Replacement research for the exact WCT08A10A: start with its documented electrical and cooling specifications, confirm the installed sleeve, then compare the options and their differences. Reassess the room requirements before buying.

Start by confirming your actual sleeve.

The old model number is a starting point. Confirm the sleeve marking and the requirements of the replacement before buying.

Closest published specifications for Friedrich WSE: UCT08B10A. See fit conditions and required parts below.

Your old model’s documented specifications

Nominal voltage
115 VSource 15
Cooling capacity
8,000 BTU/hSource 15
Plug
NEMA 5-15PSource 16
Required receptacle
NEMA 5-15RSource 16
Specified circuit / fuse
15 ASource 16
Heating type
Cooling onlySource 15

These are the manufacturer's model specifications. Confirm the actual outlet, circuit and room requirements; the installation may have changed.

Options for the Friedrich WSE sleeve

1 option is closest to the old model’s published specifications.

14 documented options. 12 with required kit included.

Fit is conditional on the requirements listed for each model. Sleeve fit is separate from matching the old unit’s specifications.

Old model → sleeve: The service manual names this exact WCT model. The installation manual specifies WSE for the WCT family. This association does not establish what is currently installed in an individual wall.Source 7Source 8

Closest to the old model’s published specifications

These options match the documented voltage, plug, circuit/fuse rating and heating type, with cooling capacity within 20% of the old unit. This is a comparison aid, not a room-sizing recommendation or a check of your actual outlet.

Replacement options and documented installation requirements
ModelFit statusCoolingElectrical requirementsRequired / conditional partsWhat to check
Friedrich UCT08B10AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checked

Matches the old model’s published voltage, plug, circuit/fuse and heating type.

  • Same published cooling capacity as the old unit; reassess the room requirements.
Kit included — install as specifiedSleeve: Friedrich WSESource 10Source 11Source 13Source 14Source 1088,000 BTU/hSource 9115 VSource 9PlugNEMA 5-15PSource 10ReceptacleNEMA 5-15RSource 14Specified circuit / fuse15 ASource 10
  • Provided Uni-Fit installation kit: specified dual-intake grille, seals and centering/grounding materials; confirm package contentsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
  • Included decorative trim ringPart number: Not documentedRequired under the listed conditionsSource 11Source 108Package: Included in the unit package — install as specified
5 installation checks
  • The current brochure and the exact-generation R-32 manual name Friedrich WSE among existing sleeves. Verify that the actual housing is securely installed and structurally sound; do not infer identity from a 27-inch measurement alone.Source 11Source 13
  • Use generic-sleeve Method B on printed page 16, with the specified dual-intake grille, sealing and centering materials and grounding wire. Remove the old rear grille. Optional Method A and architectural louver UXAA on page 15 are specified for USC, not this WSE procedure.Source 13
  • The manual describes a provided installation kit. Confirm that the exact unit package includes the required grille and seals; obtain manufacturer confirmation of replacement part numbers if these pieces are missing. No separate kit SKU is established in this record.Source 13Source 108
  • Use the included decorative trim ring to cover the gap around the smaller chassis. Follow the prescribed sealing and 3/8-inch downward slope from front to back; use the manual’s shimming procedure if needed.Source 11Source 13
  • Check the installation for the exact 115 V model, NEMA 5-15P plug, NEMA 5-15R receptacle and manufacturer-specified 15 A circuit/fuse. Do not derive the circuit from cooling running current.Source 10Source 14
Other 13 options — check differences

These may have different electrical or heating requirements, a larger capacity change, or missing evidence. Matching a sleeve alone does not make them a like-for-like replacement.

