding receptacle rated 20 A / 250 V and explicit 20 A time-delay fuse/circuit breaker. The cord rear view above has the matching perpendicular blade arrangement, not tandem 15 A blades. · Checked 2026-11-11
Reviewed marketed SKU and UPC 048231606486; selected support LT1033HNR.AT3AUSH. Base model is not an alias of every historical sales suffix.
Manufacturer specifications ↗More checks neededLG
Next check: No positive manufacturer sleeve decision is available under these answers.
- Nominal supply
- 230 V
- Nominal cooling rating
- 11,800 BTU/h
- Heating
- Electric heat
- Plug
- NEMA 6-20P
- Specified circuit / fuse
- 20 A
- CEER (nominal rating)
- 10.2
Checks before purchase (7)
- No positive manufacturer sleeve decision is available under these answers.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
LG AXSVA1
Sleeve decision needs review.
Provided installation hardware; apply exact sleeve procedure · Required for the listed procedure · Included as reported in source
- The linked 2013 sheet names this sleeve for an older UPC/generation. The current R32 model has a different UPC and support manual. Do not carry that accessory association into the new generation without an exact manufacturer statement.
- The model-associated manual supplies grille/insulation/shims/trim and describes LGE Procedure A. Follow the exact sleeve procedure and rearward slope; this is not independent evidence identifying this sleeve SKU.
- The R32 heat manual page 11 prohibits installation within 40 in of combustible surfaces. Check all requirements in the exact manual.
LG AXSVA4
Sleeve decision needs review.
Provided installation hardware; apply exact sleeve procedure · Required for the listed procedure · Included as reported in source
- The linked 2013 sheet names this sleeve for an older UPC/generation. The current R32 model has a different UPC and support manual. Do not carry that accessory association into the new generation without an exact manufacturer statement.
- The model-associated manual supplies grille/insulation/shims/trim and describes LGE Procedure A. Follow the exact sleeve procedure and rearward slope; this is not independent evidence identifying this sleeve SKU.
- The R32 heat manual page 11 prohibits installation within 40 in of combustible surfaces. Check all requirements in the exact manual.
Evidence for this model and installation
- LG US wall air conditioner category ↗Eleven LT equipment entries observed in initial category HTML; accessories excluded. Dynamic pagination is not proof of complete coverage. · Checked 2026-10-12
- LG owner manual — heat ↗Selected LT1033HNR.AT3AUSH / LT1233HNR.AT3AUSH support associations; printed/PDF page 9 has consistent perpendicular cord and outlet drawings and a separate explicit 20 A circuit requirement. Pages 11-13: supplied parts, LGE Procedure A and 40 in combustible-surface clearance. The generic LGE sleeve procedure does not establish the exact AXSVA1/AXSVA4 SKU for the current R32 generation. Do not apply to R410A suffixes. · Checked 2026-11-11
- LG LT1233HNR — current product specifications ↗Specifications > Electrical Ratings, Performance, Features and Dimensions/Weight; public page specification data; product modelStatus ACTIVE checked separately from stock. · Checked 2026-10-13
- LG LT1233HNR — exact support/document association ↗Selected support sales suffix and Download Manuals list; suffix is not automatically an alias of another physical generation. · Checked 2026-10-12
- LG LT1233HNR — linked specification sheet ↗Exact SKU specifications, refrigerant and Optional Accessories. Dates differ across PDFs; older electrical/performance tables are not merged into current page values. · Checked 2026-10-12
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
- LG R-32 heat manual — cord drawing ↗Printed/PDF page 9, 230 V power-cord rear view: one horizontal and one vertical blade, matching the 6-20 configuration. Rechecked at enlarged scale 2026-11-11; the earlier two-horizontal-blades transcription was incorrect. PDF SHA-256 f2bc1a0b214bd4419662ead47fc8008e053c83fb8f3dc642496e4def6862ecc4. · Checked 2026-11-11
- LG R-32 heat manual — outlet and circuit table ↗Printed/PDF page 9: perpendicular three-wire grounding receptacle rated 20 A / 250 V and explicit 20 A time-delay fuse/circuit breaker. The cord rear view above has the matching perpendicular blade arrangement, not tandem 15 A blades. · Checked 2026-11-11
Reviewed marketed SKU and UPC 048231606493; selected support LT1233HNR.AT3AUSH. Base model is not an alias of every historical sales suffix.
Manufacturer specifications ↗More checks neededFriedrich
Sleeve: Friedrich USC, Friedrich USEZ documented
Next check: Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Nominal supply
- 115 V
- Nominal cooling rating
- 8,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.1
Wi-Fi documented
Installation: Friedrich USC · required kit included; Friedrich USEZ · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC, Friedrich USEZ. Installation conditions apply.
Checks before purchase (6)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT08B10A at Abt ↗Store listing checked 2026-11-22 · $799.00 · Listed in stock · ZIP 60601: seller showed delivery · Confirm the sleeve and installation parts separately.
UCT08B10A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links with no affiliate commission. Check current price, parts and delivery for your ZIP directly with the seller.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
- Confirm the USEZ sleeve revision before cutting or reusing an opening. The October 1, 2024 USEZ installation drawing gives a minimum 26-1/4 × 15-3/4 in opening for the sleeve covered by that manual.
- For the USEZ covered by the October 1, 2024 manual, follow page 3 for minimum indoor and outdoor projections, rearward pitch, rear grille and supports.
