Unknown or disputed facts remain visible in each profile. These are candidates for verification, not installation approvals.
More checks neededGE
- Nominal supply
- 115 V
- Nominal cooling rating
- 7,800 BTU/h
- Heating
- Cooling only
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 10.6
Inverter documentedWi-Fi documented
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
- GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
- GE AJCQ08AXXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AJCQ08AXXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- GE projected Quick Specs — AJCQ08AXXWA, AJCQ12AXXWA ↗Single-page exact-model sheet: drawing, CEER and plug/circuit rows; explicitly marked Projected specifications — subject to change. Not final electrical evidence. · Checked 2026-10-12
2025/2026 inverter generation; exact full SKU covered by 49-5001195
Manufacturer specifications ↗More checks neededGE
- Nominal supply
- 115 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 10.5
Inverter documentedWi-Fi documented
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
- GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
- GE AJCQ12AXXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AJCQ12AXXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- GE projected Quick Specs — AJCQ08AXXWA, AJCQ12AXXWA ↗Single-page exact-model sheet: drawing, CEER and plug/circuit rows; explicitly marked Projected specifications — subject to change. Not final electrical evidence. · Checked 2026-10-12
- GE AJCQ12AXXWA — conflicting FEATURES EER ↗Specs & Details > FEATURES > EER: 10.6. CAPACITY > Cooling EER in the same page reports 10.5. These are two section citations, not independent documents. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001195
Manufacturer specifications ↗More checks neededGE
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 10.5
Inverter documentedWi-Fi documented
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
- GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
- GE AJCQ12DXXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AJCQ12DXXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- GE projected Quick Specs — AJCQ12DXXWA ↗Single-page exact-model sheet: drawing, CEER and plug/circuit rows; explicitly marked Projected specifications — subject to change. Not final electrical evidence. · Checked 2026-10-12
2025/2026 inverter generation; exact full SKU covered by 49-5001195
Manufacturer specifications ↗More checks neededGE
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Electric heat
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.5
Inverter documentedWi-Fi documented
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
- GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
- GE AJEQ12DCXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AJEQ12DCXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- GE projected Quick Specs — AJEQ12DCXWA ↗Single-page exact-model sheet: drawing, CEER and plug/circuit rows; explicitly marked Projected specifications — subject to change. Not final electrical evidence. · Checked 2026-10-12
2025/2026 inverter generation; exact full SKU covered by 49-5001195
Manufacturer specifications ↗More checks neededGE
- Nominal supply
- 115 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Heat pump with electric backup
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.6
Inverter documentedWi-Fi documented
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
- GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
- GE AJVQ12ACXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AJVQ12ACXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001195
Manufacturer specifications ↗More checks neededGE
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Heat pump with electric backup
- Plug
- Not established
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.5
Inverter documentedWi-Fi documented
Verify circuit rating, plug, outletWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Exact plug configuration is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
- Required receptacle is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
- GE 26-inch inverter owner and installation manual ↗Cover lists all six exact AJ models and INVERTER. Printed/PDF pages 15–16: RAB26A/RAB46B with RAG13A, depth without front, supplied security bracket, grille and heat-model clearance requirements. No numeric branch-circuit requirement in the final English manual. · Checked 2026-10-13
- GE AJVQ12DCXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AJVQ12DCXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001195
Manufacturer specifications ↗More checks neededGE
- Nominal supply
- 115 V
- Nominal cooling rating
- 7,800 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.6
Inverter documented