Replacement options and documented installation requirements
ModelFit statusCoolingElectrical requirementsRequired / conditional partsWhat to check
Friedrich WCVT16B30B2026 WallMaster inverter / R-32, final B suffix (BR_WM_REV 07-15-25)Availability not checked
  • Nominal voltage differs: old 115 V; replacement 230 V.
  • Plug differs: old NEMA 5-15P; replacement NEMA 6-15P.
  • 110.0% more published cooling capacity than the old unit; reassess the room requirements.
Documented fit — conditions applySleeve: Friedrich WSESource 2Source 3Source 416,800 BTU/hSource 1230 VSource 1PlugNEMA 6-15PSource 3ReceptacleNEMA 6-15RSource 3Source 119Specified circuit / fuse15 ASource 3
  • External condensate drain kitPart number: DKOnly if the stated condition appliesSource 4Package: Not documented
4 installation checks
  • Confirm an actual WSE sleeve in serviceable condition. The exact B-suffix model appears in the brochure's installation table, whose note requires a WSE sleeve; dimensions alone are not the evidence for this relation.Source 2
  • Verify the rear grille against the manufacturer installation requirements. Incorrect airflow can recirculate discharge air and cause shutdown; do not assume an old grille is suitable.Source 4
  • Check the actual installation for this 230 V model, NEMA 6-15P plug and manufacturer-specified 15 A circuit/fuse. Cooling running current is a separate specification.Source 1Source 3
  • DK is an optional external drain kit when connection to a condensate disposal system is necessary or desired. It is not a general requirement for every WSE replacement.Source 4
Friedrich WCVT12B10B2026 WallMaster inverter / R-32, final B suffix (BR_WM_REV 07-15-25)Availability not checked
  • Cooling capacity comparison not documented or disputed.
Documented fit — conditions applySleeve: Friedrich WSESource 2Source 3Source 4Sources disagreeSource 1Source 135115 VSource 1PlugNEMA 5-15PSource 3ReceptacleNEMA 5-15RSource 3Source 119Specified circuit / fuse15 ASource 3
  • External condensate drain kitPart number: DKOnly if the stated condition appliesSource 4Package: Not documented
4 installation checks
  • Confirm an actual WSE sleeve in serviceable condition. The exact B-suffix model appears in the brochure's installation table, whose note requires a WSE sleeve; dimensions alone are not the evidence for this relation.Source 2
  • Verify the rear grille against the manufacturer installation requirements. Incorrect airflow can recirculate discharge air and cause shutdown; do not assume an old grille is suitable.Source 4
  • Check the actual installation for this 115 V model, NEMA 5-15P plug and manufacturer-specified 15 A circuit/fuse. Cooling running current is a separate specification.Source 1Source 3
  • DK is an optional external drain kit when connection to a condensate disposal system is necessary or desired. It is not a general requirement for every WSE replacement.Source 4
Keystone KSTAT08-1DKeystone D-series through-the-wall room ACAvailability not checked
  • Specified circuit/fuse comparison not documented or disputed.
  • Same published cooling capacity as the old unit; reassess the room requirements.
Kit included — install as specifiedSleeve: Friedrich WSESource 2Source 141Source 1428,000 BTU/hSource 139115 VSource 139PlugNEMA 5-15PSource 140ReceptacleNEMA 5-15RSource 119Source 140Specified circuit / fuseNot documented
  • Supplied rear grille, supports, seals, grounding wire and trimPart number: Not documentedRequired under the listed conditionsSource 141Package: Included in the unit package — install as specified
3 installation checks
  • Confirm an existing, sound Friedrich WSE matching the 27 × 16-3/4 × 16-3/4 in Friedrich housing in the AC installation chart.Source 2Source 141
  • Use the Friedrich/Fedders #3 existing-sleeve procedure. Replace the rear grille with the supplied grille and use the specified supports, seals, grounding and trim.Source 141
  • Confirm the circuit rating and dedicated supply for the exact production unit.Source 142
Friedrich UET08B11AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checked
  • Heating type differs: old Cooling only; replacement Electric heat.
  • Same published cooling capacity as the old unit; reassess the room requirements.
