IDENTIFY YOUR EXISTING SLEEVE

What fits the Friedrich WSE sleeve?

The assembled Friedrich WSE sleeve. This pilot documents replacement with the listed R-32 Uni-Fit units; additional reviewed WallMaster candidates remain unpublished and affected source conflicts are explicit. Confirm the actual sleeve identity and condition.

28 documented options. 26 with required kit included.

Confirm this is your actual sleeve. Each option has separate installation and electrical requirements.

How to identify it

  • Confirm WSE on the sleeve documentation or label. The assembled WSE and the knock-down WSEZ are separately named products; this record covers WSE.Source 4
  • The brochure lists the WSE housing as 27 in wide × 16.75 in high × 16.75 in deep. These are sleeve dimensions, not a measured internal clearance or proof of compatibility.Source 2
  • WSE is sold with an expanded-metal grille for WallMaster installations. The reviewed Uni-Fit replacement procedure instead requires its specified dual-intake grille; follow the model-specific relationship below rather than retaining the old grille.Source 4Source 13

Dimensions: three different measurements

Interior dimensions, outside sleeve dimensions and the wall opening are different. These values describe the equipment; they do not prove fit.

Interior width
Not documented
Interior height
Not documented
Interior depth
Not documented
External width
27 inSource 2
External height
16.75 inSource 2
External depth
16.75 inSource 2
Wall opening width
27.25 inSource 2
Wall opening height
17.25 inSource 2

Replacement options

Replacement options and documented installation requirements
ModelFit statusCoolingElectrical requirementsRequired / conditional partsWhat to check
Friedrich WCVT12B10B2026 WallMaster inverter / R-32, final B suffix (BR_WM_REV 07-15-25)Availability not checkedDocumented fit — conditions applySleeve: Friedrich WSESource 2Source 3Source 4Sources disagreeSource 1Source 135115 VSource 1PlugNEMA 5-15PSource 3ReceptacleNEMA 5-15RSource 3Source 119Specified circuit / fuse15 ASource 3
  • External condensate drain kitPart number: DKOnly if the stated condition appliesSource 4Package: Not documented
4 installation checks
  • Confirm an actual WSE sleeve in serviceable condition. The exact B-suffix model appears in the brochure's installation table, whose note requires a WSE sleeve; dimensions alone are not the evidence for this relation.Source 2
  • Verify the rear grille against the manufacturer installation requirements. Incorrect airflow can recirculate discharge air and cause shutdown; do not assume an old grille is suitable.Source 4
  • Check the actual installation for this 115 V model, NEMA 5-15P plug and manufacturer-specified 15 A circuit/fuse. Cooling running current is a separate specification.Source 1Source 3
  • DK is an optional external drain kit when connection to a condensate disposal system is necessary or desired. It is not a general requirement for every WSE replacement.Source 4
Friedrich WCVT16B30B2026 WallMaster inverter / R-32, final B suffix (BR_WM_REV 07-15-25)Availability not checkedDocumented fit — conditions applySleeve: Friedrich WSESource 2Source 3Source 416,800 BTU/hSource 1230 VSource 1PlugNEMA 6-15PSource 3ReceptacleNEMA 6-15RSource 3Source 119Specified circuit / fuse15 ASource 3
  • External condensate drain kitPart number: DKOnly if the stated condition appliesSource 4Package: Not documented
4 installation checks
  • Confirm an actual WSE sleeve in serviceable condition. The exact B-suffix model appears in the brochure's installation table, whose note requires a WSE sleeve; dimensions alone are not the evidence for this relation.Source 2
  • Verify the rear grille against the manufacturer installation requirements. Incorrect airflow can recirculate discharge air and cause shutdown; do not assume an old grille is suitable.Source 4
  • Check the actual installation for this 230 V model, NEMA 6-15P plug and manufacturer-specified 15 A circuit/fuse. Cooling running current is a separate specification.Source 1Source 3
  • DK is an optional external drain kit when connection to a condensate disposal system is necessary or desired. It is not a general requirement for every WSE replacement.Source 4
GE AKCQ08AXXXA2025/2026 inverter generation; exact full SKU covered by 49-5001293Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 2Source 527,800 BTU/hSource 92115 VSource 92PlugNEMA 5-15PSource 92ReceptacleNEMA 5-15RSource 52Source 92Source 119Specified circuit / fuseNot documented
  • Supplied rear louvered panel, supports, seals and ground wirePart number: Not documentedRequired under the listed conditionsSource 52Package: Included in the unit package — install as specified
3 installation checks
  • For an existing, sound Friedrich WSE matching the 27 × 16-3/4 × 16-3/4 in Friedrich housing in the AC installation manual. Confirm the sleeve label, dimensions and condition.Source 2Source 52
  • Follow the GE instructions for a 16-3/4 in deep Friedrich sleeve, including replacement of the rear grille with the supplied louvered panel and the specified supports, seals and grounding.Source 52
  • Verify the exact AC nameplate, grounded outlet, circuit and room size before purchase.Source 52