Evidence for this model and installation
- Uni-Fit 2026 brochure — model specifications ↗Printed page 4 / PDF page 4: all ten UCT/UET B-series, final A-suffix R-32 models · Checked 2026-10-13
- Uni-Fit 2026 brochure — electrical requirements ↗Printed page 5 / PDF page 5: exact model groups, circuit/fuse ratings and NEMA plugs · Checked 2026-10-13
- Uni-Fit 2026 brochure — existing sleeve table ↗Printed page 6 / PDF page 6: explicitly named Friedrich WSE column; chassis dimensions and included decorative trim ring · Checked 2026-10-13
- Uni-Fit 2026 brochure — standard features ↗Printed page 3 / PDF page 3: built-in Wi-Fi and cooling/electric-heat series · Checked 2026-10-13
- Uni-Fit R-32 installation manual — WSE and preparation ↗Cover / PDF page 1 exact models; printed/PDF page 8 packing list; printed/PDF pages 14–16: WSE table, generic sleeve preparation, required rear grille, sealing and grounding · Checked 2026-10-13
- Uni-Fit R-32 installation manual — receptacles ↗Cover / PDF page 1 exact voltage groups; printed page 17 / PDF page 17, Table E.1: receptacle and circuit ratings for corresponding UCT/UET voltage groups · Checked 2026-10-13
- Uni-Fit 2026 — native sleeve and new installation ↗Printed page 6: USC/USEZ required for new installation, sold separately; combined sleeve outside dimensions 25-7/8 W x 15-1/2 H x 16-3/4 D in; finished-opening width 26-1/8 in differs from exact USEZ manual page 3 (26-1/4 in). Included trim ring. The combined table does not resolve the exact USEZ drawing conflict. · Checked 2026-11-11
- USEZ sleeve assembly and installation instructions ↗Printed pages 1, 3 and 5. Page 3 Figures 6–8 specify the assembled USEZ housing, minimum rough opening, projections and pitch for the sleeve covered by this exact manual. Page 5 shows sleeve components and rear grille. · Checked 2026-11-22
- Uni-Fit R-32 manual — supplied installation parts ↗Cover / PDF page 1 exact models; printed/PDF page 8 packing list; pages 14–16 provided dual-intake grille and installation methods · Checked 2026-10-13
- AJ Madison — exact UCT08B10A destination ↗Product heading and model identity only. Retailer specifications are not used as installation evidence; price and stock are not imported. · Checked 2026-10-13
- Abt — exact UCT08B10A store listing ↗Exact model # UCT08B10A; price in the product page and InStock on its Product offer. Delivery shown for test ZIP 60601 in the product page shipping control. · Checked 2026-11-22
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
Sleeve: Friedrich USC, Friedrich USEZ documented
Next check: Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Nominal supply
- 115 V
- Nominal cooling rating
- 10,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.1
Wi-Fi documented
Installation: Friedrich USC · required kit included; Friedrich USEZ · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC, Friedrich USEZ. Installation conditions apply.
Checks before purchase (6)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT10B10A at Abt ↗Store listing checked 2026-11-22 · $849.00 · Listed in stock · ZIP 60601: seller showed delivery · Confirm the sleeve and installation parts separately.
UCT10B10A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links with no affiliate commission. Check current price, parts and delivery for your ZIP directly with the seller.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
- Confirm the USEZ sleeve revision before cutting or reusing an opening. The October 1, 2024 USEZ installation drawing gives a minimum 26-1/4 × 15-3/4 in opening for the sleeve covered by that manual.
- For the USEZ covered by the October 1, 2024 manual, follow page 3 for minimum indoor and outdoor projections, rearward pitch, rear grille and supports.
Evidence for this model and installation
- Uni-Fit 2026 brochure — model specifications ↗Printed page 4 / PDF page 4: all ten UCT/UET B-series, final A-suffix R-32 models · Checked 2026-10-13
- Uni-Fit 2026 brochure — electrical requirements ↗Printed page 5 / PDF page 5: exact model groups, circuit/fuse ratings and NEMA plugs · Checked 2026-10-13
- Uni-Fit 2026 brochure — existing sleeve table ↗Printed page 6 / PDF page 6: explicitly named Friedrich WSE column; chassis dimensions and included decorative trim ring · Checked 2026-10-13
- Uni-Fit 2026 brochure — standard features ↗Printed page 3 / PDF page 3: built-in Wi-Fi and cooling/electric-heat series · Checked 2026-10-13
- Uni-Fit R-32 installation manual — WSE and preparation ↗Cover / PDF page 1 exact models; printed/PDF page 8 packing list; printed/PDF pages 14–16: WSE table, generic sleeve preparation, required rear grille, sealing and grounding · Checked 2026-10-13
- Uni-Fit R-32 installation manual — receptacles ↗Cover / PDF page 1 exact voltage groups; printed page 17 / PDF page 17, Table E.1: receptacle and circuit ratings for corresponding UCT/UET voltage groups · Checked 2026-10-13
- Uni-Fit 2026 — native sleeve and new installation ↗Printed page 6: USC/USEZ required for new installation, sold separately; combined sleeve outside dimensions 25-7/8 W x 15-1/2 H x 16-3/4 D in; finished-opening width 26-1/8 in differs from exact USEZ manual page 3 (26-1/4 in). Included trim ring. The combined table does not resolve the exact USEZ drawing conflict. · Checked 2026-11-11
- USEZ sleeve assembly and installation instructions ↗Printed pages 1, 3 and 5. Page 3 Figures 6–8 specify the assembled USEZ housing, minimum rough opening, projections and pitch for the sleeve covered by this exact manual. Page 5 shows sleeve components and rear grille. · Checked 2026-11-22
- Uni-Fit R-32 manual — supplied installation parts ↗Cover / PDF page 1 exact models; printed/PDF page 8 packing list; pages 14–16 provided dual-intake grille and installation methods · Checked 2026-10-13
- AJ Madison — exact UCT10B10A destination ↗Product heading and model identity only. Retailer specifications are not used as installation evidence; price and stock are not imported. · Checked 2026-10-13
- Abt — exact UCT10B10A store listing ↗Exact model # UCT10B10A; price in the product page and InStock on its Product offer. Delivery shown for test ZIP 60601 in the product page shipping control. · Checked 2026-11-22
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
Sleeve: Friedrich USC, Friedrich USEZ documented
Next check: Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Nominal supply
- 230 V
- Nominal cooling rating
- 10,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 6-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.1
Wi-Fi documented
Installation: Friedrich USC · required kit included; Friedrich USEZ · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC, Friedrich USEZ. Installation conditions apply.
