115-volt through-the-wall air conditioners for a new installation

Selected: A new installation · 115 V supply

Compare 115 V operation, heating options and installation evidence for a new wall sleeve. Confirm the exact receptacle and circuit rating before purchase.

19 models still in consideration0 meet documented filters · 19 need checksSee models ↓

19 models still in consideration

The shortlist updates with each answer. Confirm room capacity, electrical supply and installation conditions before purchase. Seller stock and prices have not been checked.

Refine by room, outlet and features
Circuit breaker / fuse
Sun, occupants and other sizing adjustments

Cooling estimate: needs a sizing check · ENERGY STAR chart ↗

Voltage, outlet configuration and circuit protection are separate checks. Missing or disputed feature data stays unconfirmed; indoor noise data is not a “quietest” ranking.

Catalog coverage (44 profiles)

More checks needed (19)

Unknown or disputed facts remain visible in each profile. These are candidates for verification, not installation approvals.

More checks neededGE

AJCQ08AXXWA

Sleeve: GE RAB26A, GE RAB46B documented

Power: 115 V operation documented

Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.

Nominal supply
115 V
Cooling at 115 V
7,800 BTU/h
Heating
Cooling only
Plug
Not established
Specified circuit / fuse
Not established
CEER at 115 V
10.6
Inverter documentedWi-Fi documented

Installation: GE RAB26A · required kit included; GE RAB46B · required kit included

Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.

What matches (2)
  • Documented sleeve option: GE RAB26A, GE RAB46B. Installation conditions apply.
  • 115 V operation is documented.
Verify circuit rating, plug, outlet
Why these facts need checking
  • Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
  • Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
  • Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (4)
  • The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
  • Exact plug/receptacle configuration needs confirmation.
  • Room estimate or model capacity at the selected voltage needs checking.
  • Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.

Seller availability unverified for this exact model.

Sleeves, required parts and sources

GE RAB26A

Manufacturer sleeve association; listed conditions apply.

Supplied security bracket and screws · Required for the listed procedure · Included as reported in source

  • The exact-model manual recommends RAB26A with the RAG13A rear grille. Use the full sleeve/chassis instructions.
  • Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
  • Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
  • Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
  • For a new installation the sleeve is purchased separately from the chassis.

GE RAB46B

Manufacturer sleeve association; listed conditions apply.

Supplied security bracket and screws · Required for the listed procedure · Included as reported in source

  • The exact-model manual recommends RAB46B with the RAG13A rear grille. Use the full sleeve/chassis instructions.
  • Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
  • Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
  • Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
  • For a new installation the sleeve is purchased separately from the chassis.

Evidence for this model and installation

  • GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
  • GE AJCQ08AXXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
  • GE AJCQ08AXXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
  • GE projected Quick Specs — AJCQ08AXXWA, AJCQ12AXXWA ↗Single-page exact-model sheet: drawing, CEER and plug/circuit rows; explicitly marked Projected specifications — subject to change. Not final electrical evidence. · Checked 2026-10-12

2025/2026 inverter generation; exact full SKU covered by 49-5001195

Manufacturer specifications ↗
More checks neededGE

AJCQ12AXXWA

Sleeve: GE RAB26A, GE RAB46B documented

Power: 115 V operation documented

Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.

Nominal supply
115 V
Cooling at 115 V
12,000 BTU/h
Heating
Cooling only
Plug
Not established
Specified circuit / fuse
Not established
CEER at 115 V
10.5
Inverter documentedWi-Fi documented

Installation: GE RAB26A · required kit included; GE RAB46B · required kit included

Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.

What matches (2)
  • Documented sleeve option: GE RAB26A, GE RAB46B. Installation conditions apply.
  • 115 V operation is documented.
Verify circuit rating, plug, outlet
Why these facts need checking
  • Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
  • Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
  • Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (4)
  • The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
  • Exact plug/receptacle configuration needs confirmation.
  • Room estimate or model capacity at the selected voltage needs checking.
  • Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.

Seller availability unverified for this exact model.

Sleeves, required parts and sources

GE RAB26A

Manufacturer sleeve association; listed conditions apply.

Supplied security bracket and screws · Required for the listed procedure · Included as reported in source

  • The exact-model manual recommends RAB26A with the RAG13A rear grille. Use the full sleeve/chassis instructions.
  • Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
  • Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
  • Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
  • For a new installation the sleeve is purchased separately from the chassis.

GE RAB46B

Manufacturer sleeve association; listed conditions apply.

Supplied security bracket and screws · Required for the listed procedure · Included as reported in source

  • The exact-model manual recommends RAB46B with the RAG13A rear grille. Use the full sleeve/chassis instructions.
  • Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
  • Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
  • Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
  • For a new installation the sleeve is purchased separately from the chassis.

Evidence for this model and installation

  • GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
  • GE AJCQ12AXXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
  • GE AJCQ12AXXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
  • GE projected Quick Specs — AJCQ08AXXWA, AJCQ12AXXWA ↗Single-page exact-model sheet: drawing, CEER and plug/circuit rows; explicitly marked Projected specifications — subject to change. Not final electrical evidence. · Checked 2026-10-12
  • GE AJCQ12AXXWA — conflicting FEATURES EER ↗Specs & Details > FEATURES > EER: 10.6. CAPACITY > Cooling EER in the same page reports 10.5. These are two section citations, not independent documents. · Checked 2026-10-13

2025/2026 inverter generation; exact full SKU covered by 49-5001195

Manufacturer specifications ↗
More checks neededGE

AJVQ12ACXWA

Sleeve: GE RAB26A, GE RAB46B documented

Power: 115 V operation documented

Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.

