Updated from the reviewed catalog: 23 document a supported new-sleeve installation; 10 need verification of that requirement. Your room, actual supply, sleeve and required parts still need confirmation. This is not a ranking or installation approval.
More checks neededGE
- Nominal supply
- 115 V
- Nominal cooling rating
- 7,800 BTU/h
- Heating
- Cooling only
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 10.6
Inverter documentedWi-Fi documented
Installation: GE RAB26A · required kit included; GE RAB46B · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: GE RAB26A, GE RAB46B. Installation conditions apply.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (5)
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
GE RAB26A
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB26A with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
GE RAB46B
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB46B with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
Evidence for this model and installation
- GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
- GE AJCQ08AXXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AJCQ08AXXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- GE projected Quick Specs — AJCQ08AXXWA, AJCQ12AXXWA ↗Single-page exact-model sheet: drawing, CEER and plug/circuit rows; explicitly marked Projected specifications — subject to change. Not final electrical evidence. · Checked 2026-10-12
2025/2026 inverter generation; exact full SKU covered by 49-5001195
Manufacturer specifications ↗More checks neededGE
- Nominal supply
- 115 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 10.5
Inverter documentedWi-Fi documented
Installation: GE RAB26A · required kit included; GE RAB46B · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: GE RAB26A, GE RAB46B. Installation conditions apply.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (5)
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
GE RAB26A
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB26A with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
GE RAB46B
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB46B with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
Evidence for this model and installation
- GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
- GE AJCQ12AXXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AJCQ12AXXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- GE projected Quick Specs — AJCQ08AXXWA, AJCQ12AXXWA ↗Single-page exact-model sheet: drawing, CEER and plug/circuit rows; explicitly marked Projected specifications — subject to change. Not final electrical evidence. · Checked 2026-10-12
- GE AJCQ12AXXWA — conflicting FEATURES EER ↗Specs & Details > FEATURES > EER: 10.6. CAPACITY > Cooling EER in the same page reports 10.5. These are two section citations, not independent documents. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001195
Manufacturer specifications ↗More checks neededGE
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 10.5
Inverter documentedWi-Fi documented
Installation: GE RAB26A · required kit included; GE RAB46B · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: GE RAB26A, GE RAB46B. Installation conditions apply.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (5)
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
GE RAB26A
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB26A with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
GE RAB46B
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB46B with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
Evidence for this model and installation
- GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
- GE AJCQ12DXXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AJCQ12DXXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- GE projected Quick Specs — AJCQ12DXXWA ↗Single-page exact-model sheet: drawing, CEER and plug/circuit rows; explicitly marked Projected specifications — subject to change. Not final electrical evidence. · Checked 2026-10-12
2025/2026 inverter generation; exact full SKU covered by 49-5001195
Manufacturer specifications ↗More checks neededGE
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Electric heat
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.5
Inverter documentedWi-Fi documented
Installation: GE RAB26A · required kit included; GE RAB46B · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: GE RAB26A, GE RAB46B. Installation conditions apply.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (5)
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
GE RAB26A
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB26A with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
- For heat-capable models, apply all page-16 combustible-material clearances: sides 1 in, front and exterior rear 20 in, above 39-3/8 in, below as the manual’s 4-7/8–6-3/8 in range. Resolve the applicable bottom clearance for the actual installation; do not select an endpoint as a general rule.
GE RAB46B
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB46B with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
- For heat-capable models, apply all page-16 combustible-material clearances: sides 1 in, front and exterior rear 20 in, above 39-3/8 in, below as the manual’s 4-7/8–6-3/8 in range. Resolve the applicable bottom clearance for the actual installation; do not select an endpoint as a general rule.
Evidence for this model and installation
- GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
- GE AJEQ12DCXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AJEQ12DCXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- GE projected Quick Specs — AJEQ12DCXWA ↗Single-page exact-model sheet: drawing, CEER and plug/circuit rows; explicitly marked Projected specifications — subject to change. Not final electrical evidence. · Checked 2026-10-12
2025/2026 inverter generation; exact full SKU covered by 49-5001195
Manufacturer specifications ↗More checks neededGE
- Nominal supply
- 115 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Heat pump with electric backup
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.6
Inverter documentedWi-Fi documented
Installation: GE RAB26A · required kit included; GE RAB46B · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: GE RAB26A, GE RAB46B. Installation conditions apply.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (5)
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
GE RAB26A
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB26A with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
- For heat-capable models, apply all page-16 combustible-material clearances: sides 1 in, front and exterior rear 20 in, above 39-3/8 in, below as the manual’s 4-7/8–6-3/8 in range. Resolve the applicable bottom clearance for the actual installation; do not select an endpoint as a general rule.
