115-volt through-the-wall heat-pump air conditioners for new installations

Selected: A new installation · 115 V supply · Heat pump

Compare 115 V with heat pumps candidates with new-sleeve installation evidence. Refine by room area, outlet, circuit, inverter and Wi-Fi.

1 models still in consideration0 meet documented filters · 1 need checksSee models ↓

1 models still in consideration

The shortlist updates with each answer. Confirm room capacity, electrical supply and installation conditions before purchase. Seller stock and prices have not been checked.

Refine your shortlist

Circuit breaker / fuse
Sun, occupants and other sizing adjustments

Cooling estimate: needs a sizing check · ENERGY STAR chart ↗

Voltage, outlet configuration and circuit protection are separate checks. Missing or disputed feature data stays unconfirmed; indoor noise data is not a “quietest” ranking.

Catalog coverage (33 profiles)

More checks needed (1)

Unknown or disputed facts remain visible in each profile. These are candidates for verification, not installation approvals.

More checks neededGE

AJVQ12ACXWA

Nominal supply
115 V
Cooling at 115 V
12,000 BTU/h
Heating
Heat pump with electric backup
Plug
Not established
Specified circuit / fuse
Not established
CEER at 115 V
9.6
Inverter documentedWi-Fi documented

Installation: GE RAB26A · required kit included; GE RAB46B · required kit included

Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.

What matches (3)
  • Documented sleeve option: GE RAB26A, GE RAB46B. Installation conditions apply.
  • 115 V operation is documented.
  • Documented heating type meets your choice; heating output and operating limits still need assessment.
Verify circuit rating, plug, outlet
Why these facts need checking
  • Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
  • Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
  • Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (4)
  • The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
  • Exact plug/receptacle configuration needs confirmation.
  • Room estimate or model capacity at the selected voltage needs checking.
  • Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources

GE RAB26A

Manufacturer sleeve association; listed conditions apply.

Supplied security bracket and screws · Required for the listed procedure · Included as reported in source

  • The exact-model manual recommends RAB26A with the RAG13A rear grille. Use the full sleeve/chassis instructions.
  • Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
  • Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
  • Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
  • For a new installation the sleeve is purchased separately from the chassis.
  • For heat-capable models, apply all page-16 combustible-material clearances: sides 1 in, front and exterior rear 20 in, above 39-3/8 in, below as the manual’s 4-7/8–6-3/8 in range. Resolve the applicable bottom clearance for the actual installation; do not select an endpoint as a general rule.

GE RAB46B

Manufacturer sleeve association; listed conditions apply.

Supplied security bracket and screws · Required for the listed procedure · Included as reported in source

  • The exact-model manual recommends RAB46B with the RAG13A rear grille. Use the full sleeve/chassis instructions.
  • Confirm specified rear grille and airflow. A retained louvered grille must follow the 45-degree instruction; do not substitute a grille by dimensions.
  • Install the supplied security bracket with its flange behind the sleeve edge, as specified on printed page 16.
  • Confirm exact unit nameplate, grounded outlet and circuit; remaining unknown electrical fields must be resolved before recommendation.
  • For a new installation the sleeve is purchased separately from the chassis.
  • For heat-capable models, apply all page-16 combustible-material clearances: sides 1 in, front and exterior rear 20 in, above 39-3/8 in, below as the manual’s 4-7/8–6-3/8 in range. Resolve the applicable bottom clearance for the actual installation; do not select an endpoint as a general rule.