Nominal supply
115 V
Cooling at 115 V
12,000 BTU/h
Heating
Heat pump with electric backup
Plug
Not established
Specified circuit / fuse
Not established
CEER at 115 V
9.6
Inverter documentedWi-Fi documented

Installation: GE RAB26A · required kit included; GE RAB46B · required kit included

Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.

What matches (2)
  • Documented sleeve option: GE RAB26A, GE RAB46B. Installation conditions apply.
  • 115 V operation is documented.
Verify circuit rating, plug, outlet
Why these facts need checking
  • Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
  • Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
  • Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (4)
  • The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
  • Exact plug/receptacle configuration needs confirmation.
  • Room estimate or model capacity at the selected voltage needs checking.
  • Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.

Seller availability unverified for this exact model.

Sleeves, required parts and sources

GE RAB26A

Manufacturer sleeve association; listed conditions apply.

Supplied security bracket and screws · Required for the listed procedure · Included as reported in source

  • The exact-model manual recommends RAB26A with the RAG13A rear grille. Use the full sleeve/chassis instructions.
  • Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
  • Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
  • Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
  • For a new installation the sleeve is purchased separately from the chassis.
  • For heat-capable models, apply all page-16 combustible-material clearances: sides 1 in, front and exterior rear 20 in, above 39-3/8 in, below as the manual’s 4-7/8–6-3/8 in range. Resolve the applicable bottom clearance for the actual installation; do not select an endpoint as a general rule.

GE RAB46B

Manufacturer sleeve association; listed conditions apply.

Supplied security bracket and screws · Required for the listed procedure · Included as reported in source

  • The exact-model manual recommends RAB46B with the RAG13A rear grille. Use the full sleeve/chassis instructions.
  • Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
  • Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
  • Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
  • For a new installation the sleeve is purchased separately from the chassis.
  • For heat-capable models, apply all page-16 combustible-material clearances: sides 1 in, front and exterior rear 20 in, above 39-3/8 in, below as the manual’s 4-7/8–6-3/8 in range. Resolve the applicable bottom clearance for the actual installation; do not select an endpoint as a general rule.

Evidence for this model and installation

  • GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
  • GE AJVQ12ACXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
  • GE AJVQ12ACXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13

2025/2026 inverter generation; exact full SKU covered by 49-5001195

Manufacturer specifications ↗
More checks neededGE

AKCQ08AXXXA

Sleeve: GE RAB24 documented

Power: 115 V operation documented

Next check: GE lists 15 A in preliminary specifications. Confirm the circuit rating for the exact production unit before purchase.

Nominal supply
115 V
Cooling at 115 V
7,800 BTU/h
Heating
Cooling only
Plug
NEMA 5-15P
Specified circuit / fuse
Not established
CEER at 115 V
9.6
Inverter documented

Installation: GE RAB24 · required kit included

Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.

What matches (2)
  • Documented sleeve option: GE RAB24. Installation conditions apply.
  • 115 V operation is documented.
Verify circuit rating
Why these facts need checking
  • GE lists 15 A in preliminary specifications. Confirm the circuit rating for the exact production unit before purchase.
Checks before purchase (4)
  • GE lists 15 A in preliminary specifications. Confirm the circuit rating for the exact production unit before purchase.
  • Exact plug/receptacle configuration needs confirmation.
  • Room estimate or model capacity at the selected voltage needs checking.
  • Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.

Seller availability unverified for this exact model.

Sleeves, required parts and sources

GE RAB24

Manufacturer sleeve association; listed conditions apply.

Supplied grille, seals, trim, grounding wire and 24-inch security brackets; use applicable parts · Required for the listed procedure · Included as reported in source

  • The exact-model manual recommends RAB24 with the supplied stamped aluminum outdoor grille.
  • Use the 24-inch sleeve brackets and the applicable sealing, grounding, grille and trim procedures on printed pages 15–24.
  • Confirm exact nameplate, grounded outlet and circuit; the sleeve association does not prove electrical suitability.
  • RAB24 sleeve is purchased separately; supplied trim/installation hardware is not a wall sleeve.
  • Use the applicable sleeve procedure: secure sound housing, required rearward slope, supplied grounding wire with toothed washers, seals and trim; do not leave required hardware unused.
  • Use the supplied 24-inch brackets for RAB24 or 26-inch brackets for RAB26A, with flanges behind the sleeve edge; attach both sides as specified on page 24.

Evidence for this model and installation

  • GE 24-inch inverter owner and installation manual ↗Cover lists all four exact AK models and INVERTER. Printed/PDF pages 15–19 and 23–24: bare chassis, RAB24/RAB26A, supplied hardware, rearward slope, grounding, GE rear grille, trim and correct 24/26-inch security brackets. RAB26A recommendation spells RAG13 (not RAG13A). No numeric branch-circuit requirement. Printed pages 16 and 18 list the 27 × 16-3/4 × 16-3/4 in Friedrich housing and its existing-sleeve adaptation with the supplied rear louver, blocks, seals and grounding. · Checked 2026-11-22
  • GE AKCQ08AXXXA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
  • GE AKCQ08AXXXA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
  • NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
  • GE AKCQ08AXXXA — conflicting FEATURES EER ↗Specs & Details > FEATURES > EER: 9.6. CAPACITY > Cooling EER in the same page reports 10.6. These are two section citations, not independent documents. · Checked 2026-10-13
  • GE 2026 Universal Fit 24-inch AC brochure, preliminary circuit size ↗PDF page 8, printed spread pages 14–15, right-hand Cool-Only table. The AKCQ08AXXXA and AKCQ12AXXXA columns show 15 A in Circuit Size Amps. Both pages mark the values projected and subject to change. · Checked 2026-11-22

2025/2026 inverter generation; exact full SKU covered by 49-5001293

Manufacturer specifications ↗
More checks neededGE

AKCQ12AXXXA

Sleeve: GE RAB24 documented

Power: 115 V operation documented

Next check: GE lists 15 A in preliminary specifications. Confirm the circuit rating for the exact production unit before purchase.