GE RAB46B
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB46B with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
- For heat-capable models, apply all page-16 combustible-material clearances: sides 1 in, front and exterior rear 20 in, above 39-3/8 in, below as the manual’s 4-7/8–6-3/8 in range. Resolve the applicable bottom clearance for the actual installation; do not select an endpoint as a general rule.
Evidence for this model and installation
- GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
- GE AJVQ12ACXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AJVQ12ACXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001195
Manufacturer specifications ↗More checks neededGE
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Heat pump with electric backup
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.5
Inverter documentedWi-Fi documented
Installation: GE RAB26A · required kit included; GE RAB46B · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: GE RAB26A, GE RAB46B. Installation conditions apply.
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (5)
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
GE RAB26A
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB26A with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
- For heat-capable models, apply all page-16 combustible-material clearances: sides 1 in, front and exterior rear 20 in, above 39-3/8 in, below as the manual’s 4-7/8–6-3/8 in range. Resolve the applicable bottom clearance for the actual installation; do not select an endpoint as a general rule.
GE RAB46B
Manufacturer sleeve association; listed conditions apply.
Supplied security bracket and screws · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB46B with the RAG13A rear grille. Use the full sleeve/chassis instructions.
- Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
- Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
- Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
- For a new installation the sleeve is purchased separately from the chassis.
- For heat-capable models, apply all page-16 combustible-material clearances: sides 1 in, front and exterior rear 20 in, above 39-3/8 in, below as the manual’s 4-7/8–6-3/8 in range. Resolve the applicable bottom clearance for the actual installation; do not select an endpoint as a general rule.
Evidence for this model and installation
- GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
- GE AJVQ12DCXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AJVQ12DCXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001195
Manufacturer specifications ↗More checks neededGE
- Nominal supply
- 115 V
- Nominal cooling rating
- 7,800 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.6
Inverter documented
Installation: GE RAB24 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: GE RAB24. Installation conditions apply.
Verify circuit ratingWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (5)
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
GE RAB24
Manufacturer sleeve association; listed conditions apply.
Supplied grille, seals, trim, grounding wire and 24-inch security brackets; use applicable parts · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB24 with the supplied stamped aluminum outdoor grille.
- Use the 24-inch sleeve brackets and the applicable sealing, grounding, grille and trim procedures on printed pages 15–24.
- Confirm exact nameplate, grounded outlet and circuit; the sleeve association does not prove electrical suitability.
- RAB24 sleeve is purchased separately; supplied trim/installation hardware is not a wall sleeve.
- Use the applicable sleeve procedure: secure sound housing, required rearward slope, supplied grounding wire with toothed washers, seals and trim; do not leave required hardware unused.
- Use the supplied 24-inch brackets for RAB24 or 26-inch brackets for RAB26A, with flanges behind the sleeve edge; attach both sides as specified on page 24.
Evidence for this model and installation
- GE 24-inch inverter owner and installation manual ↗Cover lists all four exact AK models and INVERTER. Printed/PDF pages 15–19 and 23–24: bare chassis, RAB24/RAB26A, supplied hardware, rearward slope, grounding, GE rear grille, trim and correct 24/26-inch security brackets. RAB26A recommendation spells RAG13 (not RAG13A). No numeric branch-circuit requirement. · Checked 2026-10-13
- GE AKCQ08AXXXA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AKCQ08AXXXA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
- GE AKCQ08AXXXA — conflicting FEATURES EER ↗Specs & Details > FEATURES > EER: 9.6. CAPACITY > Cooling EER in the same page reports 10.6. These are two section citations, not independent documents. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001293
Manufacturer specifications ↗More checks neededGE
- Nominal supply
- 115 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.5
Inverter documented
Installation: GE RAB24 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: GE RAB24. Installation conditions apply.
Verify circuit ratingWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (5)
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
GE RAB24
Manufacturer sleeve association; listed conditions apply.
