← Back to models

models

Friedrich WCVT16B30B

Friedrich WCVT16B30B specifications and manufacturer-documented WSE installation. Confirm the exact unit manual, actual supply, grille and installation conditions before purchase.

Reviewed 2026-10-13

Exact model: WCVT16B30BSource 1Source 2Source 3Source 5 · 2026 WallMaster inverter / R-32, final B suffix (BR_WM_REV 07-15-25)

Voltage
230 VSource 1
Cooling capacity
16,800 BTU/hSource 1
Heating
Cooling onlySource 1
Rated cooling current
10.4 ASource 1
Specified circuit / fuse
15 ASource 3
Plug
NEMA 6-15PSource 3
Required receptacle
NEMA 6-15RSource 3Source 119
Inverter compressor
YesSource 5
Wi-Fi
YesSource 5
Chassis width
26.5 inSource 2
Chassis height
15.75 inSource 2
Chassis depth
21 inSource 2
Production status
currentSource 1
Seller availability
Not documented

Chassis measurements are descriptive. They do not establish sleeve compatibility. Production status and seller availability are checked separately.

Documented sleeve outcomes

A documented sleeve fit covers the physical combination under its listed conditions. Check electrical requirements separately before purchase.

Replacement options and documented installation requirements
ModelFit statusCoolingElectrical requirementsRequired / conditional partsWhat to check
Friedrich WCVT16B30B2026 WallMaster inverter / R-32, final B suffix (BR_WM_REV 07-15-25)Availability not checkedDocumented fit — conditions applySleeve: Friedrich WSESource 2Source 3Source 416,800 BTU/hSource 1230 VSource 1PlugNEMA 6-15PSource 3ReceptacleNEMA 6-15RSource 3Source 119Specified circuit / fuse15 ASource 3
  • External condensate drain kitPart number: DKOnly if the stated condition appliesSource 4Package: Not documented
4 installation checks
  • Confirm an actual WSE sleeve in serviceable condition. The exact B-suffix model appears in the brochure's installation table, whose note requires a WSE sleeve; dimensions alone are not the evidence for this relation.Source 2
  • Verify the rear grille against the manufacturer installation requirements. Incorrect airflow can recirculate discharge air and cause shutdown; do not assume an old grille is suitable.Source 4
  • Check the actual installation for this 230 V model, NEMA 6-15P plug and manufacturer-specified 15 A circuit/fuse. Cooling running current is a separate specification.Source 1Source 3
  • DK is an optional external drain kit when connection to a condensate disposal system is necessary or desired. It is not a general requirement for every WSE replacement.Source 4

Manufacturer details ↗

Sources