GE AKCQ12AXXXA2025/2026 inverter generation; exact full SKU covered by 49-5001293Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 2Source 5212,000 BTU/hSource 98115 VSource 98PlugNEMA 5-15PSource 98ReceptacleNEMA 5-15RSource 52Source 98Source 119Specified circuit / fuseNot documented
  • Supplied rear louvered panel, supports, seals and ground wirePart number: Not documentedRequired under the listed conditionsSource 52Package: Included in the unit package — install as specified
3 installation checks
  • For an existing, sound Friedrich WSE matching the 27 × 16-3/4 × 16-3/4 in Friedrich housing in the AC installation manual. Confirm the sleeve label, dimensions and condition.Source 2Source 52
  • Follow the GE instructions for a 16-3/4 in deep Friedrich sleeve, including replacement of the rear grille with the supplied louvered panel and the specified supports, seals and grounding.Source 52
  • Verify the exact AC nameplate, grounded outlet, circuit and room size before purchase.Source 52
Frigidaire FHTC103WB1Frigidaire R-32 built-in wall AC / specification edition 02/25Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 2Source 148Source 15010,000 BTU/hSource 150115 VSource 150PlugNot documentedReceptacleNot documentedSpecified circuit / fuseNot documented
  • Supplied dual-intake rear grille, seals and grounding partsPart number: Not documentedRequired under the listed conditionsSource 148Package: Included in the unit package — install as specified
  • Optional larger front trim for an existing sleevePart number: EA120TOnly if the stated condition appliesSource 148Package: Not included — obtain separately if needed
4 installation checks
  • For an existing, sound Friedrich WSE. Confirm its label and the 27 × 16-3/4 × 16-3/4 in dimensions. Frigidaire lists WSE by name in the existing sleeve table.Source 2Source 148
  • Follow the existing-sleeve instructions for the dual-intake rear grille, mounting, seals, slope and grounding. Review the rear grille attachment before reusing the sleeve.Source 148
  • EA120T is the larger front trim Frigidaire lists for larger existing sleeves. Check whether the existing installation needs this trim before ordering.Source 148
  • Verify the exact unit nameplate, plug and circuit requirements for the actual installation.Source 150
Frigidaire FHTC103WB2Frigidaire R-32 built-in wall AC / specification edition 02/25Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 2Source 148Source 15210,000 BTU/hSource 152230 VSource 152PlugNot documentedReceptacleNot documentedSpecified circuit / fuseNot documented
  • Supplied dual-intake rear grille, seals and grounding partsPart number: Not documentedRequired under the listed conditionsSource 148Package: Included in the unit package — install as specified
  • Optional larger front trim for an existing sleevePart number: EA120TOnly if the stated condition appliesSource 148Package: Not included — obtain separately if needed
4 installation checks
  • For an existing, sound Friedrich WSE. Confirm its label and the 27 × 16-3/4 × 16-3/4 in dimensions. Frigidaire lists WSE by name in the existing sleeve table.Source 2Source 148
  • Follow the existing-sleeve instructions for the dual-intake rear grille, mounting, seals, slope and grounding. Review the rear grille attachment before reusing the sleeve.Source 148
  • EA120T is the larger front trim Frigidaire lists for larger existing sleeves. Check whether the existing installation needs this trim before ordering.Source 148
  • Verify the exact unit nameplate, plug and circuit requirements for the actual installation.Source 152
Frigidaire FHTC123WB1Frigidaire R-32 built-in wall AC / specification edition 02/25Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 2Source 148Source 15112,000 BTU/hSource 151115 VSource 151PlugNot documentedReceptacleNot documentedSpecified circuit / fuseNot documented
  • Supplied dual-intake rear grille, seals and grounding partsPart number: Not documentedRequired under the listed conditionsSource 148Package: Included in the unit package — install as specified
  • Optional larger front trim for an existing sleevePart number: EA120TOnly if the stated condition appliesSource 148Package: Not included — obtain separately if needed
4 installation checks
  • For an existing, sound Friedrich WSE. Confirm its label and the 27 × 16-3/4 × 16-3/4 in dimensions. Frigidaire lists WSE by name in the existing sleeve table.Source 2Source 148
  • Follow the existing-sleeve instructions for the dual-intake rear grille, mounting, seals, slope and grounding. Review the rear grille attachment before reusing the sleeve.Source 148
  • EA120T is the larger front trim Frigidaire lists for larger existing sleeves. Check whether the existing installation needs this trim before ordering.Source 148
  • Verify the exact unit nameplate, plug and circuit requirements for the actual installation.Source 151
Frigidaire FHTC123WB2Frigidaire R-32 built-in wall AC / specification edition 02/25Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 2Source 148Source 15312,000 BTU/hSource 153230 VSource 153PlugNot documentedReceptacleNot documentedSpecified circuit / fuseNot documented
  • Supplied dual-intake rear grille, seals and grounding partsPart number: Not documentedRequired under the listed conditionsSource 148Package: Included in the unit package — install as specified