Supplied grille, seals, trim, grounding wire and 24-inch security brackets; use applicable parts · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB24 with the supplied stamped aluminum outdoor grille.
- Use the 24-inch sleeve brackets and the applicable sealing, grounding, grille and trim procedures on printed pages 15–24.
- Confirm exact nameplate, grounded outlet and circuit; the sleeve association does not prove electrical suitability.
- RAB24 sleeve is purchased separately; supplied trim/installation hardware is not a wall sleeve.
- Use the applicable sleeve procedure: secure sound housing, required rearward slope, supplied grounding wire with toothed washers, seals and trim; do not leave required hardware unused.
- Use the supplied 24-inch brackets for RAB24 or 26-inch brackets for RAB26A, with flanges behind the sleeve edge; attach both sides as specified on page 24.
Evidence for this model and installation
- GE 24-inch inverter owner and installation manual ↗Cover lists all four exact AK models and INVERTER. Printed/PDF pages 15–19 and 23–24: bare chassis, RAB24/RAB26A, supplied hardware, rearward slope, grounding, GE rear grille, trim and correct 24/26-inch security brackets. RAB26A recommendation spells RAG13 (not RAG13A). No numeric branch-circuit requirement. · Checked 2026-10-13
- GE AKCQ12AXXXA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AKCQ12AXXXA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
- GE AKCQ12AXXXA — conflicting FEATURES EER ↗Specs & Details > FEATURES > EER: 9.5. CAPACITY > Cooling EER in the same page reports 10.5. These are two section citations, not independent documents. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001293
Manufacturer specifications ↗More checks neededGE
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 6-15P
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.5
Inverter documented
Installation: GE RAB24 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: GE RAB24. Installation conditions apply.
Verify circuit ratingWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (5)
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
GE RAB24
Manufacturer sleeve association; listed conditions apply.
Supplied grille, seals, trim, grounding wire and 24-inch security brackets; use applicable parts · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB24 with the supplied stamped aluminum outdoor grille.
- Use the 24-inch sleeve brackets and the applicable sealing, grounding, grille and trim procedures on printed pages 15–24.
- Confirm exact nameplate, grounded outlet and circuit; the sleeve association does not prove electrical suitability.
- RAB24 sleeve is purchased separately; supplied trim/installation hardware is not a wall sleeve.
- Use the applicable sleeve procedure: secure sound housing, required rearward slope, supplied grounding wire with toothed washers, seals and trim; do not leave required hardware unused.
- Use the supplied 24-inch brackets for RAB24 or 26-inch brackets for RAB26A, with flanges behind the sleeve edge; attach both sides as specified on page 24.
Evidence for this model and installation
- GE 24-inch inverter owner and installation manual ↗Cover lists all four exact AK models and INVERTER. Printed/PDF pages 15–19 and 23–24: bare chassis, RAB24/RAB26A, supplied hardware, rearward slope, grounding, GE rear grille, trim and correct 24/26-inch security brackets. RAB26A recommendation spells RAG13 (not RAG13A). No numeric branch-circuit requirement. · Checked 2026-10-13
- GE AKCQ12DXXXA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AKCQ12DXXXA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
- GE AKCQ12DXXXA — conflicting FEATURES EER ↗Specs & Details > FEATURES > EER: 9.5. CAPACITY > Cooling EER in the same page reports 10.5. These are two section citations, not independent documents. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001293
Manufacturer specifications ↗More checks neededGE
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Heat pump with electric backup
- Plug
- NEMA 6-20P
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.5
Inverter documentedWi-Fi documented
Installation: GE RAB24 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: GE RAB24. Installation conditions apply.
Verify circuit ratingWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (5)
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
GE RAB24
Manufacturer sleeve association; listed conditions apply.
Supplied grille, seals, trim, grounding wire and 24-inch security brackets; use applicable parts · Required for the listed procedure · Included as reported in source
- The exact-model manual recommends RAB24 with the supplied stamped aluminum outdoor grille.
- Use the 24-inch sleeve brackets and the applicable sealing, grounding, grille and trim procedures on printed pages 15–24.
- Confirm exact nameplate, grounded outlet and circuit; the sleeve association does not prove electrical suitability.
- RAB24 sleeve is purchased separately; supplied trim/installation hardware is not a wall sleeve.