Nominal supply
115 V
Cooling at 115 V
12,000 BTU/h
Heating
Cooling only
Plug
NEMA 5-15P
Specified circuit / fuse
Not established
CEER at 115 V
9.5
Inverter documented

Installation: GE RAB24 · required kit included

Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.

What matches (2)
  • Documented sleeve option: GE RAB24. Installation conditions apply.
  • 115 V operation is documented.
Verify circuit rating
Why these facts need checking
  • GE lists 15 A in preliminary specifications. Confirm the circuit rating for the exact production unit before purchase.
Checks before purchase (4)
  • GE lists 15 A in preliminary specifications. Confirm the circuit rating for the exact production unit before purchase.
  • Exact plug/receptacle configuration needs confirmation.
  • Room estimate or model capacity at the selected voltage needs checking.
  • Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.

Seller availability unverified for this exact model.

Sleeves, required parts and sources

GE RAB24

Manufacturer sleeve association; listed conditions apply.

Supplied grille, seals, trim, grounding wire and 24-inch security brackets; use applicable parts · Required for the listed procedure · Included as reported in source

  • The exact-model manual recommends RAB24 with the supplied stamped aluminum outdoor grille.
  • Use the 24-inch sleeve brackets and the applicable sealing, grounding, grille and trim procedures on printed pages 15–24.
  • Confirm exact nameplate, grounded outlet and circuit; the sleeve association does not prove electrical suitability.
  • RAB24 sleeve is purchased separately; supplied trim/installation hardware is not a wall sleeve.
  • Use the applicable sleeve procedure: secure sound housing, required rearward slope, supplied grounding wire with toothed washers, seals and trim; do not leave required hardware unused.
  • Use the supplied 24-inch brackets for RAB24 or 26-inch brackets for RAB26A, with flanges behind the sleeve edge; attach both sides as specified on page 24.

Evidence for this model and installation

  • GE 24-inch inverter owner and installation manual ↗Cover lists all four exact AK models and INVERTER. Printed/PDF pages 15–19 and 23–24: bare chassis, RAB24/RAB26A, supplied hardware, rearward slope, grounding, GE rear grille, trim and correct 24/26-inch security brackets. RAB26A recommendation spells RAG13 (not RAG13A). No numeric branch-circuit requirement. Printed pages 16 and 18 list the 27 × 16-3/4 × 16-3/4 in Friedrich housing and its existing-sleeve adaptation with the supplied rear louver, blocks, seals and grounding. · Checked 2026-11-22
  • GE AKCQ12AXXXA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
  • GE AKCQ12AXXXA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
  • NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
  • GE AKCQ12AXXXA — conflicting FEATURES EER ↗Specs & Details > FEATURES > EER: 9.5. CAPACITY > Cooling EER in the same page reports 10.5. These are two section citations, not independent documents. · Checked 2026-10-13
  • GE 2026 Universal Fit 24-inch AC brochure, preliminary circuit size ↗PDF page 8, printed spread pages 14–15, right-hand Cool-Only table. The AKCQ08AXXXA and AKCQ12AXXXA columns show 15 A in Circuit Size Amps. Both pages mark the values projected and subject to change. · Checked 2026-11-22

2025/2026 inverter generation; exact full SKU covered by 49-5001293

Manufacturer specifications ↗
More checks neededFrigidaire

FHTC103WB1

Sleeve: Frigidaire 912001373 documented

Power: 115 V operation documented

Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.

Nominal supply
115 V
Cooling at 115 V
10,000 BTU/h
Heating
Cooling only
Plug
Not established
Specified circuit / fuse
Not established
CEER at 115 V
9.6

Installation: Frigidaire 912001373 · required kit included

Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.

What matches (2)
  • Documented sleeve option: Frigidaire 912001373. Installation conditions apply.
  • 115 V operation is documented.
Verify circuit rating, plug, outlet
Why these facts need checking
  • Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
  • Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
  • Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
Checks before purchase (5)
  • Current production status needs confirmation.
  • The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.
  • Exact plug/receptacle configuration needs confirmation.
  • Room estimate or model capacity at the selected voltage needs checking.
  • Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.

Seller availability unverified for this exact model.

Sleeves, required parts and sources

Frigidaire 912001373

Manufacturer sleeve association; listed conditions apply.

Supplied rear grille and trim · Required for the listed procedure · Included as reported in source

Wall sleeve for a new installation (912001373) · Optional or conditional · Purchased separately

  • The exact Frigidaire product sheet names 912001373 as the separately sold wall sleeve.
  • Follow the model installation guide for the supplied rear grille, trim and any required seals or grounding.
  • Confirm the rough opening for the actual sleeve at the site before cutting the wall. The AC sheet’s sleeve dimensions do not specify that rough opening.

Evidence for this model and installation

Frigidaire R-32 built-in wall AC / specification edition 02/25

Manufacturer specifications ↗
More checks neededFrigidaire

FHTC123WB1

Sleeve: Frigidaire 912001373 documented

Power: 115 V operation documented

Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.

Nominal supply
115 V
Cooling at 115 V
12,000 BTU/h
Heating
Cooling only
Plug
Not established
Specified circuit / fuse
Not established
CEER at 115 V
9.5

Installation: Frigidaire 912001373 · required kit included

Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.

What matches (2)
  • Documented sleeve option: Frigidaire 912001373. Installation conditions apply.
  • 115 V operation is documented.
Verify circuit rating, plug, outlet
Why these facts need checking
  • Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
  • Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
  • Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
Checks before purchase (5)
  • Current production status needs confirmation.
  • The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.
  • Exact plug/receptacle configuration needs confirmation.
  • Room estimate or model capacity at the selected voltage needs checking.
  • Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources

Frigidaire 912001373

Manufacturer sleeve association; listed conditions apply.

