Updated from the reviewed catalog: 14 document 115 V operation; 0 need verification of that requirement. Your room, actual supply, sleeve and required parts still need confirmation. This is not a ranking or installation approval.
More checks neededGE
- Nominal supply
- 115 V
- Nominal cooling rating
- 7,800 BTU/h
- Heating
- Cooling only
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 10.6
Inverter documentedWi-Fi documented
Installation: GE RAB26A · required kit included; GE RAB46B · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (2)
- Documented sleeve option: GE RAB26A, GE RAB46B. Installation conditions apply.
- 115 V operation is documented.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (4)
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
GE RAB26A
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB26A with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
GE RAB46B
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB46B with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
Evidence for this model and installation
- GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
- GE AJCQ08AXXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AJCQ08AXXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- GE projected Quick Specs — AJCQ08AXXWA, AJCQ12AXXWA ↗Single-page exact-model sheet: drawing, CEER and plug/circuit rows; explicitly marked Projected specifications — subject to change. Not final electrical evidence. · Checked 2026-10-12
2025/2026 inverter generation; exact full SKU covered by 49-5001195
Manufacturer specifications ↗More checks neededGE
- Nominal supply
- 115 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 10.5
Inverter documentedWi-Fi documented
Installation: GE RAB26A · required kit included; GE RAB46B · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (2)
- Documented sleeve option: GE RAB26A, GE RAB46B. Installation conditions apply.
- 115 V operation is documented.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (4)
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
GE RAB26A
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB26A with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
GE RAB46B
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB46B with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
Evidence for this model and installation
- GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
- GE AJCQ12AXXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AJCQ12AXXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- GE projected Quick Specs — AJCQ08AXXWA, AJCQ12AXXWA ↗Single-page exact-model sheet: drawing, CEER and plug/circuit rows; explicitly marked Projected specifications — subject to change. Not final electrical evidence. · Checked 2026-10-12
- GE AJCQ12AXXWA — conflicting FEATURES EER ↗Specs & Details > FEATURES > EER: 10.6. CAPACITY > Cooling EER in the same page reports 10.5. These are two section citations, not independent documents. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001195
Manufacturer specifications ↗More checks neededGE
- Nominal supply
- 115 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Heat pump with electric backup
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.6
Inverter documentedWi-Fi documented
Installation: GE RAB26A · required kit included; GE RAB46B · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (2)
- Documented sleeve option: GE RAB26A, GE RAB46B. Installation conditions apply.
- 115 V operation is documented.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (4)
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
GE RAB26A
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB26A with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
- For heat-capable models, apply all page-16 combustible-material clearances: sides 1 in, front and exterior rear 20 in, above 39-3/8 in, below as the manual’s 4-7/8–6-3/8 in range. Resolve the applicable bottom clearance for the actual installation; do not select an endpoint as a general rule.
GE RAB46B
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB46B with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
- For heat-capable models, apply all page-16 combustible-material clearances: sides 1 in, front and exterior rear 20 in, above 39-3/8 in, below as the manual’s 4-7/8–6-3/8 in range. Resolve the applicable bottom clearance for the actual installation; do not select an endpoint as a general rule.
Evidence for this model and installation
- GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
- GE AJVQ12ACXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AJVQ12ACXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001195
Manufacturer specifications ↗More checks neededGE
- Nominal supply
- 115 V
- Nominal cooling rating
- 7,800 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.6
Inverter documented
Installation: GE RAB24 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (2)
- Documented sleeve option: GE RAB24. Installation conditions apply.
- 115 V operation is documented.
Verify circuit ratingWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (4)
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
GE RAB24
Manufacturer sleeve association; listed conditions apply.
Supplied grille, seals, trim, grounding wire and 24-inch security brackets; use applicable parts · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB24 with the supplied stamped aluminum outdoor grille.
- Use the 24-inch sleeve brackets and the applicable sealing, grounding, grille and trim procedures on printed pages 15–24.
- Confirm exact nameplate, grounded outlet and circuit; the sleeve association does not prove electrical suitability.
- RAB24 sleeve is purchased separately; supplied trim/installation hardware is not a wall sleeve.
- Use the applicable sleeve procedure: secure sound housing, required rearward slope, supplied grounding wire with toothed washers, seals and trim; do not leave required hardware unused.
- Use the supplied 24-inch brackets for RAB24 or 26-inch brackets for RAB26A, with flanges behind the sleeve edge; attach both sides as specified on page 24.