Checks before purchase (6)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT10B30A at Abt ↗Store listing checked 2026-11-22 · $849.00 · Listed in stock · ZIP 60601: seller showed delivery · Confirm the sleeve and installation parts separately.
UCT10B30A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links with no affiliate commission. Check current price, parts and delivery for your ZIP directly with the seller.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
- Confirm the USEZ sleeve revision before cutting or reusing an opening. The October 1, 2024 USEZ installation drawing gives a minimum 26-1/4 × 15-3/4 in opening for the sleeve covered by that manual.
- For the USEZ covered by the October 1, 2024 manual, follow page 3 for minimum indoor and outdoor projections, rearward pitch, rear grille and supports.
Evidence for this model and installation
- Uni-Fit 2026 brochure — model specifications ↗Printed page 4 / PDF page 4: all ten UCT/UET B-series, final A-suffix R-32 models · Checked 2026-10-13
- Uni-Fit 2026 brochure — electrical requirements ↗Printed page 5 / PDF page 5: exact model groups, circuit/fuse ratings and NEMA plugs · Checked 2026-10-13
- Uni-Fit 2026 brochure — existing sleeve table ↗Printed page 6 / PDF page 6: explicitly named Friedrich WSE column; chassis dimensions and included decorative trim ring · Checked 2026-10-13
- Uni-Fit 2026 brochure — standard features ↗Printed page 3 / PDF page 3: built-in Wi-Fi and cooling/electric-heat series · Checked 2026-10-13
- Uni-Fit R-32 installation manual — WSE and preparation ↗Cover / PDF page 1 exact models; printed/PDF page 8 packing list; printed/PDF pages 14–16: WSE table, generic sleeve preparation, required rear grille, sealing and grounding · Checked 2026-10-13
- Uni-Fit R-32 installation manual — receptacles ↗Cover / PDF page 1 exact voltage groups; printed page 17 / PDF page 17, Table E.1: receptacle and circuit ratings for corresponding UCT/UET voltage groups · Checked 2026-10-13
- Uni-Fit 2026 — native sleeve and new installation ↗Printed page 6: USC/USEZ required for new installation, sold separately; combined sleeve outside dimensions 25-7/8 W x 15-1/2 H x 16-3/4 D in; finished-opening width 26-1/8 in differs from exact USEZ manual page 3 (26-1/4 in). Included trim ring. The combined table does not resolve the exact USEZ drawing conflict. · Checked 2026-11-11
- USEZ sleeve assembly and installation instructions ↗Printed pages 1, 3 and 5. Page 3 Figures 6–8 specify the assembled USEZ housing, minimum rough opening, projections and pitch for the sleeve covered by this exact manual. Page 5 shows sleeve components and rear grille. · Checked 2026-11-22
- Uni-Fit R-32 manual — supplied installation parts ↗Cover / PDF page 1 exact models; printed/PDF page 8 packing list; pages 14–16 provided dual-intake grille and installation methods · Checked 2026-10-13
- AJ Madison — exact UCT10B30A destination ↗Product heading and model identity only. Retailer specifications are not used as installation evidence; price and stock are not imported. · Checked 2026-10-13
- Abt — exact UCT10B30A store listing ↗Exact model # UCT10B30A; price in the product page and InStock on its Product offer. Delivery shown for test ZIP 60601 in the product page shipping control. · Checked 2026-11-22
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
Sleeve: Friedrich USC, Friedrich USEZ documented
Next check: Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Nominal supply
- 115 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10
Wi-Fi documented
Installation: Friedrich USC · required kit included; Friedrich USEZ · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC, Friedrich USEZ. Installation conditions apply.
Checks before purchase (6)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT12B10A at Abt ↗Store listing checked 2026-11-22 · $949.00 · Listed in stock · ZIP 60601: seller showed delivery · Confirm the sleeve and installation parts separately.
UCT12B10A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links with no affiliate commission. Check current price, parts and delivery for your ZIP directly with the seller.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
- Confirm the USEZ sleeve revision before cutting or reusing an opening. The October 1, 2024 USEZ installation drawing gives a minimum 26-1/4 × 15-3/4 in opening for the sleeve covered by that manual.
- For the USEZ covered by the October 1, 2024 manual, follow page 3 for minimum indoor and outdoor projections, rearward pitch, rear grille and supports.