Supplied rear grille and trim · Required for the listed procedure · Included as reported in source

Wall sleeve for a new installation (912001373) · Optional or conditional · Purchased separately

  • The exact Frigidaire product sheet names 912001373 as the separately sold wall sleeve.
  • Follow the model installation guide for the supplied rear grille, trim and any required seals or grounding.
  • Confirm the rough opening for the actual sleeve at the site before cutting the wall. The AC sheet’s sleeve dimensions do not specify that rough opening.

Evidence for this model and installation

Frigidaire R-32 built-in wall AC / specification edition 02/25

Manufacturer specifications ↗
More checks neededFrigidaire

FHTE083WA1

Sleeve: Frigidaire 912001373 documented

Power: 115 V operation documented

Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.

Nominal supply
115 V
Cooling at 115 V
8,000 BTU/h
Heating
Electric heat
Plug
Not established
Specified circuit / fuse
Not established
CEER at 115 V
9.6

Installation: Frigidaire 912001373 · required kit included

Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.

What matches (2)
  • Documented sleeve option: Frigidaire 912001373. Installation conditions apply.
  • 115 V operation is documented.
Verify circuit rating, plug, outlet
Why these facts need checking
  • Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
  • Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
  • Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase.
Checks before purchase (5)
  • Current production status needs confirmation.
  • The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Frigidaire to confirm it before purchase; your circuit answer cannot fill this gap.
  • Exact plug/receptacle configuration needs confirmation.
  • Room estimate or model capacity at the selected voltage needs checking.
  • Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.

Seller availability unverified for this exact model.

Sleeves, required parts and sources

Frigidaire 912001373

Manufacturer sleeve association; listed conditions apply.

Supplied rear grille and trim · Required for the listed procedure · Included as reported in source

Wall sleeve for a new installation (912001373) · Optional or conditional · Purchased separately

  • The exact Frigidaire product sheet names 912001373 as the separately sold wall sleeve.
  • Follow the model installation guide for the supplied rear grille, trim and any required seals or grounding.
  • Confirm the rough opening for the actual sleeve at the site before cutting the wall. The AC sheet’s sleeve dimensions do not specify that rough opening.

Evidence for this model and installation

Frigidaire R-32 built-in wall AC / specification edition 11/24

Manufacturer specifications ↗
More checks neededKeystone

KSTAT08-1D

Sleeve: Keystone KSTSLV1 documented

Power: 115 V operation documented

Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Keystone to confirm it before purchase; your circuit answer cannot fill this gap.

Nominal supply
115 V
Cooling at 115 V
8,000 BTU/h
Heating
Cooling only
Plug
NEMA 5-15P
Specified circuit / fuse
Not established
CEER at 115 V
Not established

Installation: Keystone KSTSLV1 · required kit included

Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.

What matches (2)
  • Documented sleeve option: Keystone KSTSLV1. Installation conditions apply.
  • 115 V operation is documented.
Verify circuit rating
Why these facts need checking
  • Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask Keystone to confirm it before purchase.
Checks before purchase (5)
  • Current production status needs confirmation.
  • The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Keystone to confirm it before purchase; your circuit answer cannot fill this gap.
  • Exact plug/receptacle configuration needs confirmation.
  • Room estimate or model capacity at the selected voltage needs checking.
  • Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.

Seller availability unverified for this exact model.

Sleeves, required parts and sources

Keystone KSTSLV1

Manufacturer sleeve association; listed conditions apply.

Supplied rear grille and interior trim · Required for the listed procedure · Included as reported in source

Wall sleeve for a new installation (KSTSLV1) · Optional or conditional · Purchased separately

  • The exact AC product page lists KSTSLV1 as the new sleeve, sold separately.
  • Use the rear grille supplied with the AC and the applicable trim. Verify the rough opening with the installation instructions before cutting.
  • Use the dedicated circuit described in the owner guide and confirm the production-unit circuit rating.

Evidence for this model and installation

Keystone D-series through-the-wall room AC

Manufacturer specifications ↗
More checks neededKeystone

KSTAT12-1D

Sleeve: Keystone KSTSLV1 documented

Power: 115 V operation documented

Next check: The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Keystone to confirm it before purchase; your circuit answer cannot fill this gap.

Nominal supply
115 V
Cooling at 115 V
12,000 BTU/h
Heating
Cooling only
Plug
NEMA 5-15P
Specified circuit / fuse
Not established
CEER at 115 V
Not established

Installation: Keystone KSTSLV1 · required kit included

Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.

What matches (2)
  • Documented sleeve option: Keystone KSTSLV1. Installation conditions apply.
  • 115 V operation is documented.
Verify circuit rating
Why these facts need checking
  • Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask Keystone to confirm it before purchase.
Checks before purchase (5)
  • Current production status needs confirmation.
  • The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask Keystone to confirm it before purchase; your circuit answer cannot fill this gap.
  • Exact plug/receptacle configuration needs confirmation.
  • Room estimate or model capacity at the selected voltage needs checking.
  • Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.

Seller availability unverified for this exact model.

Sleeves, required parts and sources

Keystone KSTSLV1

Manufacturer sleeve association; listed conditions apply.

Supplied rear grille and interior trim · Required for the listed procedure · Included as reported in source

Wall sleeve for a new installation (KSTSLV1) · Optional or conditional · Purchased separately

  • The exact AC product page lists KSTSLV1 as the new sleeve, sold separately.
  • Use the rear grille supplied with the AC and the applicable trim. Verify the rough opening with the installation instructions before cutting.
  • Use the dedicated circuit described in the owner guide and confirm the production-unit circuit rating.