Kit included — install as specifiedSleeve: Friedrich WSESource 10Source 11Source 13Source 14Source 1088,000 BTU/hSource 9115 VSource 9PlugNEMA 5-15PSource 10ReceptacleNEMA 5-15RSource 14Specified circuit / fuse15 ASource 10
  • Provided Uni-Fit installation kit: specified dual-intake grille, seals and centering/grounding materials; confirm package contentsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
  • Included decorative trim ringPart number: Not documentedRequired under the listed conditionsSource 11Source 108Package: Included in the unit package — install as specified
5 installation checks
  • The current brochure and the exact-generation R-32 manual name Friedrich WSE among existing sleeves. Verify that the actual housing is securely installed and structurally sound; do not infer identity from a 27-inch measurement alone.Source 11Source 13
  • Use generic-sleeve Method B on printed page 16, with the specified dual-intake grille, sealing and centering materials and grounding wire. Remove the old rear grille. Optional Method A and architectural louver UXAA on page 15 are specified for USC, not this WSE procedure.Source 13
  • The manual describes a provided installation kit. Confirm that the exact unit package includes the required grille and seals; obtain manufacturer confirmation of replacement part numbers if these pieces are missing. No separate kit SKU is established in this record.Source 13Source 108
  • Use the included decorative trim ring to cover the gap around the smaller chassis. Follow the prescribed sealing and 3/8-inch downward slope from front to back; use the manual’s shimming procedure if needed.Source 11Source 13
  • Check the installation for the exact 115 V model, NEMA 5-15P plug, NEMA 5-15R receptacle and manufacturer-specified 15 A circuit/fuse. Do not derive the circuit from cooling running current.Source 10Source 14
GE AKCQ08AXXXA2025/2026 inverter generation; exact full SKU covered by 49-5001293Availability not checked
  • Specified circuit/fuse comparison not documented or disputed.
  • 2.5% less published cooling capacity than the old unit; reassess the room requirements.
Kit included — install as specifiedSleeve: Friedrich WSESource 2Source 527,800 BTU/hSource 92115 VSource 92PlugNEMA 5-15PSource 92ReceptacleNEMA 5-15RSource 52Source 92Source 119Specified circuit / fuseNot documented
  • Supplied rear louvered panel, supports, seals and ground wirePart number: Not documentedRequired under the listed conditionsSource 52Package: Included in the unit package — install as specified
3 installation checks
  • For an existing, sound Friedrich WSE matching the 27 × 16-3/4 × 16-3/4 in Friedrich housing in the AC installation manual. Confirm the sleeve label, dimensions and condition.Source 2Source 52
  • Follow the GE instructions for a 16-3/4 in deep Friedrich sleeve, including replacement of the rear grille with the supplied louvered panel and the specified supports, seals and grounding.Source 52
  • Verify the exact AC nameplate, grounded outlet, circuit and room size before purchase.Source 52
Friedrich UCT10B10AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checked
  • 25.0% more published cooling capacity than the old unit; reassess the room requirements.
Kit included — install as specifiedSleeve: Friedrich WSESource 10Source 11Source 13Source 14Source 10810,000 BTU/hSource 9115 VSource 9PlugNEMA 5-15PSource 10ReceptacleNEMA 5-15RSource 14Specified circuit / fuse15 ASource 10
  • Provided Uni-Fit installation kit: specified dual-intake grille, seals and centering/grounding materials; confirm package contentsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
  • Included decorative trim ringPart number: Not documentedRequired under the listed conditionsSource 11Source 108Package: Included in the unit package — install as specified
5 installation checks
  • The current brochure and the exact-generation R-32 manual name Friedrich WSE among existing sleeves. Verify that the actual housing is securely installed and structurally sound; do not infer identity from a 27-inch measurement alone.Source 11Source 13
  • Use generic-sleeve Method B on printed page 16, with the specified dual-intake grille, sealing and centering materials and grounding wire. Remove the old rear grille. Optional Method A and architectural louver UXAA on page 15 are specified for USC, not this WSE procedure.Source 13
