models

Friedrich WCVT12B10B

Friedrich documents this model for the WSE sleeve. The 2026 brochure and preliminary 2027 brochure give different cooling capacity, running current and efficiency for WCVT12B10B. Confirm the specs for the unit you are buying before sizing it to the room.

Reviewed 2026-11-22

Exact model: WCVT12B10BSource 1Source 2Source 3Source 5Source 135 · 2026 WallMaster inverter / R-32, final B suffix (BR_WM_REV 07-15-25)

Sources disagree

The 2026 brochure lists 13,500 BTU/h for cooling capacity; the preliminary 2027 table lists 11,800 BTU/h for the same WCVT12B10B at 115 V. Confirm the specific production unit.

Source 1Source 135

The 2026 brochure lists 13,500 BTU/h for cooling capacity; the preliminary 2027 table lists 11,800 BTU/h for the same WCVT12B10B at 115 V. Confirm the specific production unit.

Source 1Source 135

The 2026 brochure lists 11.6 A for running current; the preliminary 2027 table lists 12.4 A for the same WCVT12B10B at 115 V. Confirm the specific production unit.

Source 1Source 135

The 2026 brochure lists 11.6 A for running current; the preliminary 2027 table lists 12.4 A for the same WCVT12B10B at 115 V. Confirm the specific production unit.

Source 1Source 135

The 2026 brochure lists 13.2 for CEER; the preliminary 2027 table lists 13.9 for the same WCVT12B10B at 115 V. Confirm the specific production unit.

Source 1Source 135

The 2026 brochure lists 13.2 for CEER; the preliminary 2027 table lists 13.9 for the same WCVT12B10B at 115 V. Confirm the specific production unit.

Source 1Source 135
Voltage
115 VSource 1
Cooling capacity
Sources disagreeSource 1Source 135
Heating
Cooling onlySource 1
Rated cooling current
Sources disagreeSource 1Source 135
Specified circuit / fuse
15 ASource 3
Plug
NEMA 5-15PSource 3
Required receptacle
NEMA 5-15RSource 3Source 119
Inverter compressor
YesSource 5
Wi-Fi
YesSource 5
Chassis width
26.5 inSource 2
Chassis height
15.75 inSource 2
Chassis depth
21 inSource 2
Production status
currentSource 1
Seller availability
Not documented

Chassis measurements are descriptive. They do not establish sleeve compatibility. Production status and seller availability are checked separately.

Documented sleeve outcomes

A documented sleeve fit covers the physical combination under its listed conditions. Check electrical requirements separately before purchase.

Replacement options and documented installation requirements
ModelFit statusCoolingElectrical requirementsRequired / conditional partsWhat to check
Friedrich WCVT12B10B2026 WallMaster inverter / R-32, final B suffix (BR_WM_REV 07-15-25)Availability not checkedDocumented fit — conditions applySleeve: Friedrich WSESource 2Source 3Source 4Sources disagreeSource 1Source 135115 VSource 1PlugNEMA 5-15PSource 3ReceptacleNEMA 5-15RSource 3Source 119Specified circuit / fuse15 ASource 3
  • External condensate drain kitPart number: DKOnly if the stated condition appliesSource 4Package: Not documented
4 installation checks
  • Confirm an actual WSE sleeve in serviceable condition. The exact B-suffix model appears in the brochure's installation table, whose note requires a WSE sleeve; dimensions alone are not the evidence for this relation.Source 2
  • Verify the rear grille against the manufacturer installation requirements. Incorrect airflow can recirculate discharge air and cause shutdown; do not assume an old grille is suitable.Source 4
  • Check the actual installation for this 115 V model, NEMA 5-15P plug and manufacturer-specified 15 A circuit/fuse. Cooling running current is a separate specification.Source 1Source 3
  • DK is an optional external drain kit when connection to a condensate disposal system is necessary or desired. It is not a general requirement for every WSE replacement.Source 4

Manufacturer details ↗

Sources