Evidence for this model and installation

Keystone D-series through-the-wall room AC

Manufacturer specifications ↗
More checks neededLG

LT0816CER

Power: 115 V operation documented

Next check: No positive manufacturer sleeve decision is available under these answers.

Nominal supply
115 V
Cooling at 115 V
8,000 BTU/h
Heating
Cooling only
Plug
NEMA 5-15P
Specified circuit / fuse
15 A
CEER at 115 V
10.6

Reported indoor noise: 56 dBA (Manufacturer rating; fan speed and test conditions not stated). Test conditions vary by source.

What matches (1)
  • 115 V operation is documented.
Checks before purchase (5)
  • No positive manufacturer sleeve decision is available under these answers.
  • Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
  • Exact plug/receptacle configuration needs confirmation.
  • Room estimate or model capacity at the selected voltage needs checking.
  • Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.

Seller availability unverified for this exact model.

Sleeves, required parts and sources

LG AXSVA1

Sleeve decision needs review.

Provided installation hardware; apply exact sleeve procedure · Required for the listed procedure · Included as reported in source

  • The current exact-model sheet does not name AXSVA1/AXSVA4. The associated manual describes an LGE sleeve and Procedure A. This generic description and matching dimensions do not establish this exact part/model relation.
  • The model-associated manual supplies grille/insulation/shims/trim and describes LGE Procedure A. Follow the exact sleeve procedure and rearward slope; this is not independent evidence identifying this sleeve SKU.

LG AXSVA4

Sleeve decision needs review.

Provided installation hardware; apply exact sleeve procedure · Required for the listed procedure · Included as reported in source

  • The current exact-model sheet does not name AXSVA1/AXSVA4. The associated manual describes an LGE sleeve and Procedure A. This generic description and matching dimensions do not establish this exact part/model relation.
  • The model-associated manual supplies grille/insulation/shims/trim and describes LGE Procedure A. Follow the exact sleeve procedure and rearward slope; this is not independent evidence identifying this sleeve SKU.

Evidence for this model and installation

  • LG US wall air conditioner category ↗Eleven LT equipment entries observed in initial category HTML; accessories excluded. Dynamic pagination is not proof of complete coverage. · Checked 2026-10-12
  • LG owner manual — cool ↗Support associations checked 2026-10-12; visually reviewed 2026-10-13. Printed/PDF page 9 explicitly lists LT0816CER, LT1016CER, LT12124CNR (115 V) and LT1036CER, LT1236CER, LT1430CNR (230 V), 15 A circuit and outlet drawings; pages 11–13 packing list and LGE sleeve Procedure A. LT1216CER has a separate exact support manual. Printed pages 12 and 15–16 cover the 27 × 16-3/4 × 16-3/4 in Friedrich housing under existing-sleeve Procedure C. · Checked 2026-11-22
  • LG LT0816CER — current product specifications ↗Specifications > Electrical Ratings, Performance, Features and Dimensions/Weight; public page specification data; product modelStatus ACTIVE checked separately from stock. · Checked 2026-10-13
  • LG LT0816CER — exact support/document association ↗Selected support sales suffix and Download Manuals list; suffix is not automatically an alias of another physical generation. · Checked 2026-10-12
  • LG LT0816CER — linked specification sheet ↗Exact SKU specifications, refrigerant and Optional Accessories. Dates differ across PDFs; older electrical/performance tables are not merged into current page values. · Checked 2026-10-12
  • NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13

Reviewed marketed SKU and UPC 048231379601; selected support LT0816CER.AT1AUSB. Base model is not an alias of every historical sales suffix.

Manufacturer specifications ↗
More checks neededLG

LT1016CER

Sleeve: LG AXSVA1, LG AXSVA4 documented

Power: 115 V operation documented

Next check: Compare the actual circuit with the exact manufacturer circuit/fuse requirement.

Nominal supply
115 V
Cooling at 115 V
9,800 BTU/h
Heating
Cooling only
Plug
NEMA 5-15P
Specified circuit / fuse
15 A
CEER at 115 V
10.6

Installation: LG AXSVA1 · required kit included; LG AXSVA4 · required kit included

Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.

Reported indoor noise: 56 dBA (Manufacturer rating; fan speed and test conditions not stated). Test conditions vary by source.

What matches (2)
  • Documented sleeve option: LG AXSVA1, LG AXSVA4. Installation conditions apply.
  • 115 V operation is documented.
Checks before purchase (4)
  • Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
  • Exact plug/receptacle configuration needs confirmation.
  • Room estimate or model capacity at the selected voltage needs checking.
  • Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.

Seller availability unverified for this exact model.

Sleeves, required parts and sources

LG AXSVA1

Manufacturer sleeve association; listed conditions apply.

Supplied installation parts: grille, applicable insulation, shims and trim; sleeve sold separately · Required for the listed procedure · Included as reported in source

  • The current exact-UPC manufacturer sheet lists this sleeve as a separately sold optional accessory. Check the exact housing and model nameplate.
  • Follow LGE sleeve Procedure A, including serviceable rear flange/grille, specified rearward slope, applicable supplied seals/shims and trim; sleeve is secured to the wall.
  • 115 V model: use the documented 15 A circuit and matching grounded 5-15 plug/receptacle. Do not assume the existing outlet or circuit from the old unit.

LG AXSVA4

Manufacturer sleeve association; listed conditions apply.

Supplied installation parts: grille, applicable insulation, shims and trim; sleeve sold separately · Required for the listed procedure · Included as reported in source

  • The current exact-UPC manufacturer sheet lists this sleeve as a separately sold optional accessory. Check the exact housing and model nameplate.
  • Follow LGE sleeve Procedure A, including serviceable rear flange/grille, specified rearward slope, applicable supplied seals/shims and trim; sleeve is secured to the wall.
  • 115 V model: use the documented 15 A circuit and matching grounded 5-15 plug/receptacle. Do not assume the existing outlet or circuit from the old unit.