- Use the applicable sleeve procedure: secure sound housing, required rearward slope, supplied grounding wire with toothed washers, seals and trim; do not leave required hardware unused.
- Use the supplied 24-inch brackets for RAB24 or 26-inch brackets for RAB26A, with flanges behind the sleeve edge; attach both sides as specified on page 24.
Evidence for this model and installation
- GE 24-inch inverter owner and installation manual ↗Cover lists all four exact AK models and INVERTER. Printed/PDF pages 15–19 and 23–24: bare chassis, RAB24/RAB26A, supplied hardware, rearward slope, grounding, GE rear grille, trim and correct 24/26-inch security brackets. RAB26A recommendation spells RAG13 (not RAG13A). No numeric branch-circuit requirement. · Checked 2026-10-13
- GE AKVQ12DXXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AKVQ12DXXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001293
Manufacturer specifications ↗More checks neededLG
- Nominal supply
- 115 V
- Nominal cooling rating
- 9,800 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.6
Installation: LG AXSVA1 · required kit included; LG AXSVA4 · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
Reported indoor noise: 56 dBA (Manufacturer rating; fan speed and test conditions not stated). Test conditions vary by source.
What matches (1)
- Documented sleeve option: LG AXSVA1, LG AXSVA4. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
LG AXSVA1
Manufacturer sleeve association; listed conditions apply.
Supplied installation parts: grille, applicable insulation, shims and trim; sleeve sold separately · Required for the listed procedure · Included as reported in source
- The current exact-UPC manufacturer sheet lists this sleeve as a separately sold optional accessory. Check the exact housing and model nameplate.
- Follow LGE sleeve Procedure A, including serviceable rear flange/grille, specified rearward slope, applicable supplied seals/shims and trim; sleeve is secured to the wall.
- 115 V model: use the documented 15 A circuit and matching grounded 5-15 plug/receptacle. Do not assume the existing outlet or circuit from the old unit.
LG AXSVA4
Manufacturer sleeve association; listed conditions apply.
Supplied installation parts: grille, applicable insulation, shims and trim; sleeve sold separately · Required for the listed procedure · Included as reported in source
- The current exact-UPC manufacturer sheet lists this sleeve as a separately sold optional accessory. Check the exact housing and model nameplate.
- Follow LGE sleeve Procedure A, including serviceable rear flange/grille, specified rearward slope, applicable supplied seals/shims and trim; sleeve is secured to the wall.
- 115 V model: use the documented 15 A circuit and matching grounded 5-15 plug/receptacle. Do not assume the existing outlet or circuit from the old unit.
Evidence for this model and installation
- LG US wall air conditioner category ↗Eleven LT equipment entries observed in initial category HTML; accessories excluded. Dynamic pagination is not proof of complete coverage. · Checked 2026-10-12
- LG owner manual — cool ↗Support associations checked 2026-10-12; visually reviewed 2026-10-13. Printed/PDF page 9 explicitly lists LT0816CER, LT1016CER, LT12124CNR (115 V) and LT1036CER, LT1236CER, LT1430CNR (230 V), 15 A circuit and outlet drawings; pages 11–13 packing list and LGE sleeve Procedure A. LT1216CER has a separate exact support manual. · Checked 2026-10-13
- LG LT1016CER — current product specifications ↗Specifications > Electrical Ratings, Performance, Features and Dimensions/Weight; public page specification data; product modelStatus ACTIVE checked separately from stock. · Checked 2026-10-13
- LG LT1016CER — exact support/document association ↗Selected support sales suffix and Download Manuals list; suffix is not automatically an alias of another physical generation. · Checked 2026-10-12
- LG LT1016CER — linked specification sheet ↗Exact SKU specifications, refrigerant and Optional Accessories. Dates differ across PDFs; older electrical/performance tables are not merged into current page values. · Checked 2026-10-12
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
Reviewed marketed SKU and UPC 048231379618; selected support LT1016CER.AT1AUSL. Base model is not an alias of every historical sales suffix.
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 115 V
- Nominal cooling rating
- 8,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.1
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT08B10A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Sleeve decision needs review.
Sources disagree on a fit-critical fact. This option cannot be a confirmed fit.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 115 V
- Nominal cooling rating
- 10,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.1
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT10B10A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Sleeve decision needs review.