  • Optional larger front trim for an existing sleevePart number: EA120TOnly if the stated condition appliesSource 148Package: Not included — obtain separately if needed
4 installation checks
  • For an existing, sound Friedrich WSE. Confirm its label and the 27 × 16-3/4 × 16-3/4 in dimensions. Frigidaire lists WSE by name in the existing sleeve table.Source 2Source 148
  • Follow the existing-sleeve instructions for the dual-intake rear grille, mounting, seals, slope and grounding. Review the rear grille attachment before reusing the sleeve.Source 148
  • EA120T is the larger front trim Frigidaire lists for larger existing sleeves. Check whether the existing installation needs this trim before ordering.Source 148
  • Verify the exact unit nameplate, plug and circuit requirements for the actual installation.Source 153
Frigidaire FHTC142WA2Frigidaire R-32 built-in wall AC / specification edition 02/25Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 2Source 148Source 15414,000 BTU/hSource 154230 VSource 154PlugNot documentedReceptacleNot documentedSpecified circuit / fuseNot documented
  • Supplied dual-intake rear grille, seals and grounding partsPart number: Not documentedRequired under the listed conditionsSource 148Package: Included in the unit package — install as specified
  • Optional larger front trim for an existing sleevePart number: EA120TOnly if the stated condition appliesSource 148Package: Not included — obtain separately if needed
4 installation checks
  • For an existing, sound Friedrich WSE. Confirm its label and the 27 × 16-3/4 × 16-3/4 in dimensions. Frigidaire lists WSE by name in the existing sleeve table.Source 2Source 148
  • Follow the existing-sleeve instructions for the dual-intake rear grille, mounting, seals, slope and grounding. Review the rear grille attachment before reusing the sleeve.Source 148
  • EA120T is the larger front trim Frigidaire lists for larger existing sleeves. Check whether the existing installation needs this trim before ordering.Source 148
  • Verify the exact unit nameplate, plug and circuit requirements for the actual installation.Source 154
Frigidaire FHTE083WA1Frigidaire R-32 built-in wall AC / specification edition 11/24Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 2Source 149Source 1558,000 BTU/hSource 155115 VSource 155PlugNot documentedReceptacleNot documentedSpecified circuit / fuseNot documented
  • Supplied dual-intake rear grille, seals and grounding partsPart number: Not documentedRequired under the listed conditionsSource 149Package: Included in the unit package — install as specified
  • Optional larger front trim for an existing sleevePart number: EA120TOnly if the stated condition appliesSource 149Package: Not included — obtain separately if needed
4 installation checks
  • For an existing, sound Friedrich WSE. Confirm its label and the 27 × 16-3/4 × 16-3/4 in dimensions. Frigidaire lists WSE by name in the existing sleeve table.Source 2Source 149
  • Follow the existing-sleeve instructions for the dual-intake rear grille, mounting, seals, slope and grounding. Review the rear grille attachment before reusing the sleeve.Source 149
  • EA120T is the larger front trim Frigidaire lists for larger existing sleeves. Check whether the existing installation needs this trim before ordering.Source 149
  • Verify the exact unit nameplate, plug and circuit requirements for the actual installation.Source 155
Frigidaire FHTE103WA2Frigidaire R-32 built-in wall AC / specification edition 11/24Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 2Source 149Source 15610,000 BTU/hSource 156230 VSource 156PlugNot documentedReceptacleNot documentedSpecified circuit / fuseNot documented
  • Supplied dual-intake rear grille, seals and grounding partsPart number: Not documentedRequired under the listed conditionsSource 149Package: Included in the unit package — install as specified
  • Optional larger front trim for an existing sleevePart number: EA120TOnly if the stated condition appliesSource 149Package: Not included — obtain separately if needed
4 installation checks
  • For an existing, sound Friedrich WSE. Confirm its label and the 27 × 16-3/4 × 16-3/4 in dimensions. Frigidaire lists WSE by name in the existing sleeve table.Source 2Source 149
  • Follow the existing-sleeve instructions for the dual-intake rear grille, mounting, seals, slope and grounding. Review the rear grille attachment before reusing the sleeve.Source 149
  • EA120T is the larger front trim Frigidaire lists for larger existing sleeves. Check whether the existing installation needs this trim before ordering.Source 149
  • Verify the exact unit nameplate, plug and circuit requirements for the actual installation.Source 156
Frigidaire FHTE123WA2Frigidaire R-32 built-in wall AC / specification edition 11/24Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 2Source 149Source 15712,000 BTU/hSource 157230 VSource 157PlugNot documentedReceptacleNot documentedSpecified circuit / fuseNot documented
  • Supplied dual-intake rear grille, seals and grounding partsPart number: Not documentedRequired under the listed conditionsSource 149Package: Included in the unit package — install as specified