Evidence for this model and installation

  • LG US wall air conditioner category ↗Eleven LT equipment entries observed in initial category HTML; accessories excluded. Dynamic pagination is not proof of complete coverage. · Checked 2026-10-12
  • LG owner manual — cool ↗Support associations checked 2026-10-12; visually reviewed 2026-10-13. Printed/PDF page 9 explicitly lists LT0816CER, LT1016CER, LT12124CNR (115 V) and LT1036CER, LT1236CER, LT1430CNR (230 V), 15 A circuit and outlet drawings; pages 11–13 packing list and LGE sleeve Procedure A. LT1216CER has a separate exact support manual. Printed pages 12 and 15–16 cover the 27 × 16-3/4 × 16-3/4 in Friedrich housing under existing-sleeve Procedure C. · Checked 2026-11-22
  • LG LT1016CER — current product specifications ↗Specifications > Electrical Ratings, Performance, Features and Dimensions/Weight; public page specification data; product modelStatus ACTIVE checked separately from stock. · Checked 2026-10-13
  • LG LT1016CER — exact support/document association ↗Selected support sales suffix and Download Manuals list; suffix is not automatically an alias of another physical generation. · Checked 2026-10-12
  • LG LT1016CER — linked specification sheet ↗Exact SKU specifications, refrigerant and Optional Accessories. Dates differ across PDFs; older electrical/performance tables are not merged into current page values. · Checked 2026-10-12
  • NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13

Reviewed marketed SKU and UPC 048231379618; selected support LT1016CER.AT1AUSL. Base model is not an alias of every historical sales suffix.

Manufacturer specifications ↗
More checks neededLG

LT12124CNR

Power: 115 V operation documented

Next check: A manufacturer-documented sleeve for a new installation is not in this catalog.

Nominal supply
115 V
Cooling at 115 V
11,800 BTU/h
Heating
Cooling only
Plug
NEMA 5-15P
Specified circuit / fuse
15 A
CEER at 115 V
10.5

Reported indoor noise: 60 dBA (Manufacturer rating; fan speed and test conditions not stated). Test conditions vary by source.

What matches (1)
  • 115 V operation is documented.
Checks before purchase (5)
  • A manufacturer-documented sleeve for a new installation is not in this catalog.
  • Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
  • Exact plug/receptacle configuration needs confirmation.
  • Room estimate or model capacity at the selected voltage needs checking.
  • Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.

Seller availability unverified for this exact model.

Sleeves, required parts and sources

No sleeve relationship has been established under your installation answers.

Evidence for this model and installation

  • LG US wall air conditioner category ↗Eleven LT equipment entries observed in initial category HTML; accessories excluded. Dynamic pagination is not proof of complete coverage. · Checked 2026-10-12
  • LG owner manual — cool ↗Support associations checked 2026-10-12; visually reviewed 2026-10-13. Printed/PDF page 9 explicitly lists LT0816CER, LT1016CER, LT12124CNR (115 V) and LT1036CER, LT1236CER, LT1430CNR (230 V), 15 A circuit and outlet drawings; pages 11–13 packing list and LGE sleeve Procedure A. LT1216CER has a separate exact support manual. Printed pages 12 and 15–16 cover the 27 × 16-3/4 × 16-3/4 in Friedrich housing under existing-sleeve Procedure C. · Checked 2026-11-22
  • LG LT12124CNR — current product specifications ↗Specifications > Electrical Ratings, Performance, Features and Dimensions/Weight; public page specification data; product modelStatus ACTIVE checked separately from stock. · Checked 2026-10-13
  • LG LT12124CNR — exact support/document association ↗Selected support sales suffix and Download Manuals list; suffix is not automatically an alias of another physical generation. · Checked 2026-10-12
  • NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13

Reviewed marketed SKU and UPC 048231607261; selected support LT12124CNR.AT1AYOW. Base model is not an alias of every historical sales suffix.

Manufacturer specifications ↗
More checks neededLG

LT1216CER

Power: 115 V operation documented

Next check: No positive manufacturer sleeve decision is available under these answers.

Nominal supply
115 V
Cooling at 115 V
11,800 BTU/h
Heating
Cooling only
Plug
NEMA 5-15P
Specified circuit / fuse
15 A
CEER at 115 V
10.5

Reported indoor noise: 60 dBA (Manufacturer rating; fan speed and test conditions not stated). Test conditions vary by source.

What matches (1)
  • 115 V operation is documented.
Checks before purchase (5)
  • No positive manufacturer sleeve decision is available under these answers.
  • Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
  • Exact plug/receptacle configuration needs confirmation.
  • Room estimate or model capacity at the selected voltage needs checking.
  • Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.

Seller availability unverified for this exact model.

Sleeves, required parts and sources

LG AXSVA1

Sleeve decision needs review.

Provided installation hardware; apply exact sleeve procedure · Required for the listed procedure · Included as reported in source

  • The current exact-model sheet does not name AXSVA1/AXSVA4. The associated manual describes an LGE sleeve and Procedure A. This generic description and matching dimensions do not establish this exact part/model relation.
  • The model-associated manual supplies grille/insulation/shims/trim and describes LGE Procedure A. Follow the exact sleeve procedure and rearward slope; this is not independent evidence identifying this sleeve SKU.

LG AXSVA4

Sleeve decision needs review.