Evidence for this model and installation

  • GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
  • GE AJVQ12ACXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
  • GE AJVQ12ACXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13

2025/2026 inverter generation; exact full SKU covered by 49-5001195

Manufacturer specifications ↗
Outside the current filters (32) — see why
  • AJCQ08AXXWADocumented heating type does not meet your heating choice.
  • AJCQ12AXXWADocumented heating type does not meet your heating choice.
  • AJCQ12DXXWADocumented nominal supply is 230 V; your answer is 115 V. Documented heating type does not meet your heating choice.
  • AJEQ12DCXWADocumented nominal supply is 230 V; your answer is 115 V. Documented heating type does not meet your heating choice.
  • AJVQ12DCXWADocumented nominal supply is 230 V; your answer is 115 V.
  • AKCQ08AXXXADocumented heating type does not meet your heating choice.
  • AKCQ12AXXXADocumented heating type does not meet your heating choice.
  • AKCQ12DXXXADocumented nominal supply is 230 V; your answer is 115 V. Documented heating type does not meet your heating choice.
  • AKVQ12DXXWADocumented nominal supply is 230 V; your answer is 115 V.
  • LT0816CERDocumented heating type does not meet your heating choice.
  • LT1016CERDocumented heating type does not meet your heating choice.
  • LT1033HNRDocumented nominal supply is 230 V; your answer is 115 V. Documented heating type does not meet your heating choice.
  • LT1036CERDocumented nominal supply is 230 V; your answer is 115 V. Documented heating type does not meet your heating choice.
  • LT1037HNRDocumented nominal supply is 230 V; your answer is 115 V. Documented heating type does not meet your heating choice.
  • LT12124CNRDocumented heating type does not meet your heating choice.
  • LT1216CERDocumented heating type does not meet your heating choice.
  • LT1233HNRDocumented nominal supply is 230 V; your answer is 115 V. Documented heating type does not meet your heating choice.
  • LT1236CERDocumented nominal supply is 230 V; your answer is 115 V. Documented heating type does not meet your heating choice.
  • LT1237HNRDocumented nominal supply is 230 V; your answer is 115 V. Documented heating type does not meet your heating choice.
  • LT1430CNRDocumented nominal supply is 230 V; your answer is 115 V. Documented heating type does not meet your heating choice.
  • UCT08B10ADocumented heating type does not meet your heating choice.
  • UCT10B10ADocumented heating type does not meet your heating choice.
  • UCT10B30ADocumented nominal supply is 230 V; your answer is 115 V. Documented heating type does not meet your heating choice.
  • UCT12B10ADocumented heating type does not meet your heating choice.
  • UCT12B30ADocumented nominal supply is 230 V; your answer is 115 V. Documented heating type does not meet your heating choice.
  • UCT14B30ADocumented nominal supply is 230 V; your answer is 115 V. Documented heating type does not meet your heating choice.
  • UET08B11ADocumented heating type does not meet your heating choice.
  • UET10B33ADocumented nominal supply is 230 V; your answer is 115 V. Documented heating type does not meet your heating choice.
  • UET12B33ADocumented nominal supply is 230 V; your answer is 115 V. Documented heating type does not meet your heating choice.
  • UET14B33ADocumented nominal supply is 230 V; your answer is 115 V. Documented heating type does not meet your heating choice.
  • WCVT12B10BDocumented heating type does not meet your heating choice.
  • WCVT16B30BDocumented nominal supply is 230 V; your answer is 115 V. Documented heating type does not meet your heating choice.

Check the heat pump’s operating limits

Heat-pump performance depends on outdoor conditions. Check the exact unit’s operating-temperature limits, heating output and any electric backup. The presence of a heat pump does not establish suitability as the room’s sole heating source.

Manufacturer documents for this shortlist: GE 26-inch inverter owner and installation manual ↗ · GE AJVQ12ACXWA — manufacturing dates ↗ · GE AJVQ12ACXWA — exact product specifications ↗

What the shortlist can establish

The engine separates documented requirements, missing or disputed facts and known exclusions. Models marked “More checks needed” are not purchase approvals. This is a limited catalog of Friedrich, LG and GE; it does not cover every available wall air conditioner.

Sources behind this catalog selection (3)
  • GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
  • GE AJVQ12ACXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
  • GE AJVQ12ACXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13

Room sizing, supply and installation guide →