  • Optional larger front trim for an existing sleevePart number: EA120TOnly if the stated condition appliesSource 149Package: Not included — obtain separately if needed
4 installation checks
  • For an existing, sound Friedrich WSE. Confirm its label and the 27 × 16-3/4 × 16-3/4 in dimensions. Frigidaire lists WSE by name in the existing sleeve table.Source 2Source 149
  • Follow the existing-sleeve instructions for the dual-intake rear grille, mounting, seals, slope and grounding. Review the rear grille attachment before reusing the sleeve.Source 149
  • EA120T is the larger front trim Frigidaire lists for larger existing sleeves. Check whether the existing installation needs this trim before ordering.Source 149
  • Verify the exact unit nameplate, plug and circuit requirements for the actual installation.Source 157
Frigidaire FHTE143WA2Frigidaire R-32 built-in wall AC / specification edition 11/24Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 2Source 149Source 15814,000 BTU/hSource 158230 VSource 158PlugNot documentedReceptacleNot documentedSpecified circuit / fuseNot documented
  • Supplied dual-intake rear grille, seals and grounding partsPart number: Not documentedRequired under the listed conditionsSource 149Package: Included in the unit package — install as specified
  • Optional larger front trim for an existing sleevePart number: EA120TOnly if the stated condition appliesSource 149Package: Not included — obtain separately if needed
4 installation checks
  • For an existing, sound Friedrich WSE. Confirm its label and the 27 × 16-3/4 × 16-3/4 in dimensions. Frigidaire lists WSE by name in the existing sleeve table.Source 2Source 149
  • Follow the existing-sleeve instructions for the dual-intake rear grille, mounting, seals, slope and grounding. Review the rear grille attachment before reusing the sleeve.Source 149
  • EA120T is the larger front trim Frigidaire lists for larger existing sleeves. Check whether the existing installation needs this trim before ordering.Source 149
  • Verify the exact unit nameplate, plug and circuit requirements for the actual installation.Source 158
Keystone KSTAT08-1DKeystone D-series through-the-wall room ACAvailability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 2Source 141Source 1428,000 BTU/hSource 139115 VSource 139PlugNEMA 5-15PSource 140ReceptacleNEMA 5-15RSource 119Source 140Specified circuit / fuseNot documented
  • Supplied rear grille, supports, seals, grounding wire and trimPart number: Not documentedRequired under the listed conditionsSource 141Package: Included in the unit package — install as specified
3 installation checks
  • Confirm an existing, sound Friedrich WSE matching the 27 × 16-3/4 × 16-3/4 in Friedrich housing in the AC installation chart.Source 2Source 141
  • Use the Friedrich/Fedders #3 existing-sleeve procedure. Replace the rear grille with the supplied grille and use the specified supports, seals, grounding and trim.Source 141
  • Confirm the circuit rating and dedicated supply for the exact production unit.Source 142
Keystone KSTAT12-1DKeystone D-series through-the-wall room ACAvailability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 2Source 144Source 14512,000 BTU/hSource 139115 VSource 139PlugNEMA 5-15PSource 143ReceptacleNEMA 5-15RSource 119Source 143Specified circuit / fuseNot documented
  • Supplied rear grille, supports, seals, grounding wire and trimPart number: Not documentedRequired under the listed conditionsSource 144Package: Included in the unit package — install as specified
3 installation checks
  • Confirm an existing, sound Friedrich WSE matching the 27 × 16-3/4 × 16-3/4 in Friedrich housing in the AC installation chart.Source 2Source 144
  • Use the Friedrich/Fedders #3 existing-sleeve procedure. Replace the rear grille with the supplied grille and use the specified supports, seals, grounding and trim.Source 144
  • Confirm the circuit rating and dedicated supply for the exact production unit.Source 145
LG LT12124CNRReviewed marketed SKU and UPC 048231607261; selected support LT12124CNR.AT1AYOW. Base model is not an alias of every historical sales suffix.Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 2Source 1811,800 BTU/hSource 35115 VSource 35PlugNEMA 5-15PSource 18Source 119ReceptacleNEMA 5-15RSource 18Source 119Specified circuit / fuse15 ASource 18
  • Supplied insulation, shims and trim; use the rear grille as directedPart number: Not documentedRequired under the listed conditionsSource 18Package: Included in the unit package — install as specified
3 installation checks
  • For an existing, sound Friedrich WSE matching the 27 × 16-3/4 × 16-3/4 in Friedrich housing in the AC installation manual. Confirm the sleeve label, dimensions and condition.Source 2Source 18
  • Follow LG’s existing-sleeve Procedure C for the 16-3/4 in deep Friedrich housing. Verify rear grille and louver configuration and use the supplied grille if the existing one is absent, as specified in the manual.Source 18
  • Verify the exact AC nameplate, grounded outlet, circuit and room size before purchase.Source 18
LG LT1216CERReviewed marketed SKU and UPC 048231379632; selected support LT1216CER.AT1AHDS. Base model is not an alias of every historical sales suffix.Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 2Source 12011,800 BTU/hSource 37115 VSource 37PlugNEMA 5-15PSource 119Source 120ReceptacleNEMA 5-15RSource 119Source 120Specified circuit / fuse15 ASource 120