Provided installation hardware; apply exact sleeve procedure · Required for the listed procedure · Included as reported in source

  • The current exact-model sheet does not name AXSVA1/AXSVA4. The associated manual describes an LGE sleeve and Procedure A. This generic description and matching dimensions do not establish this exact part/model relation.
  • The model-associated manual supplies grille/insulation/shims/trim and describes LGE Procedure A. Follow the exact sleeve procedure and rearward slope; this is not independent evidence identifying this sleeve SKU.

Evidence for this model and installation

Reviewed marketed SKU and UPC 048231379632; selected support LT1216CER.AT1AHDS. Base model is not an alias of every historical sales suffix.

Manufacturer specifications ↗
More checks neededFriedrich

UCT08B10A

Sleeve: Friedrich USC, Friedrich USEZ documented

Power: 115 V operation documented

Next check: Compare the actual circuit with the exact manufacturer circuit/fuse requirement.

Nominal supply
115 V
Cooling at 115 V
8,000 BTU/h
Heating
Cooling only
Plug
NEMA 5-15P
Specified circuit / fuse
15 A
CEER at 115 V
10.1
Wi-Fi documented

Installation: Friedrich USC · required kit included; Friedrich USEZ · required kit included

Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.

What matches (2)
  • Documented sleeve option: Friedrich USC, Friedrich USEZ. Installation conditions apply.
  • 115 V operation is documented.
Checks before purchase (4)
  • Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
  • Exact plug/receptacle configuration needs confirmation.
  • Room estimate or model capacity at the selected voltage needs checking.
  • Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources

Friedrich USC

Manufacturer sleeve association; listed conditions apply.

Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source

Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source

  • The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
  • Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
  • Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.

Friedrich USEZ

Manufacturer sleeve association; listed conditions apply.

Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source

  • The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
  • Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
  • Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
  • Confirm the USEZ sleeve revision before cutting or reusing an opening. The October 1, 2024 USEZ installation drawing gives a minimum 26-1/4 × 15-3/4 in opening for the sleeve covered by that manual.
  • For the USEZ covered by the October 1, 2024 manual, follow page 3 for minimum indoor and outdoor projections, rearward pitch, rear grille and supports.

Evidence for this model and installation

UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25

Manufacturer specifications ↗
More checks neededFriedrich

UCT10B10A

Sleeve: Friedrich USC, Friedrich USEZ documented

Power: 115 V operation documented

Next check: Compare the actual circuit with the exact manufacturer circuit/fuse requirement.

Nominal supply
115 V
Cooling at 115 V
10,000 BTU/h
Heating
Cooling only
Plug
NEMA 5-15P
Specified circuit / fuse
15 A
CEER at 115 V
10.1
Wi-Fi documented

Installation: Friedrich USC · required kit included; Friedrich USEZ · required kit included

Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.

What matches (2)
  • Documented sleeve option: Friedrich USC, Friedrich USEZ. Installation conditions apply.
  • 115 V operation is documented.
Checks before purchase (4)
  • Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
  • Exact plug/receptacle configuration needs confirmation.
  • Room estimate or model capacity at the selected voltage needs checking.
  • Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources

Friedrich USC

Manufacturer sleeve association; listed conditions apply.

Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source

Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source

  • The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
  • Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
  • Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.

Friedrich USEZ

Manufacturer sleeve association; listed conditions apply.

Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source

  • The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
  • Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
  • Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
  • Confirm the USEZ sleeve revision before cutting or reusing an opening. The October 1, 2024 USEZ installation drawing gives a minimum 26-1/4 × 15-3/4 in opening for the sleeve covered by that manual.
  • For the USEZ covered by the October 1, 2024 manual, follow page 3 for minimum indoor and outdoor projections, rearward pitch, rear grille and supports.

Evidence for this model and installation

UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25

Manufacturer specifications ↗
More checks neededFriedrich

UCT12B10A

Sleeve: Friedrich USC, Friedrich USEZ documented

Power: 115 V operation documented

Next check: Compare the actual circuit with the exact manufacturer circuit/fuse requirement.

Nominal supply
115 V
Cooling at 115 V
12,000 BTU/h
Heating
Cooling only
Plug
NEMA 5-15P
Specified circuit / fuse
15 A
CEER at 115 V
10
Wi-Fi documented

Installation: Friedrich USC · required kit included; Friedrich USEZ · required kit included

Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.

What matches (2)
  • Documented sleeve option: Friedrich USC, Friedrich USEZ. Installation conditions apply.
  • 115 V operation is documented.
Checks before purchase (4)
  • Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
  • Exact plug/receptacle configuration needs confirmation.
  • Room estimate or model capacity at the selected voltage needs checking.
  • Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources

Friedrich USC

Manufacturer sleeve association; listed conditions apply.

Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source

Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source

  • The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
  • Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
  • Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.

Friedrich USEZ

Manufacturer sleeve association; listed conditions apply.

Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source

  • The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
  • Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
  • Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
  • Confirm the USEZ sleeve revision before cutting or reusing an opening. The October 1, 2024 USEZ installation drawing gives a minimum 26-1/4 × 15-3/4 in opening for the sleeve covered by that manual.
  • For the USEZ covered by the October 1, 2024 manual, follow page 3 for minimum indoor and outdoor projections, rearward pitch, rear grille and supports.

Evidence for this model and installation

UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25

Manufacturer specifications ↗
More checks neededFriedrich

UET08B11A

Sleeve: Friedrich USC, Friedrich USEZ documented

Power: 115 V operation documented

Next check: Compare the actual circuit with the exact manufacturer circuit/fuse requirement.

Nominal supply
115 V
Cooling at 115 V
8,000 BTU/h
Heating
Electric heat
Plug
NEMA 5-15P
Specified circuit / fuse
15 A
CEER at 115 V
9.6
Wi-Fi documented

Installation: Friedrich USC · required kit included; Friedrich USEZ · required kit included

Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.