  • The manual describes a provided installation kit. Confirm that the exact unit package includes the required grille and seals; obtain manufacturer confirmation of replacement part numbers if these pieces are missing. No separate kit SKU is established in this record.Source 13Source 108
  • Use the included decorative trim ring to cover the gap around the smaller chassis. Follow the prescribed sealing and 3/8-inch downward slope from front to back; use the manual’s shimming procedure if needed.Source 11Source 13
  • Check the installation for the exact 115 V model, NEMA 5-15P plug, NEMA 5-15R receptacle and manufacturer-specified 15 A circuit/fuse. Do not derive the circuit from cooling running current.Source 10Source 14
Friedrich UCT10B30AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checked
  • Nominal voltage differs: old 115 V; replacement 230 V.
  • Plug differs: old NEMA 5-15P; replacement NEMA 6-15P.
  • 25.0% more published cooling capacity than the old unit; reassess the room requirements.
Kit included — install as specifiedSleeve: Friedrich WSESource 10Source 11Source 13Source 14Source 10810,000 BTU/hSource 9230 VSource 9PlugNEMA 6-15PSource 10ReceptacleNEMA 6-15RSource 14Specified circuit / fuse15 ASource 10
  • Provided Uni-Fit installation kit: specified dual-intake grille, seals and centering/grounding materials; confirm package contentsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
  • Included decorative trim ringPart number: Not documentedRequired under the listed conditionsSource 11Source 108Package: Included in the unit package — install as specified
5 installation checks
  • The current brochure and the exact-generation R-32 manual name Friedrich WSE among existing sleeves. Verify that the actual housing is securely installed and structurally sound; do not infer identity from a 27-inch measurement alone.Source 11Source 13
  • Use generic-sleeve Method B on printed page 16, with the specified dual-intake grille, sealing and centering materials and grounding wire. Remove the old rear grille. Optional Method A and architectural louver UXAA on page 15 are specified for USC, not this WSE procedure.Source 13
  • The manual describes a provided installation kit. Confirm that the exact unit package includes the required grille and seals; obtain manufacturer confirmation of replacement part numbers if these pieces are missing. No separate kit SKU is established in this record.Source 13Source 108
  • Use the included decorative trim ring to cover the gap around the smaller chassis. Follow the prescribed sealing and 3/8-inch downward slope from front to back; use the manual’s shimming procedure if needed.Source 11Source 13
  • Check the installation for the exact 230 V model, NEMA 6-15P plug, NEMA 6-15R receptacle and manufacturer-specified 15 A circuit/fuse. Do not derive the circuit from cooling running current.Source 10Source 14
Friedrich UET10B33AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checked
  • Nominal voltage differs: old 115 V; replacement 230 V.
  • Plug differs: old NEMA 5-15P; replacement NEMA 6-20P.
  • Specified circuit/fuse differs: old 15 A; replacement 20 A.
  • Heating type differs: old Cooling only; replacement Electric heat.
  • 25.0% more published cooling capacity than the old unit; reassess the room requirements.
Kit included — install as specifiedSleeve: Friedrich WSESource 10Source 11Source 13Source 14Source 10810,000 BTU/hSource 9230 VSource 9PlugNEMA 6-20PSource 10ReceptacleNEMA 6-20RSource 14Specified circuit / fuse20 ASource 10
  • Provided Uni-Fit installation kit: specified dual-intake grille, seals and centering/grounding materials; confirm package contentsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
  • Included decorative trim ringPart number: Not documentedRequired under the listed conditionsSource 11Source 108Package: Included in the unit package — install as specified
5 installation checks
  • The current brochure and the exact-generation R-32 manual name Friedrich WSE among existing sleeves. Verify that the actual housing is securely installed and structurally sound; do not infer identity from a 27-inch measurement alone.Source 11Source 13
  • Use generic-sleeve Method B on printed page 16, with the specified dual-intake grille, sealing and centering materials and grounding wire. Remove the old rear grille. Optional Method A and architectural louver UXAA on page 15 are specified for USC, not this WSE procedure.Source 13