  • Supplied insulation, shims and trim; use the rear grille as directedPart number: Not documentedRequired under the listed conditionsSource 120Package: Included in the unit package — install as specified
3 installation checks
  • For an existing, sound Friedrich WSE matching the 27 × 16-3/4 × 16-3/4 in Friedrich housing in the AC installation manual. Confirm the sleeve label, dimensions and condition.Source 2Source 120
  • Follow LG’s existing-sleeve Procedure C for the 16-3/4 in deep Friedrich housing. Verify rear grille and louver configuration and use the supplied grille if the existing one is absent, as specified in the manual.Source 120
  • Verify the exact AC nameplate, grounded outlet, circuit and room size before purchase.Source 120
LG LT1430CNRReviewed marketed SKU and UPC 048231604666; selected support LT1430CNR.AT3AUSB. Base model is not an alias of every historical sales suffix.Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 2Source 1814,000 BTU/hSource 49230 VSource 49PlugNEMA 6-15PSource 18Source 119ReceptacleNEMA 6-15RSource 18Source 119Specified circuit / fuse15 ASource 18
  • Supplied insulation, shims and trim; use the rear grille as directedPart number: Not documentedRequired under the listed conditionsSource 18Package: Included in the unit package — install as specified
3 installation checks
  • For an existing, sound Friedrich WSE matching the 27 × 16-3/4 × 16-3/4 in Friedrich housing in the AC installation manual. Confirm the sleeve label, dimensions and condition.Source 2Source 18
  • Follow LG’s existing-sleeve Procedure C for the 16-3/4 in deep Friedrich housing. Verify rear grille and louver configuration and use the supplied grille if the existing one is absent, as specified in the manual.Source 18
  • Verify the exact AC nameplate, grounded outlet, circuit and room size before purchase.Source 18
Friedrich UCT08B10AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 10Source 11Source 13Source 14Source 1088,000 BTU/hSource 9115 VSource 9PlugNEMA 5-15PSource 10ReceptacleNEMA 5-15RSource 14Specified circuit / fuse15 ASource 10
  • Provided Uni-Fit installation kit: specified dual-intake grille, seals and centering/grounding materials; confirm package contentsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
  • Included decorative trim ringPart number: Not documentedRequired under the listed conditionsSource 11Source 108Package: Included in the unit package — install as specified
5 installation checks
  • The current brochure and the exact-generation R-32 manual name Friedrich WSE among existing sleeves. Verify that the actual housing is securely installed and structurally sound; do not infer identity from a 27-inch measurement alone.Source 11Source 13
  • Use generic-sleeve Method B on printed page 16, with the specified dual-intake grille, sealing and centering materials and grounding wire. Remove the old rear grille. Optional Method A and architectural louver UXAA on page 15 are specified for USC, not this WSE procedure.Source 13
  • The manual describes a provided installation kit. Confirm that the exact unit package includes the required grille and seals; obtain manufacturer confirmation of replacement part numbers if these pieces are missing. No separate kit SKU is established in this record.Source 13Source 108
  • Use the included decorative trim ring to cover the gap around the smaller chassis. Follow the prescribed sealing and 3/8-inch downward slope from front to back; use the manual’s shimming procedure if needed.Source 11Source 13
  • Check the installation for the exact 115 V model, NEMA 5-15P plug, NEMA 5-15R receptacle and manufacturer-specified 15 A circuit/fuse. Do not derive the circuit from cooling running current.Source 10Source 14
Friedrich UCT10B10AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 10Source 11Source 13Source 14Source 10810,000 BTU/hSource 9115 VSource 9PlugNEMA 5-15PSource 10ReceptacleNEMA 5-15RSource 14Specified circuit / fuse15 ASource 10
  • Provided Uni-Fit installation kit: specified dual-intake grille, seals and centering/grounding materials; confirm package contentsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
  • Included decorative trim ringPart number: Not documentedRequired under the listed conditionsSource 11Source 108Package: Included in the unit package — install as specified
5 installation checks
  • The current brochure and the exact-generation R-32 manual name Friedrich WSE among existing sleeves. Verify that the actual housing is securely installed and structurally sound; do not infer identity from a 27-inch measurement alone.Source 11Source 13
  • Use generic-sleeve Method B on printed page 16, with the specified dual-intake grille, sealing and centering materials and grounding wire. Remove the old rear grille. Optional Method A and architectural louver UXAA on page 15 are specified for USC, not this WSE procedure.Source 13
  • The manual describes a provided installation kit. Confirm that the exact unit package includes the required grille and seals; obtain manufacturer confirmation of replacement part numbers if these pieces are missing. No separate kit SKU is established in this record.Source 13Source 108
