← Wall sleeves

IDENTIFY YOUR EXISTING SLEEVE

What fits the Friedrich USC sleeve?

Manufacturer-documented USC sleeve for the reviewed R-32 Uni-Fit models. New installations require a separately purchased sleeve; use the exact manual and supplied installation parts.

10 documented options. 10 with required kit included.

Confirm this is your actual sleeve. Each option has separate installation and electrical requirements.

How to identify it

  • Confirm the exact USC part number; dimensions alone do not establish compatibility.Source 99

Dimensions: three different measurements

Interior dimensions, outside sleeve dimensions and the wall opening are different. These values describe the equipment; they do not prove fit.

Interior width
Not documented
Interior height
Not documented
Interior depth
Not documented
External width
25.875 inSource 99
External height
15.5 inSource 99
External depth
16.75 inSource 99
Wall opening width
26.125 inSource 99
Wall opening height
15.75 inSource 99

Replacement options

Replacement options and documented installation requirements
ModelFit statusCoolingElectrical requirementsRequired / conditional partsWhat to check
Friedrich UCT08B10AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checkedKit included — install as specifiedSleeve: Friedrich USCSource 13Source 14Source 99Source 1088,000 BTU/hSource 9115 VSource 9PlugNEMA 5-15PSource 10ReceptacleNEMA 5-15RSource 14Specified circuit / fuse15 ASource 10
  • Decorative trim ring supplied with chassisPart number: Not documentedRequired under the listed conditionsSource 99Source 108Package: Included in the unit package — install as specified
  • Provided installation kit: specified grille, seals and centering/grounding materialsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
3 installation checks
  • The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.Source 99
  • Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.Source 13
  • Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.Source 14
Friedrich UCT10B10AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checkedKit included — install as specifiedSleeve: Friedrich USCSource 13Source 14Source 99Source 10810,000 BTU/hSource 9115 VSource 9PlugNEMA 5-15PSource 10ReceptacleNEMA 5-15RSource 14Specified circuit / fuse15 ASource 10
  • Decorative trim ring supplied with chassisPart number: Not documentedRequired under the listed conditionsSource 99Source 108Package: Included in the unit package — install as specified
  • Provided installation kit: specified grille, seals and centering/grounding materialsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
3 installation checks
  • The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.Source 99
  • Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.Source 13
  • Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.Source 14
Friedrich UCT10B30AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checkedKit included — install as specifiedSleeve: Friedrich USCSource 13Source 14Source 99Source 10810,000 BTU/hSource 9230 VSource 9PlugNEMA 6-15PSource 10ReceptacleNEMA 6-15RSource 14Specified circuit / fuse15 ASource 10
  • Decorative trim ring supplied with chassisPart number: Not documentedRequired under the listed conditionsSource 99Source 108Package: Included in the unit package — install as specified
  • Provided installation kit: specified grille, seals and centering/grounding materialsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
3 installation checks
  • The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.Source 99
  • Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.Source 13
  • Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.Source 14
Friedrich UCT12B10AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checkedKit included — install as specifiedSleeve: Friedrich USCSource 13Source 14Source 99Source 10812,000 BTU/hSource 9115 VSource 9PlugNEMA 5-15PSource 10ReceptacleNEMA 5-15RSource 14Specified circuit / fuse15 ASource 10
  • Decorative trim ring supplied with chassisPart number: Not documentedRequired under the listed conditionsSource 99Source 108Package: Included in the unit package — install as specified
  • Provided installation kit: specified grille, seals and centering/grounding materialsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
3 installation checks
  • The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.Source 99
  • Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.Source 13
  • Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.Source 14
Friedrich UCT12B30AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checkedKit included — install as specifiedSleeve: Friedrich USCSource 13Source 14Source 99Source 10812,000 BTU/hSource 9230 VSource 9PlugNEMA 6-15PSource 10ReceptacleNEMA 6-15RSource 14Specified circuit / fuse15 ASource 10
  • Decorative trim ring supplied with chassisPart number: Not documentedRequired under the listed conditionsSource 99Source 108Package: Included in the unit package — install as specified
  • Provided installation kit: specified grille, seals and centering/grounding materialsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
3 installation checks
  • The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.Source 99
  • Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.Source 13
  • Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.Source 14
Friedrich UCT14B30AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checkedKit included — install as specifiedSleeve: Friedrich USCSource 13Source 14Source 99Source 10814,000 BTU/hSource 9230 VSource 9PlugNEMA 6-15PSource 10ReceptacleNEMA 6-15RSource 14Specified circuit / fuse15 ASource 10
  • Decorative trim ring supplied with chassisPart number: Not documentedRequired under the listed conditionsSource 99Source 108Package: Included in the unit package — install as specified
  • Provided installation kit: specified grille, seals and centering/grounding materialsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
3 installation checks
  • The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.Source 99
  • Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.Source 13
  • Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.Source 14
Friedrich UET08B11AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checkedKit included — install as specifiedSleeve: Friedrich USCSource 13Source 14Source 99Source 1088,000 BTU/hSource 9115 VSource 9PlugNEMA 5-15PSource 10ReceptacleNEMA 5-15RSource 14Specified circuit / fuse15 ASource 10
  • Decorative trim ring supplied with chassisPart number: Not documentedRequired under the listed conditionsSource 99Source 108Package: Included in the unit package — install as specified
  • Provided installation kit: specified grille, seals and centering/grounding materialsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
3 installation checks
  • The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.Source 99
  • Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.Source 13
  • Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.Source 14
Friedrich UET10B33AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checkedKit included — install as specifiedSleeve: Friedrich USCSource 13Source 14Source 99Source 10810,000 BTU/hSource 9230 VSource 9PlugNEMA 6-20PSource 10ReceptacleNEMA 6-20RSource 14Specified circuit / fuse20 ASource 10
  • Decorative trim ring supplied with chassisPart number: Not documentedRequired under the listed conditionsSource 99Source 108Package: Included in the unit package — install as specified
  • Provided installation kit: specified grille, seals and centering/grounding materialsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
3 installation checks
  • The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.Source 99
  • Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.Source 13
  • Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.Source 14
Friedrich UET12B33AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checkedKit included — install as specifiedSleeve: Friedrich USCSource 13Source 14Source 99Source 10812,000 BTU/hSource 9230 VSource 9PlugNEMA 6-20PSource 10ReceptacleNEMA 6-20RSource 14Specified circuit / fuse20 ASource 10
  • Decorative trim ring supplied with chassisPart number: Not documentedRequired under the listed conditionsSource 99Source 108Package: Included in the unit package — install as specified
  • Provided installation kit: specified grille, seals and centering/grounding materialsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
3 installation checks
  • The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.Source 99
  • Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.Source 13
  • Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.Source 14
Friedrich UET14B33AUCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25Availability not checkedKit included — install as specifiedSleeve: Friedrich USCSource 13Source 14Source 99Source 10814,000 BTU/hSource 9230 VSource 9PlugNEMA 6-20PSource 10ReceptacleNEMA 6-20RSource 14Specified circuit / fuse20 ASource 10
  • Decorative trim ring supplied with chassisPart number: Not documentedRequired under the listed conditionsSource 99Source 108Package: Included in the unit package — install as specified
  • Provided installation kit: specified grille, seals and centering/grounding materialsPart number: Not documentedRequired under the listed conditionsSource 13Source 108Package: Included in the unit package — install as specified
3 installation checks
  • The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.Source 99
  • Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.Source 13
  • Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.Source 14

Old models documented for this sleeve

No old-model associations have been published yet.

Sources and review

Reviewed 2026-10-13.