Evidence for this model and installation
- GE 24-inch inverter owner and installation manual ↗Cover lists all four exact AK models and INVERTER. Printed/PDF pages 15–19 and 23–24: bare chassis, RAB24/RAB26A, supplied hardware, rearward slope, grounding, GE rear grille, trim and correct 24/26-inch security brackets. RAB26A recommendation spells RAG13 (not RAG13A). No numeric branch-circuit requirement. · Checked 2026-10-13
- GE AKCQ08AXXXA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AKCQ08AXXXA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
- GE AKCQ08AXXXA — conflicting FEATURES EER ↗Specs & Details > FEATURES > EER: 9.6. CAPACITY > Cooling EER in the same page reports 10.6. These are two section citations, not independent documents. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001293
Manufacturer specifications ↗More checks neededGE
- Nominal supply
- 115 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.5
Inverter documented
Installation: GE RAB24 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (2)
- Documented sleeve option: GE RAB24. Installation conditions apply.
- 115 V operation is documented.
Verify circuit ratingWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (4)
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
GE RAB24
Manufacturer sleeve association; listed conditions apply.
Supplied grille, seals, trim, grounding wire and 24-inch security brackets; use applicable parts · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB24 with the supplied stamped aluminum outdoor grille.
- Use the 24-inch sleeve brackets and the applicable sealing, grounding, grille and trim procedures on printed pages 15–24.
- Confirm exact nameplate, grounded outlet and circuit; the sleeve association does not prove electrical suitability.
- RAB24 sleeve is purchased separately; supplied trim/installation hardware is not a wall sleeve.
- Use the applicable sleeve procedure: secure sound housing, required rearward slope, supplied grounding wire with toothed washers, seals and trim; do not leave required hardware unused.
- Use the supplied 24-inch brackets for RAB24 or 26-inch brackets for RAB26A, with flanges behind the sleeve edge; attach both sides as specified on page 24.
Evidence for this model and installation
- GE 24-inch inverter owner and installation manual ↗Cover lists all four exact AK models and INVERTER. Printed/PDF pages 15–19 and 23–24: bare chassis, RAB24/RAB26A, supplied hardware, rearward slope, grounding, GE rear grille, trim and correct 24/26-inch security brackets. RAB26A recommendation spells RAG13 (not RAG13A). No numeric branch-circuit requirement. · Checked 2026-10-13
- GE AKCQ12AXXXA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AKCQ12AXXXA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
- GE AKCQ12AXXXA — conflicting FEATURES EER ↗Specs & Details > FEATURES > EER: 9.5. CAPACITY > Cooling EER in the same page reports 10.5. These are two section citations, not independent documents. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001293
Manufacturer specifications ↗More checks neededLG
- Nominal supply
- 115 V
- Nominal cooling rating
- 8,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.6
Reported indoor noise: 56 dBA (Manufacturer rating; fan speed and test conditions not stated). Test conditions vary by source.
What matches (1)
- 115 V operation is documented.
Checks before purchase (5)
- No positive manufacturer sleeve decision is available under these answers.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
LG AXSVA1
Sleeve decision needs review.
Provided installation hardware; apply exact sleeve procedure · Required for the listed procedure · Included as reported in source
- The current exact-model sheet does not name AXSVA1/AXSVA4. The associated manual describes an LGE sleeve and Procedure A. This generic description and matching dimensions do not establish this exact part/model relation.
- The model-associated manual supplies grille/insulation/shims/trim and describes LGE Procedure A. Follow the exact sleeve procedure and rearward slope; this is not independent evidence identifying this sleeve SKU.
LG AXSVA4
Sleeve decision needs review.
Provided installation hardware; apply exact sleeve procedure · Required for the listed procedure · Included as reported in source
- The current exact-model sheet does not name AXSVA1/AXSVA4. The associated manual describes an LGE sleeve and Procedure A. This generic description and matching dimensions do not establish this exact part/model relation.
- The model-associated manual supplies grille/insulation/shims/trim and describes LGE Procedure A. Follow the exact sleeve procedure and rearward slope; this is not independent evidence identifying this sleeve SKU.
Evidence for this model and installation
- LG US wall air conditioner category ↗Eleven LT equipment entries observed in initial category HTML; accessories excluded. Dynamic pagination is not proof of complete coverage. · Checked 2026-10-12
- LG owner manual — cool ↗Support associations checked 2026-10-12; visually reviewed 2026-10-13. Printed/PDF page 9 explicitly lists LT0816CER, LT1016CER, LT12124CNR (115 V) and LT1036CER, LT1236CER, LT1430CNR (230 V), 15 A circuit and outlet drawings; pages 11–13 packing list and LGE sleeve Procedure A. LT1216CER has a separate exact support manual. · Checked 2026-10-13
- LG LT0816CER — current product specifications ↗Specifications > Electrical Ratings, Performance, Features and Dimensions/Weight; public page specification data; product modelStatus ACTIVE checked separately from stock. · Checked 2026-10-13
- LG LT0816CER — exact support/document association ↗Selected support sales suffix and Download Manuals list; suffix is not automatically an alias of another physical generation. · Checked 2026-10-12
- LG LT0816CER — linked specification sheet ↗Exact SKU specifications, refrigerant and Optional Accessories. Dates differ across PDFs; older electrical/performance tables are not merged into current page values. · Checked 2026-10-12
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
Reviewed marketed SKU and UPC 048231379601; selected support LT0816CER.AT1AUSB. Base model is not an alias of every historical sales suffix.