Verify circuit ratingWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
- GE 24-inch inverter owner and installation manual ↗Cover lists all four exact AK models and INVERTER. Printed/PDF pages 15–19 and 23–24: bare chassis, RAB24/RAB26A, supplied hardware, rearward slope, grounding, GE rear grille, trim and correct 24/26-inch security brackets. RAB26A recommendation spells RAG13 (not RAG13A). No numeric branch-circuit requirement. · Checked 2026-10-13
- GE AKCQ08AXXXA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AKCQ08AXXXA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
- GE AKCQ08AXXXA — conflicting FEATURES EER ↗Specs & Details > FEATURES > EER: 9.6. CAPACITY > Cooling EER in the same page reports 10.6. These are two section citations, not independent documents. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001293
Manufacturer specifications ↗More checks neededGE
- Nominal supply
- 115 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.5
Inverter documented
Verify circuit ratingWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
- GE 24-inch inverter owner and installation manual ↗Cover lists all four exact AK models and INVERTER. Printed/PDF pages 15–19 and 23–24: bare chassis, RAB24/RAB26A, supplied hardware, rearward slope, grounding, GE rear grille, trim and correct 24/26-inch security brackets. RAB26A recommendation spells RAG13 (not RAG13A). No numeric branch-circuit requirement. · Checked 2026-10-13
- GE AKCQ12AXXXA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AKCQ12AXXXA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
- GE AKCQ12AXXXA — conflicting FEATURES EER ↗Specs & Details > FEATURES > EER: 9.5. CAPACITY > Cooling EER in the same page reports 10.5. These are two section citations, not independent documents. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001293
Manufacturer specifications ↗More checks neededGE
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 6-15P
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.5
Inverter documented
Verify circuit ratingWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
- GE 24-inch inverter owner and installation manual ↗Cover lists all four exact AK models and INVERTER. Printed/PDF pages 15–19 and 23–24: bare chassis, RAB24/RAB26A, supplied hardware, rearward slope, grounding, GE rear grille, trim and correct 24/26-inch security brackets. RAB26A recommendation spells RAG13 (not RAG13A). No numeric branch-circuit requirement. · Checked 2026-10-13
- GE AKCQ12DXXXA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AKCQ12DXXXA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
- GE AKCQ12DXXXA — conflicting FEATURES EER ↗Specs & Details > FEATURES > EER: 9.5. CAPACITY > Cooling EER in the same page reports 10.5. These are two section citations, not independent documents. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001293
Manufacturer specifications ↗More checks neededGE
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Heat pump with electric backup
- Plug
- NEMA 6-20P
- Specified circuit / fuse
- Not established
- CEER (nominal rating)
- 9.5
Inverter documentedWi-Fi documented
Verify circuit ratingWhy these facts need checking
- Required circuit / fuse rating is not established in the reviewed documentation. Check the exact unit nameplate or ask GE to confirm it before purchase.
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- The manufacturer circuit/fuse rating is not established. Check the exact unit nameplate or ask GE to confirm it before purchase; your circuit answer cannot fill this gap.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
- GE 24-inch inverter owner and installation manual ↗Cover lists all four exact AK models and INVERTER. Printed/PDF pages 15–19 and 23–24: bare chassis, RAB24/RAB26A, supplied hardware, rearward slope, grounding, GE rear grille, trim and correct 24/26-inch security brackets. RAB26A recommendation spells RAG13 (not RAG13A). No numeric branch-circuit requirement. · Checked 2026-10-13
- GE AKVQ12DXXWA — manufacturing dates ↗Owner Center > Manufactured start/end dates; a fixed past end date indicates discontinued production, not lack of retailer stock. · Checked 2026-10-13
- GE AKVQ12DXXWA — exact product specifications ↗Specs & Details: POWER / RATINGS, FEATURES, ACCESSORIES, WEIGHTS & DIMENSIONS; only product specification fields retained. Hidden obsolete/out-of-stock template strings are not lifecycle/stock evidence. · Checked 2026-10-13
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
2025/2026 inverter generation; exact full SKU covered by 49-5001293
Manufacturer specifications ↗More checks neededLG
- Nominal supply
- 115 V
- Nominal cooling rating
- 8,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.6
Reported indoor noise: 56 dBA (Manufacturer rating; fan speed and test conditions not stated). Test conditions vary by source.