Evidence for this model and installation
- Uni-Fit 2026 brochure — model specifications ↗Printed page 4 / PDF page 4: all ten UCT/UET B-series, final A-suffix R-32 models · Checked 2026-10-13
- Uni-Fit 2026 brochure — electrical requirements ↗Printed page 5 / PDF page 5: exact model groups, circuit/fuse ratings and NEMA plugs · Checked 2026-10-13
- Uni-Fit 2026 brochure — existing sleeve table ↗Printed page 6 / PDF page 6: explicitly named Friedrich WSE column; chassis dimensions and included decorative trim ring · Checked 2026-10-13
- Uni-Fit 2026 brochure — standard features ↗Printed page 3 / PDF page 3: built-in Wi-Fi and cooling/electric-heat series · Checked 2026-10-13
- Uni-Fit R-32 installation manual — WSE and preparation ↗Cover / PDF page 1 exact models; printed/PDF page 8 packing list; printed/PDF pages 14–16: WSE table, generic sleeve preparation, required rear grille, sealing and grounding · Checked 2026-10-13
- Uni-Fit R-32 installation manual — receptacles ↗Cover / PDF page 1 exact voltage groups; printed page 17 / PDF page 17, Table E.1: receptacle and circuit ratings for corresponding UCT/UET voltage groups · Checked 2026-10-13
- Uni-Fit 2026 — native sleeve and new installation ↗Printed page 6: USC/USEZ required for new installation, sold separately; combined sleeve outside dimensions 25-7/8 W x 15-1/2 H x 16-3/4 D in; finished-opening width 26-1/8 in differs from exact USEZ manual page 3 (26-1/4 in). Included trim ring. The combined table does not resolve the exact USEZ drawing conflict. · Checked 2026-11-11
- USEZ sleeve assembly and installation instructions ↗Printed pages 1, 3 and 5. Page 3 Figures 6–8 specify the assembled USEZ housing, minimum rough opening, projections and pitch for the sleeve covered by this exact manual. Page 5 shows sleeve components and rear grille. · Checked 2026-11-22
- Uni-Fit R-32 manual — supplied installation parts ↗Cover / PDF page 1 exact models; printed/PDF page 8 packing list; pages 14–16 provided dual-intake grille and installation methods · Checked 2026-10-13
- AJ Madison — exact UCT12B10A destination ↗Product heading and model identity only. Retailer specifications are not used as installation evidence; price and stock are not imported. · Checked 2026-10-13
- Abt — exact UCT12B10A store listing ↗Exact model # UCT12B10A; price in the product page and InStock on its Product offer. Delivery shown for test ZIP 60601 in the product page shipping control. · Checked 2026-11-22
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
Sleeve: Friedrich USC, Friedrich USEZ documented
Next check: Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 6-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10
Wi-Fi documented
Installation: Friedrich USC · required kit included; Friedrich USEZ · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC, Friedrich USEZ. Installation conditions apply.
Checks before purchase (6)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT12B30A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links with no affiliate commission. Check current price, parts and delivery for your ZIP directly with the seller.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
- Confirm the USEZ sleeve revision before cutting or reusing an opening. The October 1, 2024 USEZ installation drawing gives a minimum 26-1/4 × 15-3/4 in opening for the sleeve covered by that manual.
- For the USEZ covered by the October 1, 2024 manual, follow page 3 for minimum indoor and outdoor projections, rearward pitch, rear grille and supports.
Evidence for this model and installation
- Uni-Fit 2026 brochure — model specifications ↗Printed page 4 / PDF page 4: all ten UCT/UET B-series, final A-suffix R-32 models · Checked 2026-10-13
- Uni-Fit 2026 brochure — electrical requirements ↗Printed page 5 / PDF page 5: exact model groups, circuit/fuse ratings and NEMA plugs · Checked 2026-10-13
- Uni-Fit 2026 brochure — existing sleeve table ↗Printed page 6 / PDF page 6: explicitly named Friedrich WSE column; chassis dimensions and included decorative trim ring · Checked 2026-10-13
- Uni-Fit 2026 brochure — standard features ↗Printed page 3 / PDF page 3: built-in Wi-Fi and cooling/electric-heat series · Checked 2026-10-13
- Uni-Fit R-32 installation manual — WSE and preparation ↗Cover / PDF page 1 exact models; printed/PDF page 8 packing list; printed/PDF pages 14–16: WSE table, generic sleeve preparation, required rear grille, sealing and grounding · Checked 2026-10-13
- Uni-Fit R-32 installation manual — receptacles ↗Cover / PDF page 1 exact voltage groups; printed page 17 / PDF page 17, Table E.1: receptacle and circuit ratings for corresponding UCT/UET voltage groups · Checked 2026-10-13
- Uni-Fit 2026 — native sleeve and new installation ↗Printed page 6: USC/USEZ required for new installation, sold separately; combined sleeve outside dimensions 25-7/8 W x 15-1/2 H x 16-3/4 D in; finished-opening width 26-1/8 in differs from exact USEZ manual page 3 (26-1/4 in). Included trim ring. The combined table does not resolve the exact USEZ drawing conflict. · Checked 2026-11-11
- USEZ sleeve assembly and installation instructions ↗Printed pages 1, 3 and 5. Page 3 Figures 6–8 specify the assembled USEZ housing, minimum rough opening, projections and pitch for the sleeve covered by this exact manual. Page 5 shows sleeve components and rear grille. · Checked 2026-11-22
- Uni-Fit R-32 manual — supplied installation parts ↗Cover / PDF page 1 exact models; printed/PDF page 8 packing list; pages 14–16 provided dual-intake grille and installation methods · Checked 2026-10-13
- AJ Madison — exact UCT12B30A destination ↗Product heading and model identity only. Retailer specifications are not used as installation evidence; price and stock are not imported. · Checked 2026-10-13
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
Sleeve: Friedrich USC, Friedrich USEZ documented
Next check: Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Nominal supply
- 230 V
- Nominal cooling rating
- 14,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 6-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 9.3
Wi-Fi documented
Installation: Friedrich USC · required kit included; Friedrich USEZ · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC, Friedrich USEZ. Installation conditions apply.
