Unknown or disputed facts remain visible in each profile. These are candidates for verification, not installation approvals.
More checks neededFriedrich
- Nominal supply
- 115 V
- Nominal cooling rating
- 8,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.1
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT08B10A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 115 V
- Nominal cooling rating
- 10,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.1
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT10B10A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 230 V
- Nominal cooling rating
- 10,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 6-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.1
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT10B30A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 115 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT12B10A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 6-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT12B30A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 230 V
- Nominal cooling rating
- 14,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 6-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 9.3
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT14B30A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 115 V
- Nominal cooling rating
- 8,000 BTU/h
- Heating
- Electric heat
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 9.6
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UET08B11A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 230 V
- Nominal cooling rating
- 10,000 BTU/h
- Heating
- Electric heat
- Plug
- NEMA 6-20P
- Specified circuit / fuse
- 20 A
- CEER (nominal rating)
- 9.6
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UET10B33A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Electric heat
- Plug
- NEMA 6-20P
- Specified circuit / fuse
- 20 A
- CEER (nominal rating)
- 9.6
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UET12B33A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 230 V
- Nominal cooling rating
- 14,000 BTU/h
- Heating
- Electric heat
- Plug
- NEMA 6-20P
- Specified circuit / fuse
- 20 A
- CEER (nominal rating)
- 9.3
Wi-Fi documented
Installation: Friedrich USC · required kit included
Kit inclusion refers to the listed installation parts. Confirm sleeve supply separately.
What matches (1)
- Documented sleeve option: Friedrich USC. Installation conditions apply.
Checks before purchase (5)
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UET14B33A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
Friedrich USC
Manufacturer sleeve association; listed conditions apply.
Decorative trim ring supplied with chassis · Required for the listed procedure · Included as reported in source
Provided installation kit: specified grille, seals and centering/grounding materials · Required for the listed procedure · Included as reported in source
- The 2026 exact-series brochure requires USC/USEZ for new installations; sleeve is sold separately.
- Follow the recommended USC procedure on printed pages 14–15: use the specified dual-intake grille, seals, centering materials and grounding wire. Remove weather panels before operation. Maintain the prescribed 3/8-inch downward slope from front to back. Optional architectural louver UXAA is sold separately and is not the supplied kit SKU.
- Match actual unit nameplate and grounded supply to the electrical table; capacity must also suit the room.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