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
- LG US wall air conditioner category ↗Eleven LT equipment entries observed in initial category HTML; accessories excluded. Dynamic pagination is not proof of complete coverage. · Checked 2026-10-12
- LG owner manual — cool ↗Support associations checked 2026-10-12; visually reviewed 2026-10-13. Printed/PDF page 9 explicitly lists LT0816CER, LT1016CER, LT12124CNR (115 V) and LT1036CER, LT1236CER, LT1430CNR (230 V), 15 A circuit and outlet drawings; pages 11–13 packing list and LGE sleeve Procedure A. LT1216CER has a separate exact support manual. · Checked 2026-10-13
- LG LT0816CER — current product specifications ↗Specifications > Electrical Ratings, Performance, Features and Dimensions/Weight; public page specification data; product modelStatus ACTIVE checked separately from stock. · Checked 2026-10-13
- LG LT0816CER — exact support/document association ↗Selected support sales suffix and Download Manuals list; suffix is not automatically an alias of another physical generation. · Checked 2026-10-12
- LG LT0816CER — linked specification sheet ↗Exact SKU specifications, refrigerant and Optional Accessories. Dates differ across PDFs; older electrical/performance tables are not merged into current page values. · Checked 2026-10-12
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
Reviewed marketed SKU and UPC 048231379601; selected support LT0816CER.AT1AUSB. Base model is not an alias of every historical sales suffix.
Manufacturer specifications ↗More checks neededLG
- Nominal supply
- 115 V
- Nominal cooling rating
- 9,800 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.6
Reported indoor noise: 56 dBA (Manufacturer rating; fan speed and test conditions not stated). Test conditions vary by source.
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
- LG US wall air conditioner category ↗Eleven LT equipment entries observed in initial category HTML; accessories excluded. Dynamic pagination is not proof of complete coverage. · Checked 2026-10-12
- LG owner manual — cool ↗Support associations checked 2026-10-12; visually reviewed 2026-10-13. Printed/PDF page 9 explicitly lists LT0816CER, LT1016CER, LT12124CNR (115 V) and LT1036CER, LT1236CER, LT1430CNR (230 V), 15 A circuit and outlet drawings; pages 11–13 packing list and LGE sleeve Procedure A. LT1216CER has a separate exact support manual. · Checked 2026-10-13
- LG LT1016CER — current product specifications ↗Specifications > Electrical Ratings, Performance, Features and Dimensions/Weight; public page specification data; product modelStatus ACTIVE checked separately from stock. · Checked 2026-10-13
- LG LT1016CER — exact support/document association ↗Selected support sales suffix and Download Manuals list; suffix is not automatically an alias of another physical generation. · Checked 2026-10-12
- LG LT1016CER — linked specification sheet ↗Exact SKU specifications, refrigerant and Optional Accessories. Dates differ across PDFs; older electrical/performance tables are not merged into current page values. · Checked 2026-10-12
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
Reviewed marketed SKU and UPC 048231379618; selected support LT1016CER.AT1AUSL. Base model is not an alias of every historical sales suffix.
Manufacturer specifications ↗More checks neededLG
- Nominal supply
- 230 V
- Nominal cooling rating
- 10,000 BTU/h
- Heating
- Electric heat
- Plug
- Not established
- Specified circuit / fuse
- 20 A
- CEER (nominal rating)
- 10.7
Verify plugWhy these facts need checking
- Exact plug configuration is disputed between sources. Ask LG to confirm the exact model version and requirement before purchase.