Checks before purchase (6)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT14B30A at Total Home Supply ↗Store listing checked 2026-11-22 · $999.00 · Listed out of stock · Confirm the sleeve and installation parts separately.
UCT14B30A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links with no affiliate commission. Check current price, parts and delivery for your ZIP directly with the seller.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
- Confirm the USEZ sleeve revision before cutting or reusing an opening. The October 1, 2024 USEZ installation drawing gives a minimum 26-1/4 × 15-3/4 in opening for the sleeve covered by that manual.
- For the USEZ covered by the October 1, 2024 manual, follow page 3 for minimum indoor and outdoor projections, rearward pitch, rear grille and supports.
Evidence for this model and installation
- Uni-Fit 2026 brochure — model specifications ↗Printed page 4 / PDF page 4: all ten UCT/UET B-series, final A-suffix R-32 models · Checked 2026-10-13
- Uni-Fit 2026 brochure — electrical requirements ↗Printed page 5 / PDF page 5: exact model groups, circuit/fuse ratings and NEMA plugs · Checked 2026-10-13
- Uni-Fit 2026 brochure — existing sleeve table ↗Printed page 6 / PDF page 6: explicitly named Friedrich WSE column; chassis dimensions and included decorative trim ring · Checked 2026-10-13
- Uni-Fit 2026 brochure — standard features ↗Printed page 3 / PDF page 3: built-in Wi-Fi and cooling/electric-heat series · Checked 2026-10-13
- Uni-Fit R-32 installation manual — WSE and preparation ↗Cover / PDF page 1 exact models; printed/PDF page 8 packing list; printed/PDF pages 14–16: WSE table, generic sleeve preparation, required rear grille, sealing and grounding · Checked 2026-10-13
- Uni-Fit R-32 installation manual — receptacles ↗Cover / PDF page 1 exact voltage groups; printed page 17 / PDF page 17, Table E.1: receptacle and circuit ratings for corresponding UCT/UET voltage groups · Checked 2026-10-13
- Uni-Fit 2026 — native sleeve and new installation ↗Printed page 6: USC/USEZ required for new installation, sold separately; combined sleeve outside dimensions 25-7/8 W x 15-1/2 H x 16-3/4 D in; finished-opening width 26-1/8 in differs from exact USEZ manual page 3 (26-1/4 in). Included trim ring. The combined table does not resolve the exact USEZ drawing conflict. · Checked 2026-11-11
- USEZ sleeve assembly and installation instructions ↗Printed pages 1, 3 and 5. Page 3 Figures 6–8 specify the assembled USEZ housing, minimum rough opening, projections and pitch for the sleeve covered by this exact manual. Page 5 shows sleeve components and rear grille. · Checked 2026-11-22
- Uni-Fit R-32 manual — supplied installation parts ↗Cover / PDF page 1 exact models; printed/PDF page 8 packing list; pages 14–16 provided dual-intake grille and installation methods · Checked 2026-10-13
- AJ Madison — exact UCT14B30A destination ↗Product heading and model identity only. Retailer specifications are not used as installation evidence; price and stock are not imported. · Checked 2026-10-13
- Total Home Supply — exact UCT14B30A store listing ↗Exact SKU FRIEDRICH-UCT14B30A; product page shows the price and asks customers to call for availability. · Checked 2026-11-22
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
Sleeve: Friedrich USC, Friedrich USEZ documented
Next check: Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Nominal supply
- 115 V
- Nominal cooling rating
- 8,000 BTU/h
- Heating
- Electric heat
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 9.6
Wi-Fi documented
Installation: Friedrich USC · required kit included; Friedrich USEZ · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC, Friedrich USEZ. Installation conditions apply.
Checks before purchase (6)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UET08B11A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links with no affiliate commission. Check current price, parts and delivery for your ZIP directly with the seller.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
- Confirm the USEZ sleeve revision before cutting or reusing an opening. The October 1, 2024 USEZ installation drawing gives a minimum 26-1/4 × 15-3/4 in opening for the sleeve covered by that manual.
- For the USEZ covered by the October 1, 2024 manual, follow page 3 for minimum indoor and outdoor projections, rearward pitch, rear grille and supports.