  • The manual describes a provided installation kit. Confirm that the exact unit package includes the required grille and seals; obtain manufacturer confirmation of replacement part numbers if these pieces are missing. No separate kit SKU is established in this record.Source 13Source 108
  • Use the included decorative trim ring to cover the gap around the smaller chassis. Follow the prescribed sealing and 3/8-inch downward slope from front to back; use the manual’s shimming procedure if needed.Source 11Source 13
  • Check the installation for the exact 230 V model, NEMA 6-20P plug, NEMA 6-20R receptacle and manufacturer-specified 20 A circuit/fuse. Do not derive the circuit from cooling running current.Source 10Source 14
Friedrich UCT12B10AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checked
  • 50.0% more published cooling capacity than the old unit; reassess the room requirements.
Kit included — install as specifiedSleeve: Friedrich WSESource 10Source 11Source 13Source 14Source 10812,000 BTU/hSource 9115 VSource 9PlugNEMA 5-15PSource 10ReceptacleNEMA 5-15RSource 14Specified circuit / fuse15 ASource 10
  • Provided Uni-Fit installation kit: specified dual-intake grille, seals and centering/grounding materials; confirm package contentsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
  • Included decorative trim ringPart number: Not documentedRequired under the listed conditionsSource 11Source 108Package: Included in the unit package — install as specified
5 installation checks
  • The current brochure and the exact-generation R-32 manual name Friedrich WSE among existing sleeves. Verify that the actual housing is securely installed and structurally sound; do not infer identity from a 27-inch measurement alone.Source 11Source 13
  • Use generic-sleeve Method B on printed page 16, with the specified dual-intake grille, sealing and centering materials and grounding wire. Remove the old rear grille. Optional Method A and architectural louver UXAA on page 15 are specified for USC, not this WSE procedure.Source 13
  • The manual describes a provided installation kit. Confirm that the exact unit package includes the required grille and seals; obtain manufacturer confirmation of replacement part numbers if these pieces are missing. No separate kit SKU is established in this record.Source 13Source 108
  • Use the included decorative trim ring to cover the gap around the smaller chassis. Follow the prescribed sealing and 3/8-inch downward slope from front to back; use the manual’s shimming procedure if needed.Source 11Source 13
  • Check the installation for the exact 115 V model, NEMA 5-15P plug, NEMA 5-15R receptacle and manufacturer-specified 15 A circuit/fuse. Do not derive the circuit from cooling running current.Source 10Source 14
Friedrich UCT12B30AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checked
  • Nominal voltage differs: old 115 V; replacement 230 V.
  • Plug differs: old NEMA 5-15P; replacement NEMA 6-15P.
  • 50.0% more published cooling capacity than the old unit; reassess the room requirements.
Kit included — install as specifiedSleeve: Friedrich WSESource 10Source 11Source 13Source 14Source 10812,000 BTU/hSource 9230 VSource 9PlugNEMA 6-15PSource 10ReceptacleNEMA 6-15RSource 14Specified circuit / fuse15 ASource 10
  • Provided Uni-Fit installation kit: specified dual-intake grille, seals and centering/grounding materials; confirm package contentsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
  • Included decorative trim ringPart number: Not documentedRequired under the listed conditionsSource 11Source 108Package: Included in the unit package — install as specified
5 installation checks
  • The current brochure and the exact-generation R-32 manual name Friedrich WSE among existing sleeves. Verify that the actual housing is securely installed and structurally sound; do not infer identity from a 27-inch measurement alone.Source 11Source 13
  • Use generic-sleeve Method B on printed page 16, with the specified dual-intake grille, sealing and centering materials and grounding wire. Remove the old rear grille. Optional Method A and architectural louver UXAA on page 15 are specified for USC, not this WSE procedure.Source 13