Manufacturer specifications ↗More checks neededLG
- Nominal supply
- 115 V
- Nominal cooling rating
- 9,800 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.6
Installation: LG AXSVA1 · required kit included; LG AXSVA4 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
Reported indoor noise: 56 dBA (Manufacturer rating; fan speed and test conditions not stated). Test conditions vary by source.
What matches (2)
- Documented sleeve option: LG AXSVA1, LG AXSVA4. Installation conditions apply.
- 115 V operation is documented.
Checks before purchase (4)
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
LG AXSVA1
Manufacturer sleeve association; listed conditions apply.
Supplied installation parts: grille, applicable insulation, shims and trim; sleeve sold separately · Required for the listed procedure · Included as reported in source
- The current exact-UPC manufacturer sheet lists this sleeve as a separately sold optional accessory. Check the exact housing and model nameplate.
- Follow LGE sleeve Procedure A, including serviceable rear flange/grille, specified rearward slope, applicable supplied seals/shims and trim; sleeve is secured to the wall.
- 115 V model: use the documented 15 A circuit and matching grounded 5-15 plug/receptacle. Do not assume the existing outlet or circuit from the old unit.
LG AXSVA4
Manufacturer sleeve association; listed conditions apply.
Supplied installation parts: grille, applicable insulation, shims and trim; sleeve sold separately · Required for the listed procedure · Included as reported in source
- The current exact-UPC manufacturer sheet lists this sleeve as a separately sold optional accessory. Check the exact housing and model nameplate.
- Follow LGE sleeve Procedure A, including serviceable rear flange/grille, specified rearward slope, applicable supplied seals/shims and trim; sleeve is secured to the wall.
- 115 V model: use the documented 15 A circuit and matching grounded 5-15 plug/receptacle. Do not assume the existing outlet or circuit from the old unit.
Evidence for this model and installation
- LG US wall air conditioner category ↗Eleven LT equipment entries observed in initial category HTML; accessories excluded. Dynamic pagination is not proof of complete coverage. · Checked 2026-10-12
- LG owner manual — cool ↗Support associations checked 2026-10-12; visually reviewed 2026-10-13. Printed/PDF page 9 explicitly lists LT0816CER, LT1016CER, LT12124CNR (115 V) and LT1036CER, LT1236CER, LT1430CNR (230 V), 15 A circuit and outlet drawings; pages 11–13 packing list and LGE sleeve Procedure A. LT1216CER has a separate exact support manual. · Checked 2026-10-13
- LG LT1016CER — current product specifications ↗Specifications > Electrical Ratings, Performance, Features and Dimensions/Weight; public page specification data; product modelStatus ACTIVE checked separately from stock. · Checked 2026-10-13
- LG LT1016CER — exact support/document association ↗Selected support sales suffix and Download Manuals list; suffix is not automatically an alias of another physical generation. · Checked 2026-10-12
- LG LT1016CER — linked specification sheet ↗Exact SKU specifications, refrigerant and Optional Accessories. Dates differ across PDFs; older electrical/performance tables are not merged into current page values. · Checked 2026-10-12
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
Reviewed marketed SKU and UPC 048231379618; selected support LT1016CER.AT1AUSL. Base model is not an alias of every historical sales suffix.
Manufacturer specifications ↗More checks neededLG
- Nominal supply
- 115 V
- Nominal cooling rating
- 11,800 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.5
Reported indoor noise: 60 dBA (Manufacturer rating; fan speed and test conditions not stated). Test conditions vary by source.
What matches (1)
- 115 V operation is documented.