Evidence for this model and installation
- Uni-Fit 2026 brochure — model specifications ↗Printed page 4 / PDF page 4: all ten UCT/UET B-series, final A-suffix R-32 models · Checked 2026-10-13
- Uni-Fit 2026 brochure — electrical requirements ↗Printed page 5 / PDF page 5: exact model groups, circuit/fuse ratings and NEMA plugs · Checked 2026-10-13
- Uni-Fit 2026 brochure — existing sleeve table ↗Printed page 6 / PDF page 6: explicitly named Friedrich WSE column; chassis dimensions and included decorative trim ring · Checked 2026-10-13
- Uni-Fit 2026 brochure — standard features ↗Printed page 3 / PDF page 3: built-in Wi-Fi and cooling/electric-heat series · Checked 2026-10-13
- Uni-Fit R-32 installation manual — WSE and preparation ↗Cover / PDF page 1 exact models; printed/PDF page 8 packing list; printed/PDF pages 14–16: WSE table, generic sleeve preparation, required rear grille, sealing and grounding · Checked 2026-10-13
- Uni-Fit R-32 installation manual — receptacles ↗Cover / PDF page 1 exact voltage groups; printed page 17 / PDF page 17, Table E.1: receptacle and circuit ratings for corresponding UCT/UET voltage groups · Checked 2026-10-13
- Uni-Fit 2026 — native sleeve and new installation ↗Printed page 6: USC/USEZ required for new installation, sold separately; combined sleeve outside dimensions 25-7/8 W x 15-1/2 H x 16-3/4 D in; finished-opening width 26-1/8 in differs from exact USEZ manual page 3 (26-1/4 in). Included trim ring. The combined table does not resolve the exact USEZ drawing conflict. · Checked 2026-11-11
- USEZ sleeve assembly and installation instructions ↗Printed pages 1, 3 and 5. Page 3 Figures 6–8 specify the assembled USEZ housing, minimum rough opening, projections and pitch for the sleeve covered by this exact manual. Page 5 shows sleeve components and rear grille. · Checked 2026-11-22
- Uni-Fit R-32 manual — supplied installation parts ↗Cover / PDF page 1 exact models; printed/PDF page 8 packing list; pages 14–16 provided dual-intake grille and installation methods · Checked 2026-10-13
- AJ Madison — exact UET08B11A destination ↗Product heading and model identity only. Retailer specifications are not used as installation evidence; price and stock are not imported. · Checked 2026-10-13
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
Sleeve: Friedrich USC, Friedrich USEZ documented
Next check: Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Nominal supply
- 230 V
- Nominal cooling rating
- 10,000 BTU/h
- Heating
- Electric heat
- Plug
- NEMA 6-20P
- Specified circuit / fuse
- 20 A
- CEER (nominal rating)
- 9.6
Wi-Fi documented
Installation: Friedrich USC · required kit included; Friedrich USEZ · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC, Friedrich USEZ. Installation conditions apply.
Checks before purchase (6)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UET10B33A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links with no affiliate commission. Check current price, parts and delivery for your ZIP directly with the seller.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
- Confirm the USEZ sleeve revision before cutting or reusing an opening. The October 1, 2024 USEZ installation drawing gives a minimum 26-1/4 × 15-3/4 in opening for the sleeve covered by that manual.
- For the USEZ covered by the October 1, 2024 manual, follow page 3 for minimum indoor and outdoor projections, rearward pitch, rear grille and supports.
Evidence for this model and installation
- Uni-Fit 2026 brochure — model specifications ↗Printed page 4 / PDF page 4: all ten UCT/UET B-series, final A-suffix R-32 models · Checked 2026-10-13
- Uni-Fit 2026 brochure — electrical requirements ↗Printed page 5 / PDF page 5: exact model groups, circuit/fuse ratings and NEMA plugs · Checked 2026-10-13
- Uni-Fit 2026 brochure — existing sleeve table ↗Printed page 6 / PDF page 6: explicitly named Friedrich WSE column; chassis dimensions and included decorative trim ring · Checked 2026-10-13
- Uni-Fit 2026 brochure — standard features ↗Printed page 3 / PDF page 3: built-in Wi-Fi and cooling/electric-heat series · Checked 2026-10-13
- Uni-Fit R-32 installation manual — WSE and preparation ↗Cover / PDF page 1 exact models; printed/PDF page 8 packing list; printed/PDF pages 14–16: WSE table, generic sleeve preparation, required rear grille, sealing and grounding · Checked 2026-10-13
- Uni-Fit R-32 installation manual — receptacles ↗Cover / PDF page 1 exact voltage groups; printed page 17 / PDF page 17, Table E.1: receptacle and circuit ratings for corresponding UCT/UET voltage groups · Checked 2026-10-13
- Uni-Fit 2026 — native sleeve and new installation ↗Printed page 6: USC/USEZ required for new installation, sold separately; combined sleeve outside dimensions 25-7/8 W x 15-1/2 H x 16-3/4 D in; finished-opening width 26-1/8 in differs from exact USEZ manual page 3 (26-1/4 in). Included trim ring. The combined table does not resolve the exact USEZ drawing conflict. · Checked 2026-11-11
- USEZ sleeve assembly and installation instructions ↗Printed pages 1, 3 and 5. Page 3 Figures 6–8 specify the assembled USEZ housing, minimum rough opening, projections and pitch for the sleeve covered by this exact manual. Page 5 shows sleeve components and rear grille. · Checked 2026-11-22
- Uni-Fit R-32 manual — supplied installation parts ↗Cover / PDF page 1 exact models; printed/PDF page 8 packing list; pages 14–16 provided dual-intake grille and installation methods · Checked 2026-10-13
- AJ Madison — exact UET10B33A destination ↗Product heading and model identity only. Retailer specifications are not used as installation evidence; price and stock are not imported. · Checked 2026-10-13
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
Sleeve: Friedrich USC, Friedrich USEZ documented
Next check: Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Electric heat
- Plug
- NEMA 6-20P
- Specified circuit / fuse
- 20 A
- CEER (nominal rating)
- 9.6
Wi-Fi documented
Installation: Friedrich USC · required kit included; Friedrich USEZ · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC, Friedrich USEZ. Installation conditions apply.