Checks before purchase (7)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Exact plug configuration is disputed between sources. Ask LG to confirm the exact model version and requirement before purchase.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
- LG US wall air conditioner category ↗Eleven LT equipment entries observed in initial category HTML; accessories excluded. Dynamic pagination is not proof of complete coverage. · Checked 2026-10-12
- LG owner manual — heat ↗Selected LT1033HNR.AT3AUSH / LT1233HNR.AT3AUSH support associations; printed/PDF page 9 circuit/outlet requirements (cord drawing inconsistent); pages 11–13 supplied parts, LGE Procedure A, 40 in combustible-surface clearance. Do not apply to R410A suffixes. · Checked 2026-10-13
- LG LT1033HNR — current product specifications ↗Specifications > Electrical Ratings, Performance, Features and Dimensions/Weight; public page specification data; product modelStatus ACTIVE checked separately from stock. · Checked 2026-10-13
- LG LT1033HNR — exact support/document association ↗Selected support sales suffix and Download Manuals list; suffix is not automatically an alias of another physical generation. · Checked 2026-10-13
- LG LT1033HNR — linked specification sheet ↗Exact SKU specifications, refrigerant and Optional Accessories. Dates differ across PDFs; older electrical/performance tables are not merged into current page values. · Checked 2026-10-12
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
- LG R-32 heat manual — cord drawing ↗Printed/PDF page 9, top 230 V power-cord drawing: two horizontal blades. Conflicts with the perpendicular 20 A receptacle in the table below; actual plug is not established. · Checked 2026-10-13
- LG R-32 heat manual — outlet and circuit table ↗Printed/PDF page 9: perpendicular three-wire grounding receptacle rated 20 A / 250 V and explicit 20 A time-delay fuse/circuit breaker. This table does not settle the inconsistent cord drawing on the same page. · Checked 2026-10-13
Reviewed marketed SKU and UPC 048231606486; selected support LT1033HNR.AT3AUSH. Base model is not an alias of every historical sales suffix.
Manufacturer specifications ↗More checks neededLG
- Nominal supply
- 230 V
- Nominal cooling rating
- 9,800 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 6-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.6
Reported indoor noise: 56 dBA (Manufacturer rating; fan speed and test conditions not stated). Test conditions vary by source.
Verify rated currentWhy these facts need checking
- Rated cooling current is disputed between sources. Ask LG to confirm the exact model version and requirement before purchase.
Checks before purchase (7)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Rated cooling current is disputed between sources. Ask LG to confirm the exact model version and requirement before purchase.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
- LG US wall air conditioner category ↗Eleven LT equipment entries observed in initial category HTML; accessories excluded. Dynamic pagination is not proof of complete coverage. · Checked 2026-10-12
- LG owner manual — cool ↗Support associations checked 2026-10-12; visually reviewed 2026-10-13. Printed/PDF page 9 explicitly lists LT0816CER, LT1016CER, LT12124CNR (115 V) and LT1036CER, LT1236CER, LT1430CNR (230 V), 15 A circuit and outlet drawings; pages 11–13 packing list and LGE sleeve Procedure A. LT1216CER has a separate exact support manual. · Checked 2026-10-13
- LG LT1036CER — current product specifications ↗Specifications > Electrical Ratings, Performance, Features and Dimensions/Weight; public page specification data; product modelStatus ACTIVE checked separately from stock. · Checked 2026-10-13
- LG LT1036CER — exact support/document association ↗Selected support sales suffix and Download Manuals list; suffix is not automatically an alias of another physical generation. · Checked 2026-10-12
- LG LT1036CER — linked specification sheet ↗Exact SKU specifications, refrigerant and Optional Accessories. Dates differ across PDFs; older electrical/performance tables are not merged into current page values. · Checked 2026-10-12
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
Reviewed marketed SKU and UPC 048231379625; selected support LT1036CER.AT3AHDS. Base model is not an alias of every historical sales suffix.
Manufacturer specifications ↗More checks neededLG
- Nominal supply
- 230 V
- Nominal cooling rating
- 10,000 BTU/h
- Heating
- Electric heat
- Plug
- NEMA 6-20P
- Specified circuit / fuse
- 20 A
- CEER (nominal rating)
- 9.7
Reported indoor noise: 56 dBA (Manufacturer rating; fan speed and test conditions not stated). Test conditions vary by source.