Checks before purchase (5)
- A manufacturer-documented sleeve for a new installation is not in this catalog.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
- LG US wall air conditioner category ↗Eleven LT equipment entries observed in initial category HTML; accessories excluded. Dynamic pagination is not proof of complete coverage. · Checked 2026-10-12
- LG owner manual — cool ↗Support associations checked 2026-10-12; visually reviewed 2026-10-13. Printed/PDF page 9 explicitly lists LT0816CER, LT1016CER, LT12124CNR (115 V) and LT1036CER, LT1236CER, LT1430CNR (230 V), 15 A circuit and outlet drawings; pages 11–13 packing list and LGE sleeve Procedure A. LT1216CER has a separate exact support manual. · Checked 2026-10-13
- LG LT12124CNR — current product specifications ↗Specifications > Electrical Ratings, Performance, Features and Dimensions/Weight; public page specification data; product modelStatus ACTIVE checked separately from stock. · Checked 2026-10-13
- LG LT12124CNR — exact support/document association ↗Selected support sales suffix and Download Manuals list; suffix is not automatically an alias of another physical generation. · Checked 2026-10-12
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
Reviewed marketed SKU and UPC 048231607261; selected support LT12124CNR.AT1AYOW. Base model is not an alias of every historical sales suffix.
Manufacturer specifications ↗More checks neededLG
- Nominal supply
- 115 V
- Nominal cooling rating
- 11,800 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.5
Reported indoor noise: 60 dBA (Manufacturer rating; fan speed and test conditions not stated). Test conditions vary by source.
What matches (1)
- 115 V operation is documented.
Checks before purchase (5)
- No positive manufacturer sleeve decision is available under these answers.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
LG AXSVA1
Sleeve decision needs review.
Provided installation hardware; apply exact sleeve procedure · Required for the listed procedure · Included as reported in source
- The current exact-model sheet does not name AXSVA1/AXSVA4. The associated manual describes an LGE sleeve and Procedure A. This generic description and matching dimensions do not establish this exact part/model relation.
- The model-associated manual supplies grille/insulation/shims/trim and describes LGE Procedure A. Follow the exact sleeve procedure and rearward slope; this is not independent evidence identifying this sleeve SKU.
LG AXSVA4
Sleeve decision needs review.
Provided installation hardware; apply exact sleeve procedure · Required for the listed procedure · Included as reported in source
- The current exact-model sheet does not name AXSVA1/AXSVA4. The associated manual describes an LGE sleeve and Procedure A. This generic description and matching dimensions do not establish this exact part/model relation.
- The model-associated manual supplies grille/insulation/shims/trim and describes LGE Procedure A. Follow the exact sleeve procedure and rearward slope; this is not independent evidence identifying this sleeve SKU.
Evidence for this model and installation
Reviewed marketed SKU and UPC 048231379632; selected support LT1216CER.AT1AHDS. Base model is not an alias of every historical sales suffix.
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 115 V
- Nominal cooling rating
- 8,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.1
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (2)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
- 115 V operation is documented.
Checks before purchase (4)
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT08B10A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Sleeve decision needs review.
Sources disagree on a fit-critical fact. This option cannot be a confirmed fit.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 115 V
- Nominal cooling rating
- 10,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.1
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (2)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
- 115 V operation is documented.
Checks before purchase (4)
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT10B10A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Sleeve decision needs review.
Sources disagree on a fit-critical fact. This option cannot be a confirmed fit.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 115 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (2)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
- 115 V operation is documented.
Checks before purchase (4)
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT12B10A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Sleeve decision needs review.
Sources disagree on a fit-critical fact. This option cannot be a confirmed fit.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 115 V
- Nominal cooling rating
- 8,000 BTU/h
- Heating
- Electric heat
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 9.6
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (2)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
- 115 V operation is documented.
Checks before purchase (4)
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UET08B11A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Sleeve decision needs review.
Sources disagree on a fit-critical fact. This option cannot be a confirmed fit.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 115 V
- Nominal cooling rating
- 13,500 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 13.2
Inverter documentedWi-Fi documented
Installation: Friedrich WSE · follow listed conditions
What matches (2)
- Documented sleeve option: Friedrich WSE. Installation conditions apply.
- 115 V operation is documented.
Checks before purchase (4)
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
Friedrich WSE
Manufacturer sleeve association; listed conditions apply.
External condensate drain kit (DK) · Optional or conditional · Package inclusion not established
- Confirm an actual WSE sleeve in serviceable condition. The exact B-suffix model appears in the brochure's installation table, whose note requires a WSE sleeve; dimensions alone are not the evidence for this relation.
- Verify the rear grille against the manufacturer installation requirements. Incorrect airflow can recirculate discharge air and cause shutdown; do not assume an old grille is suitable.
- Check the actual installation for this 115 V model, NEMA 5-15P plug and manufacturer-specified 15 A circuit/fuse. Cooling running current is a separate specification.
- DK is an optional external drain kit when connection to a condensate disposal system is necessary or desired. It is not a general requirement for every WSE replacement.
Evidence for this model and installation
2026 WallMaster inverter / R-32, final B suffix (BR_WM_REV 07-15-25)
Manufacturer specifications ↗