  • Use the included decorative trim ring to cover the gap around the smaller chassis. Follow the prescribed sealing and 3/8-inch downward slope from front to back; use the manual’s shimming procedure if needed.Source 11Source 13
  • Check the installation for the exact 115 V model, NEMA 5-15P plug, NEMA 5-15R receptacle and manufacturer-specified 15 A circuit/fuse. Do not derive the circuit from cooling running current.Source 10Source 14
Friedrich UCT10B30AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 10Source 11Source 13Source 14Source 10810,000 BTU/hSource 9230 VSource 9PlugNEMA 6-15PSource 10ReceptacleNEMA 6-15RSource 14Specified circuit / fuse15 ASource 10
  • Provided Uni-Fit installation kit: specified dual-intake grille, seals and centering/grounding materials; confirm package contentsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
  • Included decorative trim ringPart number: Not documentedRequired under the listed conditionsSource 11Source 108Package: Included in the unit package — install as specified
5 installation checks
  • The current brochure and the exact-generation R-32 manual name Friedrich WSE among existing sleeves. Verify that the actual housing is securely installed and structurally sound; do not infer identity from a 27-inch measurement alone.Source 11Source 13
  • Use generic-sleeve Method B on printed page 16, with the specified dual-intake grille, sealing and centering materials and grounding wire. Remove the old rear grille. Optional Method A and architectural louver UXAA on page 15 are specified for USC, not this WSE procedure.Source 13
  • The manual describes a provided installation kit. Confirm that the exact unit package includes the required grille and seals; obtain manufacturer confirmation of replacement part numbers if these pieces are missing. No separate kit SKU is established in this record.Source 13Source 108
  • Use the included decorative trim ring to cover the gap around the smaller chassis. Follow the prescribed sealing and 3/8-inch downward slope from front to back; use the manual’s shimming procedure if needed.Source 11Source 13
  • Check the installation for the exact 230 V model, NEMA 6-15P plug, NEMA 6-15R receptacle and manufacturer-specified 15 A circuit/fuse. Do not derive the circuit from cooling running current.Source 10Source 14
Friedrich UCT12B10AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 10Source 11Source 13Source 14Source 10812,000 BTU/hSource 9115 VSource 9PlugNEMA 5-15PSource 10ReceptacleNEMA 5-15RSource 14Specified circuit / fuse15 ASource 10
  • Provided Uni-Fit installation kit: specified dual-intake grille, seals and centering/grounding materials; confirm package contentsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
  • Included decorative trim ringPart number: Not documentedRequired under the listed conditionsSource 11Source 108Package: Included in the unit package — install as specified
5 installation checks
  • The current brochure and the exact-generation R-32 manual name Friedrich WSE among existing sleeves. Verify that the actual housing is securely installed and structurally sound; do not infer identity from a 27-inch measurement alone.Source 11Source 13
  • Use generic-sleeve Method B on printed page 16, with the specified dual-intake grille, sealing and centering materials and grounding wire. Remove the old rear grille. Optional Method A and architectural louver UXAA on page 15 are specified for USC, not this WSE procedure.Source 13
  • The manual describes a provided installation kit. Confirm that the exact unit package includes the required grille and seals; obtain manufacturer confirmation of replacement part numbers if these pieces are missing. No separate kit SKU is established in this record.Source 13Source 108
  • Use the included decorative trim ring to cover the gap around the smaller chassis. Follow the prescribed sealing and 3/8-inch downward slope from front to back; use the manual’s shimming procedure if needed.Source 11Source 13
  • Check the installation for the exact 115 V model, NEMA 5-15P plug, NEMA 5-15R receptacle and manufacturer-specified 15 A circuit/fuse. Do not derive the circuit from cooling running current.Source 10Source 14
Friedrich UCT12B30AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 10Source 11Source 13Source 14Source 10812,000 BTU/hSource 9230 VSource 9PlugNEMA 6-15PSource 10ReceptacleNEMA 6-15RSource 14Specified circuit / fuse15 ASource 10
  • Provided Uni-Fit installation kit: specified dual-intake grille, seals and centering/grounding materials; confirm package contentsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
  • Included decorative trim ringPart number: Not documentedRequired under the listed conditionsSource 11Source 108Package: Included in the unit package — install as specified
5 installation checks
  • The current brochure and the exact-generation R-32 manual name Friedrich WSE among existing sleeves. Verify that the actual housing is securely installed and structurally sound; do not infer identity from a 27-inch measurement alone.Source 11Source 13