Checks before purchase (6)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UET12B33A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links with no affiliate commission. Check current price, parts and delivery for your ZIP directly with the seller.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
- Confirm the USEZ sleeve revision before cutting or reusing an opening. The October 1, 2024 USEZ installation drawing gives a minimum 26-1/4 × 15-3/4 in opening for the sleeve covered by that manual.
- For the USEZ covered by the October 1, 2024 manual, follow page 3 for minimum indoor and outdoor projections, rearward pitch, rear grille and supports.
Evidence for this model and installation
- Uni-Fit 2026 brochure — model specifications ↗Printed page 4 / PDF page 4: all ten UCT/UET B-series, final A-suffix R-32 models · Checked 2026-10-13
- Uni-Fit 2026 brochure — electrical requirements ↗Printed page 5 / PDF page 5: exact model groups, circuit/fuse ratings and NEMA plugs · Checked 2026-10-13
- Uni-Fit 2026 brochure — existing sleeve table ↗Printed page 6 / PDF page 6: explicitly named Friedrich WSE column; chassis dimensions and included decorative trim ring · Checked 2026-10-13
- Uni-Fit 2026 brochure — standard features ↗Printed page 3 / PDF page 3: built-in Wi-Fi and cooling/electric-heat series · Checked 2026-10-13
- Uni-Fit R-32 installation manual — WSE and preparation ↗Cover / PDF page 1 exact models; printed/PDF page 8 packing list; printed/PDF pages 14–16: WSE table, generic sleeve preparation, required rear grille, sealing and grounding · Checked 2026-10-13
- Uni-Fit R-32 installation manual — receptacles ↗Cover / PDF page 1 exact voltage groups; printed page 17 / PDF page 17, Table E.1: receptacle and circuit ratings for corresponding UCT/UET voltage groups · Checked 2026-10-13
- Uni-Fit 2026 — native sleeve and new installation ↗Printed page 6: USC/USEZ required for new installation, sold separately; combined sleeve outside dimensions 25-7/8 W x 15-1/2 H x 16-3/4 D in; finished-opening width 26-1/8 in differs from exact USEZ manual page 3 (26-1/4 in). Included trim ring. The combined table does not resolve the exact USEZ drawing conflict. · Checked 2026-11-11
- USEZ sleeve assembly and installation instructions ↗Printed pages 1, 3 and 5. Page 3 Figures 6–8 specify the assembled USEZ housing, minimum rough opening, projections and pitch for the sleeve covered by this exact manual. Page 5 shows sleeve components and rear grille. · Checked 2026-11-22
- Uni-Fit R-32 manual — supplied installation parts ↗Cover / PDF page 1 exact models; printed/PDF page 8 packing list; pages 14–16 provided dual-intake grille and installation methods · Checked 2026-10-13
- AJ Madison — exact UET12B33A destination ↗Product heading and model identity only. Retailer specifications are not used as installation evidence; price and stock are not imported. · Checked 2026-10-13
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
Sleeve: Friedrich USC, Friedrich USEZ documented
Next check: Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Nominal supply
- 230 V
- Nominal cooling rating
- 14,000 BTU/h
- Heating
- Electric heat
- Plug
- NEMA 6-20P
- Specified circuit / fuse
- 20 A
- CEER (nominal rating)
- 9.3
Wi-Fi documented
Installation: Friedrich USC · required kit included; Friedrich USEZ · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC, Friedrich USEZ. Installation conditions apply.
Checks before purchase (6)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UET14B33A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links with no affiliate commission. Check current price, parts and delivery for your ZIP directly with the seller.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
- Confirm the USEZ sleeve revision before cutting or reusing an opening. The October 1, 2024 USEZ installation drawing gives a minimum 26-1/4 × 15-3/4 in opening for the sleeve covered by that manual.
- For the USEZ covered by the October 1, 2024 manual, follow page 3 for minimum indoor and outdoor projections, rearward pitch, rear grille and supports.