Sources disagree on a fit-critical fact. This option cannot be a confirmed fit.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 230 V
- Nominal cooling rating
- 10,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 6-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.1
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT10B30A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Sleeve decision needs review.
Sources disagree on a fit-critical fact. This option cannot be a confirmed fit.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 115 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT12B10A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Sleeve decision needs review.
Sources disagree on a fit-critical fact. This option cannot be a confirmed fit.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 6-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT12B30A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Sleeve decision needs review.
Sources disagree on a fit-critical fact. This option cannot be a confirmed fit.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 230 V
- Nominal cooling rating
- 14,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 6-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 9.3
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT14B30A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Sleeve decision needs review.
Sources disagree on a fit-critical fact. This option cannot be a confirmed fit.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 115 V
- Nominal cooling rating
- 8,000 BTU/h
- Heating
- Electric heat
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 9.6
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UET08B11A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Sleeve decision needs review.
Sources disagree on a fit-critical fact. This option cannot be a confirmed fit.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 230 V
- Nominal cooling rating
- 10,000 BTU/h
- Heating
- Electric heat
- Plug
- NEMA 6-20P
- Specified circuit / fuse
- 20 A
- CEER (nominal rating)
- 9.6
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UET10B33A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Sleeve decision needs review.
Sources disagree on a fit-critical fact. This option cannot be a confirmed fit.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Electric heat
- Plug
- NEMA 6-20P
- Specified circuit / fuse
- 20 A
- CEER (nominal rating)
- 9.6
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UET12B33A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Sleeve decision needs review.
Sources disagree on a fit-critical fact. This option cannot be a confirmed fit.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 230 V
- Nominal cooling rating
- 14,000 BTU/h
- Heating
- Electric heat
- Plug
- NEMA 6-20P
- Specified circuit / fuse
- 20 A
- CEER (nominal rating)
- 9.3
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UET14B33A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Friedrich USEZ
Sleeve decision needs review.
Sources disagree on a fit-critical fact. This option cannot be a confirmed fit.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 115 V
- Nominal cooling rating
- 13,500 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 13.2
Inverter documentedWi-Fi documented
Installation: Friedrich WSE · follow listed conditions
What matches (1)
- Documented sleeve option: Friedrich WSE. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
Friedrich WSE
Manufacturer sleeve association; listed conditions apply.
External condensate drain kit (DK) · Optional or conditional · Package inclusion not established
- Confirm an actual WSE sleeve in serviceable condition. The exact B-suffix model appears in the brochure's installation table, whose note requires a WSE sleeve; dimensions alone are not the evidence for this relation.
- Verify the rear grille against the manufacturer installation requirements. Incorrect airflow can recirculate discharge air and cause shutdown; do not assume an old grille is suitable.
- Check the actual installation for this 115 V model, NEMA 5-15P plug and manufacturer-specified 15 A circuit/fuse. Cooling running current is a separate specification.
- DK is an optional external drain kit when connection to a condensate disposal system is necessary or desired. It is not a general requirement for every WSE replacement.
Evidence for this model and installation
2026 WallMaster inverter / R-32, final B suffix (BR_WM_REV 07-15-25)
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 230 V
- Nominal cooling rating
- 16,800 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 6-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 12.6
Inverter documentedWi-Fi documented
Installation: Friedrich WSE · follow listed conditions
What matches (1)
- Documented sleeve option: Friedrich WSE. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
Friedrich WSE
Manufacturer sleeve association; listed conditions apply.
External condensate drain kit (DK) · Optional or conditional · Package inclusion not established
- Confirm an actual WSE sleeve in serviceable condition. The exact B-suffix model appears in the brochure's installation table, whose note requires a WSE sleeve; dimensions alone are not the evidence for this relation.
- Verify the rear grille against the manufacturer installation requirements. Incorrect airflow can recirculate discharge air and cause shutdown; do not assume an old grille is suitable.
- Check the actual installation for this 230 V model, NEMA 6-15P plug and manufacturer-specified 15 A circuit/fuse. Cooling running current is a separate specification.
- DK is an optional external drain kit when connection to a condensate disposal system is necessary or desired. It is not a general requirement for every WSE replacement.
Evidence for this model and installation
2026 WallMaster inverter / R-32, final B suffix (BR_WM_REV 07-15-25)
Manufacturer specifications ↗