  • Use generic-sleeve Method B on printed page 16, with the specified dual-intake grille, sealing and centering materials and grounding wire. Remove the old rear grille. Optional Method A and architectural louver UXAA on page 15 are specified for USC, not this WSE procedure.Source 13
  • The manual describes a provided installation kit. Confirm that the exact unit package includes the required grille and seals; obtain manufacturer confirmation of replacement part numbers if these pieces are missing. No separate kit SKU is established in this record.Source 13Source 108
  • Use the included decorative trim ring to cover the gap around the smaller chassis. Follow the prescribed sealing and 3/8-inch downward slope from front to back; use the manual’s shimming procedure if needed.Source 11Source 13
  • Check the installation for the exact 230 V model, NEMA 6-15P plug, NEMA 6-15R receptacle and manufacturer-specified 15 A circuit/fuse. Do not derive the circuit from cooling running current.Source 10Source 14
Friedrich UCT14B30AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 10Source 11Source 13Source 14Source 10814,000 BTU/hSource 9230 VSource 9PlugNEMA 6-15PSource 10ReceptacleNEMA 6-15RSource 14Specified circuit / fuse15 ASource 10
  • Provided Uni-Fit installation kit: specified dual-intake grille, seals and centering/grounding materials; confirm package contentsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
  • Included decorative trim ringPart number: Not documentedRequired under the listed conditionsSource 11Source 108Package: Included in the unit package — install as specified
5 installation checks
  • The current brochure and the exact-generation R-32 manual name Friedrich WSE among existing sleeves. Verify that the actual housing is securely installed and structurally sound; do not infer identity from a 27-inch measurement alone.Source 11Source 13
  • Use generic-sleeve Method B on printed page 16, with the specified dual-intake grille, sealing and centering materials and grounding wire. Remove the old rear grille. Optional Method A and architectural louver UXAA on page 15 are specified for USC, not this WSE procedure.Source 13
  • The manual describes a provided installation kit. Confirm that the exact unit package includes the required grille and seals; obtain manufacturer confirmation of replacement part numbers if these pieces are missing. No separate kit SKU is established in this record.Source 13Source 108
  • Use the included decorative trim ring to cover the gap around the smaller chassis. Follow the prescribed sealing and 3/8-inch downward slope from front to back; use the manual’s shimming procedure if needed.Source 11Source 13
  • Check the installation for the exact 230 V model, NEMA 6-15P plug, NEMA 6-15R receptacle and manufacturer-specified 15 A circuit/fuse. Do not derive the circuit from cooling running current.Source 10Source 14
Friedrich UET08B11AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 10Source 11Source 13Source 14Source 1088,000 BTU/hSource 9115 VSource 9PlugNEMA 5-15PSource 10ReceptacleNEMA 5-15RSource 14Specified circuit / fuse15 ASource 10
  • Provided Uni-Fit installation kit: specified dual-intake grille, seals and centering/grounding materials; confirm package contentsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
  • Included decorative trim ringPart number: Not documentedRequired under the listed conditionsSource 11Source 108Package: Included in the unit package — install as specified
5 installation checks
  • The current brochure and the exact-generation R-32 manual name Friedrich WSE among existing sleeves. Verify that the actual housing is securely installed and structurally sound; do not infer identity from a 27-inch measurement alone.Source 11Source 13
  • Use generic-sleeve Method B on printed page 16, with the specified dual-intake grille, sealing and centering materials and grounding wire. Remove the old rear grille. Optional Method A and architectural louver UXAA on page 15 are specified for USC, not this WSE procedure.Source 13
  • The manual describes a provided installation kit. Confirm that the exact unit package includes the required grille and seals; obtain manufacturer confirmation of replacement part numbers if these pieces are missing. No separate kit SKU is established in this record.Source 13Source 108
  • Use the included decorative trim ring to cover the gap around the smaller chassis. Follow the prescribed sealing and 3/8-inch downward slope from front to back; use the manual’s shimming procedure if needed.Source 11Source 13
  • Check the installation for the exact 115 V model, NEMA 5-15P plug, NEMA 5-15R receptacle and manufacturer-specified 15 A circuit/fuse. Do not derive the circuit from cooling running current.Source 10Source 14
Friedrich UET10B33AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 10Source 11Source 13Source 14Source 10810,000 BTU/hSource 9230 VSource 9PlugNEMA 6-20PSource 10ReceptacleNEMA 6-20RSource 14Specified circuit / fuse20 ASource 10
  • Provided Uni-Fit installation kit: specified dual-intake grille, seals and centering/grounding materials; confirm package contentsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
  • Included decorative trim ringPart number: Not documentedRequired under the listed conditionsSource 11Source 108Package: Included in the unit package — install as specified