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
- LG US wall air conditioner category ↗Eleven LT equipment entries observed in initial category HTML; accessories excluded. Dynamic pagination is not proof of complete coverage. · Checked 2026-10-12
- LG owner manual — oldheat ↗Support-selected LT1037HNR.AC3AUSB / LT1237HNR.ASWAUSH; original download filename explicitly R410A. Visually reviewed printed/PDF page 9: 20 A circuit and consistent perpendicular plug/outlet drawings. Not an R32 manual. · Checked 2026-10-13
- LG LT1037HNR — current product specifications ↗Specifications > Electrical Ratings, Performance, Features and Dimensions/Weight; public page specification data; product modelStatus ACTIVE checked separately from stock. · Checked 2026-10-13
- LG LT1037HNR — exact support/document association ↗Selected support sales suffix and Download Manuals list; suffix is not automatically an alias of another physical generation. · Checked 2026-10-12
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
Reviewed marketed SKU and UPC 048231382274; selected support LT1037HNR.AC3AUSB. Base model is not an alias of every historical sales suffix.
Manufacturer specifications ↗More checks neededLG
- Nominal supply
- 115 V
- Nominal cooling rating
- 11,800 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.5
Reported indoor noise: 60 dBA (Manufacturer rating; fan speed and test conditions not stated). Test conditions vary by source.
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
- LG US wall air conditioner category ↗Eleven LT equipment entries observed in initial category HTML; accessories excluded. Dynamic pagination is not proof of complete coverage. · Checked 2026-10-12
- LG owner manual — cool ↗Support associations checked 2026-10-12; visually reviewed 2026-10-13. Printed/PDF page 9 explicitly lists LT0816CER, LT1016CER, LT12124CNR (115 V) and LT1036CER, LT1236CER, LT1430CNR (230 V), 15 A circuit and outlet drawings; pages 11–13 packing list and LGE sleeve Procedure A. LT1216CER has a separate exact support manual. · Checked 2026-10-13
- LG LT12124CNR — current product specifications ↗Specifications > Electrical Ratings, Performance, Features and Dimensions/Weight; public page specification data; product modelStatus ACTIVE checked separately from stock. · Checked 2026-10-13
- LG LT12124CNR — exact support/document association ↗Selected support sales suffix and Download Manuals list; suffix is not automatically an alias of another physical generation. · Checked 2026-10-12
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
Reviewed marketed SKU and UPC 048231607261; selected support LT12124CNR.AT1AYOW. Base model is not an alias of every historical sales suffix.
Manufacturer specifications ↗More checks neededLG
- Nominal supply
- 115 V
- Nominal cooling rating
- 11,800 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.5
Reported indoor noise: 60 dBA (Manufacturer rating; fan speed and test conditions not stated). Test conditions vary by source.
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
Reviewed marketed SKU and UPC 048231379632; selected support LT1216CER.AT1AHDS. Base model is not an alias of every historical sales suffix.
Manufacturer specifications ↗More checks neededLG
- Nominal supply
- 230 V
- Nominal cooling rating
- 11,800 BTU/h
- Heating
- Electric heat
- Plug
- Not established
- Specified circuit / fuse
- 20 A
- CEER (nominal rating)
- 10.2
Verify plugWhy these facts need checking
- Exact plug configuration is disputed between sources. Ask LG to confirm the exact model version and requirement before purchase.