What matches (2)
  • Documented sleeve option: Friedrich USC, Friedrich USEZ. Installation conditions apply.
  • 115 V operation is documented.
Checks before purchase (4)
  • Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
  • Exact plug/receptacle configuration needs confirmation.
  • Room estimate or model capacity at the selected voltage needs checking.
  • Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources

Friedrich USC

Manufacturer sleeve association; listed conditions apply.

Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source

Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source

  • The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
  • Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
  • Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.

Friedrich USEZ

Manufacturer sleeve association; listed conditions apply.

Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source

  • The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
  • Use included trim ring and applicable sealing/grille components according to the exact R-32 manual. Remove weather panels before operation.
  • Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
  • Confirm the USEZ sleeve revision before cutting or reusing an opening. The October 1, 2024 USEZ installation drawing gives a minimum 26-1/4 × 15-3/4 in opening for the sleeve covered by that manual.
  • For the USEZ covered by the October 1, 2024 manual, follow page 3 for minimum indoor and outdoor projections, rearward pitch, rear grille and supports.

Evidence for this model and installation

UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25

Manufacturer specifications ↗
More checks neededFriedrich

WCVT12B10B

Sleeve: Friedrich WSE documented

Power: 115 V operation documented

Next check: Compare the actual circuit with the exact manufacturer circuit/fuse requirement.

Nominal supply
115 V
Cooling at 115 V
Not established
Heating
Cooling only
Plug
NEMA 5-15P
Specified circuit / fuse
15 A
CEER at 115 V
Not established
Inverter documentedWi-Fi documented

Installation: Friedrich WSE · follow listed conditions

What matches (2)
  • Documented sleeve option: Friedrich WSE. Installation conditions apply.
  • 115 V operation is documented.
Checks before purchase (4)
  • Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
  • Exact plug/receptacle configuration needs confirmation.
  • Room estimate or model capacity at the selected voltage needs checking.
  • Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.

Seller availability unverified for this exact model.

Sleeves, required parts and sources

Friedrich WSE

Manufacturer sleeve association; listed conditions apply.

External condensate drain kit (DK) · Optional or conditional · Package inclusion not established

  • Confirm an actual WSE sleeve in serviceable condition. The exact B-suffix model appears in the brochure's installation table, whose note requires a WSE sleeve; dimensions alone are not the evidence for this relation.
  • Verify the rear grille against the manufacturer installation requirements. Incorrect airflow can recirculate discharge air and cause shutdown; do not assume an old grille is suitable.
  • Check the actual installation for this 115 V model, NEMA 5-15P plug and manufacturer-specified 15 A circuit/fuse. Cooling running current is a separate specification.
  • DK is an optional external drain kit when connection to a condensate disposal system is necessary or desired. It is not a general requirement for every WSE replacement.

Evidence for this model and installation

2026 WallMaster inverter / R-32, final B suffix (BR_WM_REV 07-15-25)

Manufacturer specifications ↗
Outside the current filters (25) — see why
  • AJCQ12DXXWADocumented nominal supply is 230 V; your answer is 115 V.
  • AJEQ12DCXWADocumented nominal supply is 230 V; your answer is 115 V.
  • AJVQ12DCXWADocumented nominal supply is 230 V; your answer is 115 V.
  • AKCQ12DXXXADocumented nominal supply is 230 V; your answer is 115 V.
  • AKVQ12DXXWADocumented nominal supply is 230 V; your answer is 115 V.
  • FHTC103WB2Documented nominal supply is 230 V; your answer is 115 V.
  • FHTC123WB2Documented nominal supply is 230 V; your answer is 115 V.
  • FHTC142WA2Documented nominal supply is 230 V; your answer is 115 V.
  • FHTE103WA2Documented nominal supply is 230 V; your answer is 115 V.
  • FHTE123WA2Documented nominal supply is 230 V; your answer is 115 V.
  • FHTE143WA2Documented nominal supply is 230 V; your answer is 115 V.
  • LT1033HNRDocumented nominal supply is 230 V; your answer is 115 V.
  • LT1036CERDocumented nominal supply is 230 V; your answer is 115 V.
  • LT1037HNRDocumented nominal supply is 230 V; your answer is 115 V.
  • LT1233HNRDocumented nominal supply is 230 V; your answer is 115 V.
  • LT1236CERDocumented nominal supply is 230 V; your answer is 115 V.
  • LT1237HNRDocumented nominal supply is 230 V; your answer is 115 V.
  • LT1430CNRDocumented nominal supply is 230 V; your answer is 115 V.
  • UCT10B30ADocumented nominal supply is 230 V; your answer is 115 V.
  • UCT12B30ADocumented nominal supply is 230 V; your answer is 115 V.
  • UCT14B30ADocumented nominal supply is 230 V; your answer is 115 V.
  • UET10B33ADocumented nominal supply is 230 V; your answer is 115 V.
  • UET12B33ADocumented nominal supply is 230 V; your answer is 115 V.
  • UET14B33ADocumented nominal supply is 230 V; your answer is 115 V.
  • WCVT16B30BDocumented nominal supply is 230 V; your answer is 115 V.

What 115 V establishes

19 profiles in this installation scope document 115 V operation. That does not check your receptacle or breaker. Select a heating type, then use the compact shortlist filters to compare the actual outlet, circuit and room estimate.

Manufacturer documents for this shortlist: WallMaster 2026 brochure — exact model specifications ↗ · WallMaster 2026 brochure — chassis and WSE sleeve ↗ · WallMaster 2026 brochure — electrical requirements ↗

What the shortlist can establish

Each result shows documented requirements, pending checks and known exclusions for the models reviewed. Use the listed checks to verify your installation before buying.

Sources behind this catalog selection (66)

Room sizing, supply and installation guide →