5 installation checks
  • The current brochure and the exact-generation R-32 manual name Friedrich WSE among existing sleeves. Verify that the actual housing is securely installed and structurally sound; do not infer identity from a 27-inch measurement alone.Source 11Source 13
  • Use generic-sleeve Method B on printed page 16, with the specified dual-intake grille, sealing and centering materials and grounding wire. Remove the old rear grille. Optional Method A and architectural louver UXAA on page 15 are specified for USC, not this WSE procedure.Source 13
  • The manual describes a provided installation kit. Confirm that the exact unit package includes the required grille and seals; obtain manufacturer confirmation of replacement part numbers if these pieces are missing. No separate kit SKU is established in this record.Source 13Source 108
  • Use the included decorative trim ring to cover the gap around the smaller chassis. Follow the prescribed sealing and 3/8-inch downward slope from front to back; use the manual’s shimming procedure if needed.Source 11Source 13
  • Check the installation for the exact 230 V model, NEMA 6-20P plug, NEMA 6-20R receptacle and manufacturer-specified 20 A circuit/fuse. Do not derive the circuit from cooling running current.Source 10Source 14
Friedrich UET12B33AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 10Source 11Source 13Source 14Source 10812,000 BTU/hSource 9230 VSource 9PlugNEMA 6-20PSource 10ReceptacleNEMA 6-20RSource 14Specified circuit / fuse20 ASource 10
  • Provided Uni-Fit installation kit: specified dual-intake grille, seals and centering/grounding materials; confirm package contentsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
  • Included decorative trim ringPart number: Not documentedRequired under the listed conditionsSource 11Source 108Package: Included in the unit package — install as specified
5 installation checks
  • The current brochure and the exact-generation R-32 manual name Friedrich WSE among existing sleeves. Verify that the actual housing is securely installed and structurally sound; do not infer identity from a 27-inch measurement alone.Source 11Source 13
  • Use generic-sleeve Method B on printed page 16, with the specified dual-intake grille, sealing and centering materials and grounding wire. Remove the old rear grille. Optional Method A and architectural louver UXAA on page 15 are specified for USC, not this WSE procedure.Source 13
  • The manual describes a provided installation kit. Confirm that the exact unit package includes the required grille and seals; obtain manufacturer confirmation of replacement part numbers if these pieces are missing. No separate kit SKU is established in this record.Source 13Source 108
  • Use the included decorative trim ring to cover the gap around the smaller chassis. Follow the prescribed sealing and 3/8-inch downward slope from front to back; use the manual’s shimming procedure if needed.Source 11Source 13
  • Check the installation for the exact 230 V model, NEMA 6-20P plug, NEMA 6-20R receptacle and manufacturer-specified 20 A circuit/fuse. Do not derive the circuit from cooling running current.Source 10Source 14
Friedrich UET14B33AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checkedKit included — install as specifiedSleeve: Friedrich WSESource 10Source 11Source 13Source 14Source 10814,000 BTU/hSource 9230 VSource 9PlugNEMA 6-20PSource 10ReceptacleNEMA 6-20RSource 14Specified circuit / fuse20 ASource 10
  • Provided Uni-Fit installation kit: specified dual-intake grille, seals and centering/grounding materials; confirm package contentsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
  • Included decorative trim ringPart number: Not documentedRequired under the listed conditionsSource 11Source 108Package: Included in the unit package — install as specified
5 installation checks
  • The current brochure and the exact-generation R-32 manual name Friedrich WSE among existing sleeves. Verify that the actual housing is securely installed and structurally sound; do not infer identity from a 27-inch measurement alone.Source 11Source 13
  • Use generic-sleeve Method B on printed page 16, with the specified dual-intake grille, sealing and centering materials and grounding wire. Remove the old rear grille. Optional Method A and architectural louver UXAA on page 15 are specified for USC, not this WSE procedure.Source 13
  • The manual describes a provided installation kit. Confirm that the exact unit package includes the required grille and seals; obtain manufacturer confirmation of replacement part numbers if these pieces are missing. No separate kit SKU is established in this record.Source 13Source 108
  • Use the included decorative trim ring to cover the gap around the smaller chassis. Follow the prescribed sealing and 3/8-inch downward slope from front to back; use the manual’s shimming procedure if needed.Source 11Source 13
  • Check the installation for the exact 230 V model, NEMA 6-20P plug, NEMA 6-20R receptacle and manufacturer-specified 20 A circuit/fuse. Do not derive the circuit from cooling running current.Source 10Source 14

Old models documented for this sleeve

Sources and review

Reviewed 2026-10-13.