  • The manual describes a provided installation kit. Confirm that the exact unit package includes the required grille and seals; obtain manufacturer confirmation of replacement part numbers if these pieces are missing. No separate kit SKU is established in this record.Source 13Source 108
  • Use the included decorative trim ring to cover the gap around the smaller chassis. Follow the prescribed sealing and 3/8-inch downward slope from front to back; use the manual’s shimming procedure if needed.Source 11Source 13
  • Check the installation for the exact 230 V model, NEMA 6-15P plug, NEMA 6-15R receptacle and manufacturer-specified 15 A circuit/fuse. Do not derive the circuit from cooling running current.Source 10Source 14
Friedrich UET12B33AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checked
  • Nominal voltage differs: old 115 V; replacement 230 V.
  • Plug differs: old NEMA 5-15P; replacement NEMA 6-20P.
  • Specified circuit/fuse differs: old 15 A; replacement 20 A.
  • Heating type differs: old Cooling only; replacement Electric heat.
  • 50.0% more published cooling capacity than the old unit; reassess the room requirements.
Kit included — install as specifiedSleeve: Friedrich WSESource 10Source 11Source 13Source 14Source 10812,000 BTU/hSource 9230 VSource 9PlugNEMA 6-20PSource 10ReceptacleNEMA 6-20RSource 14Specified circuit / fuse20 ASource 10
  • Provided Uni-Fit installation kit: specified dual-intake grille, seals and centering/grounding materials; confirm package contentsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
  • Included decorative trim ringPart number: Not documentedRequired under the listed conditionsSource 11Source 108Package: Included in the unit package — install as specified
5 installation checks
  • The current brochure and the exact-generation R-32 manual name Friedrich WSE among existing sleeves. Verify that the actual housing is securely installed and structurally sound; do not infer identity from a 27-inch measurement alone.Source 11Source 13
  • Use generic-sleeve Method B on printed page 16, with the specified dual-intake grille, sealing and centering materials and grounding wire. Remove the old rear grille. Optional Method A and architectural louver UXAA on page 15 are specified for USC, not this WSE procedure.Source 13
  • The manual describes a provided installation kit. Confirm that the exact unit package includes the required grille and seals; obtain manufacturer confirmation of replacement part numbers if these pieces are missing. No separate kit SKU is established in this record.Source 13Source 108
  • Use the included decorative trim ring to cover the gap around the smaller chassis. Follow the prescribed sealing and 3/8-inch downward slope from front to back; use the manual’s shimming procedure if needed.Source 11Source 13
  • Check the installation for the exact 230 V model, NEMA 6-20P plug, NEMA 6-20R receptacle and manufacturer-specified 20 A circuit/fuse. Do not derive the circuit from cooling running current.Source 10Source 14
Friedrich UCT14B30AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checked
  • Nominal voltage differs: old 115 V; replacement 230 V.
  • Plug differs: old NEMA 5-15P; replacement NEMA 6-15P.
  • 75.0% more published cooling capacity than the old unit; reassess the room requirements.
Kit included — install as specifiedSleeve: Friedrich WSESource 10Source 11Source 13Source 14Source 10814,000 BTU/hSource 9230 VSource 9PlugNEMA 6-15PSource 10ReceptacleNEMA 6-15RSource 14Specified circuit / fuse15 ASource 10
  • Provided Uni-Fit installation kit: specified dual-intake grille, seals and centering/grounding materials; confirm package contentsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
  • Included decorative trim ringPart number: Not documentedRequired under the listed conditionsSource 11Source 108Package: Included in the unit package — install as specified
5 installation checks
  • The current brochure and the exact-generation R-32 manual name Friedrich WSE among existing sleeves. Verify that the actual housing is securely installed and structurally sound; do not infer identity from a 27-inch measurement alone.Source 11Source 13
  • Use generic-sleeve Method B on printed page 16, with the specified dual-intake grille, sealing and centering materials and grounding wire. Remove the old rear grille. Optional Method A and architectural louver UXAA on page 15 are specified for USC, not this WSE procedure.Source 13