Evidence for this model and installation
- Uni-Fit 2026 brochure — model specifications ↗Printed page 4 / PDF page 4: all ten UCT/UET B-series, final A-suffix R-32 models · Checked 2026-10-13
- Uni-Fit 2026 brochure — electrical requirements ↗Printed page 5 / PDF page 5: exact model groups, circuit/fuse ratings and NEMA plugs · Checked 2026-10-13
- Uni-Fit 2026 brochure — existing sleeve table ↗Printed page 6 / PDF page 6: explicitly named Friedrich WSE column; chassis dimensions and included decorative trim ring · Checked 2026-10-13
- Uni-Fit 2026 brochure — standard features ↗Printed page 3 / PDF page 3: built-in Wi-Fi and cooling/electric-heat series · Checked 2026-10-13
- Uni-Fit R-32 installation manual — WSE and preparation ↗Cover / PDF page 1 exact models; printed/PDF page 8 packing list; printed/PDF pages 14–16: WSE table, generic sleeve preparation, required rear grille, sealing and grounding · Checked 2026-10-13
- Uni-Fit R-32 installation manual — receptacles ↗Cover / PDF page 1 exact voltage groups; printed page 17 / PDF page 17, Table E.1: receptacle and circuit ratings for corresponding UCT/UET voltage groups · Checked 2026-10-13
- Uni-Fit 2026 — native sleeve and new installation ↗Printed page 6: USC/USEZ required for new installation, sold separately; combined sleeve outside dimensions 25-7/8 W x 15-1/2 H x 16-3/4 D in; finished-opening width 26-1/8 in differs from exact USEZ manual page 3 (26-1/4 in). Included trim ring. The combined table does not resolve the exact USEZ drawing conflict. · Checked 2026-11-11
- USEZ sleeve assembly and installation instructions ↗Printed pages 1, 3 and 5. Page 3 Figures 6–8 specify the assembled USEZ housing, minimum rough opening, projections and pitch for the sleeve covered by this exact manual. Page 5 shows sleeve components and rear grille. · Checked 2026-11-22
- Uni-Fit R-32 manual — supplied installation parts ↗Cover / PDF page 1 exact models; printed/PDF page 8 packing list; pages 14–16 provided dual-intake grille and installation methods · Checked 2026-10-13
- AJ Madison — exact UET14B33A destination ↗Product heading and model identity only. Retailer specifications are not used as installation evidence; price and stock are not imported. · Checked 2026-10-13
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
Sleeve: Friedrich WSE documented
Next check: Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Nominal supply
- 115 V
- Nominal cooling rating
- Not established
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- Not established
Inverter documentedWi-Fi documented
Installation: Friedrich WSE · follow listed conditions
What matches (1)
- Documented sleeve option: Friedrich WSE. Installation conditions apply.
Checks before purchase (6)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Seller availability unverified for this exact model.
Sleeves, required parts and sources
Friedrich WSE
Manufacturer sleeve association; listed conditions apply.
External condensate drain kit (DK) · Optional or conditional · Package inclusion not established
- Confirm an actual WSE sleeve in serviceable condition. The exact B-suffix model appears in the brochure's installation table, whose note requires a WSE sleeve; dimensions alone are not the evidence for this relation.
- Verify the rear grille against the manufacturer installation requirements. Incorrect airflow can recirculate discharge air and cause shutdown; do not assume an old grille is suitable.
- Check the actual installation for this 115 V model, NEMA 5-15P plug and manufacturer-specified 15 A circuit/fuse. Cooling running current is a separate specification.
- DK is an optional external drain kit when connection to a condensate disposal system is necessary or desired. It is not a general requirement for every WSE replacement.
Evidence for this model and installation
- WallMaster 2026 brochure — exact model specifications ↗Printed page 5 / PDF page 5: inverter model specifications and model sizing list · Checked 2026-10-12
- WallMaster 2026 brochure — chassis and WSE sleeve ↗Printed page 6 / PDF page 6: chassis, sleeve and finished-hole tables; WSE requirement · Checked 2026-10-13
- WallMaster 2026 brochure — electrical requirements ↗Printed page 6 / PDF page 6: exact B-suffix model groups, circuit/fuse ratings and NEMA plugs · Checked 2026-10-12
- WallMaster 2026 brochure — grilles and drain kits ↗Printed page 7 / PDF page 7: WSE, WSEZ, rear grille orientation, DK/IDK and BAK conditions · Checked 2026-10-13
- WallMaster 2026 brochure — standard features ↗Printed page 8 / PDF page 8: compressor type and built-in Wi-Fi; broad performance ranges are not used as model specifications · Checked 2026-10-12
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
- Friedrich WallMaster 2027 brochure, preliminary specifications ↗Printed page 5 / PDF page 5, 115 V WCVT12B10B row in the Preliminary Specifications table: 11,800 BTU/h, 12.4 A and CEER 13.9. Page 6 gives the sleeve and circuit table. · Checked 2026-11-22
2026 WallMaster inverter / R-32, final B suffix (BR_WM_REV 07-15-25)
Manufacturer specifications ↗More checks neededFriedrich
Sleeve: Friedrich WSE documented
Next check: Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Nominal supply
- 230 V
- Nominal cooling rating
- 16,800 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 6-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 12.6
Inverter documentedWi-Fi documented
Installation: Friedrich WSE · follow listed conditions
What matches (1)
- Documented sleeve option: Friedrich WSE. Installation conditions apply.
Checks before purchase (6)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- No undisputed indoor noise rating is available.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
WCVT16B30B at Total Home Supply ↗Store listing checked 2026-11-22 · $1,449.00 · Listed out of stock · AC listing; new-installation sleeve sold separately
Ordinary store links with no affiliate commission. Check current price, parts and delivery for your ZIP directly with the seller.
Sleeves, required parts and sources
Friedrich WSE
Manufacturer sleeve association; listed conditions apply.
External condensate drain kit (DK) · Optional or conditional · Package inclusion not established
- Confirm an actual WSE sleeve in serviceable condition. The exact B-suffix model appears in the brochure's installation table, whose note requires a WSE sleeve; dimensions alone are not the evidence for this relation.
- Verify the rear grille against the manufacturer installation requirements. Incorrect airflow can recirculate discharge air and cause shutdown; do not assume an old grille is suitable.
- Check the actual installation for this 230 V model, NEMA 6-15P plug and manufacturer-specified 15 A circuit/fuse. Cooling running current is a separate specification.
- DK is an optional external drain kit when connection to a condensate disposal system is necessary or desired. It is not a general requirement for every WSE replacement.
Evidence for this model and installation
2026 WallMaster inverter / R-32, final B suffix (BR_WM_REV 07-15-25)
Manufacturer specifications ↗