  • The manual describes a provided installation kit. Confirm that the exact unit package includes the required grille and seals; obtain manufacturer confirmation of replacement part numbers if these pieces are missing. No separate kit SKU is established in this record.Source 13Source 108
  • Use the included decorative trim ring to cover the gap around the smaller chassis. Follow the prescribed sealing and 3/8-inch downward slope from front to back; use the manual’s shimming procedure if needed.Source 11Source 13
  • Check the installation for the exact 230 V model, NEMA 6-15P plug, NEMA 6-15R receptacle and manufacturer-specified 15 A circuit/fuse. Do not derive the circuit from cooling running current.Source 10Source 14
Friedrich UET14B33AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checked
  • Nominal voltage differs: old 115 V; replacement 230 V.
  • Plug differs: old NEMA 5-15P; replacement NEMA 6-20P.
  • Specified circuit/fuse differs: old 15 A; replacement 20 A.
  • Heating type differs: old Cooling only; replacement Electric heat.
  • 75.0% more published cooling capacity than the old unit; reassess the room requirements.
Kit included — install as specifiedSleeve: Friedrich WSESource 10Source 11Source 13Source 14Source 10814,000 BTU/hSource 9230 VSource 9PlugNEMA 6-20PSource 10ReceptacleNEMA 6-20RSource 14Specified circuit / fuse20 ASource 10
  • Provided Uni-Fit installation kit: specified dual-intake grille, seals and centering/grounding materials; confirm package contentsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
  • Included decorative trim ringPart number: Not documentedRequired under the listed conditionsSource 11Source 108Package: Included in the unit package — install as specified
5 installation checks
  • The current brochure and the exact-generation R-32 manual name Friedrich WSE among existing sleeves. Verify that the actual housing is securely installed and structurally sound; do not infer identity from a 27-inch measurement alone.Source 11Source 13
  • Use generic-sleeve Method B on printed page 16, with the specified dual-intake grille, sealing and centering materials and grounding wire. Remove the old rear grille. Optional Method A and architectural louver UXAA on page 15 are specified for USC, not this WSE procedure.Source 13
  • The manual describes a provided installation kit. Confirm that the exact unit package includes the required grille and seals; obtain manufacturer confirmation of replacement part numbers if these pieces are missing. No separate kit SKU is established in this record.Source 13Source 108
  • Use the included decorative trim ring to cover the gap around the smaller chassis. Follow the prescribed sealing and 3/8-inch downward slope from front to back; use the manual’s shimming procedure if needed.Source 11Source 13
  • Check the installation for the exact 230 V model, NEMA 6-20P plug, NEMA 6-20R receptacle and manufacturer-specified 20 A circuit/fuse. Do not derive the circuit from cooling running current.Source 10Source 14

Before you buy

  • Confirm the actual sleeve. Confirm WSE on the sleeve documentation or label. The assembled WSE and the knock-down WSEZ are separately named products; this record covers WSE.Source 4The brochure lists the WSE housing as 27 in wide × 16.75 in high × 16.75 in deep. These are sleeve dimensions, not a measured internal clearance or proof of compatibility.Source 2WSE is sold with an expanded-metal grille for WallMaster installations. The reviewed Uni-Fit replacement procedure instead requires its specified dual-intake grille; follow the model-specific relationship below rather than retaining the old grille.Source 4Source 13
  • Check the electrical requirements. Compare the full model's voltage, plug/receptacle and specified circuit or fuse with the actual installation. Rated running current alone does not specify the circuit.
  • Check the rear grille and parts. Use the listed part numbers and installation conditions; similar dimensions alone do not establish fit.
  • Reassess cooling and heating needs. The old unit’s capacity is a starting point for comparison. A suitable replacement capacity depends on the room and its current requirements.

Sources and review

Reviewed 2026-11-22. Sources include document locations and dates checked.