Checks before purchase (7)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Exact plug configuration is disputed between sources. Ask LG to confirm the exact model version and requirement before purchase.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
- LG US wall air conditioner category ↗Eleven LT equipment entries observed in initial category HTML; accessories excluded. Dynamic pagination is not proof of complete coverage. · Checked 2026-10-12
- LG owner manual — heat ↗Selected LT1033HNR.AT3AUSH / LT1233HNR.AT3AUSH support associations; printed/PDF page 9 circuit/outlet requirements (cord drawing inconsistent); pages 11–13 supplied parts, LGE Procedure A, 40 in combustible-surface clearance. Do not apply to R410A suffixes. · Checked 2026-10-13
- LG LT1233HNR — current product specifications ↗Specifications > Electrical Ratings, Performance, Features and Dimensions/Weight; public page specification data; product modelStatus ACTIVE checked separately from stock. · Checked 2026-10-13
- LG LT1233HNR — exact support/document association ↗Selected support sales suffix and Download Manuals list; suffix is not automatically an alias of another physical generation. · Checked 2026-10-12
- LG LT1233HNR — linked specification sheet ↗Exact SKU specifications, refrigerant and Optional Accessories. Dates differ across PDFs; older electrical/performance tables are not merged into current page values. · Checked 2026-10-12
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
- LG R-32 heat manual — cord drawing ↗Printed/PDF page 9, top 230 V power-cord drawing: two horizontal blades. Conflicts with the perpendicular 20 A receptacle in the table below; actual plug is not established. · Checked 2026-10-13
- LG R-32 heat manual — outlet and circuit table ↗Printed/PDF page 9: perpendicular three-wire grounding receptacle rated 20 A / 250 V and explicit 20 A time-delay fuse/circuit breaker. This table does not settle the inconsistent cord drawing on the same page. · Checked 2026-10-13
Reviewed marketed SKU and UPC 048231606493; selected support LT1233HNR.AT3AUSH. Base model is not an alias of every historical sales suffix.
Manufacturer specifications ↗More checks neededLG
- Nominal supply
- 230 V
- Nominal cooling rating
- 11,800 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 6-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.5
Reported indoor noise: 59 dBA (Manufacturer rating; fan speed and test conditions not stated). Test conditions vary by source.
Verify rated currentWhy these facts need checking
- Rated cooling current is disputed between sources. Ask LG to confirm the exact model version and requirement before purchase.
Checks before purchase (7)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Rated cooling current is disputed between sources. Ask LG to confirm the exact model version and requirement before purchase.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
- LG US wall air conditioner category ↗Eleven LT equipment entries observed in initial category HTML; accessories excluded. Dynamic pagination is not proof of complete coverage. · Checked 2026-10-12
- LG owner manual — cool ↗Support associations checked 2026-10-12; visually reviewed 2026-10-13. Printed/PDF page 9 explicitly lists LT0816CER, LT1016CER, LT12124CNR (115 V) and LT1036CER, LT1236CER, LT1430CNR (230 V), 15 A circuit and outlet drawings; pages 11–13 packing list and LGE sleeve Procedure A. LT1216CER has a separate exact support manual. · Checked 2026-10-13
- LG LT1236CER — current product specifications ↗Specifications > Electrical Ratings, Performance, Features and Dimensions/Weight; public page specification data; product modelStatus ACTIVE checked separately from stock. · Checked 2026-10-13
- LG LT1236CER — exact support/document association ↗Selected support sales suffix and Download Manuals list; suffix is not automatically an alias of another physical generation. · Checked 2026-10-12
- LG LT1236CER — linked specification sheet ↗Exact SKU specifications, refrigerant and Optional Accessories. Dates differ across PDFs; older electrical/performance tables are not merged into current page values. · Checked 2026-10-12
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
Reviewed marketed SKU and UPC 048231379649; selected support LT1236CER.AT3AYO4. Base model is not an alias of every historical sales suffix.
Manufacturer specifications ↗More checks neededLG
- Nominal supply
- 230 V
- Nominal cooling rating
- 11,200 BTU/h
- Heating
- Electric heat
- Plug
- NEMA 6-20P
- Specified circuit / fuse
- 20 A
- CEER (nominal rating)
- 9.7
Reported indoor noise: 59 dBA (Manufacturer rating; fan speed and test conditions not stated). Test conditions vary by source.
Verify rated currentWhy these facts need checking
- Rated cooling current is disputed between sources. Ask LG to confirm the exact model version and requirement before purchase.
Checks before purchase (7)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Rated cooling current is disputed between sources. Ask LG to confirm the exact model version and requirement before purchase.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
- LG US wall air conditioner category ↗Eleven LT equipment entries observed in initial category HTML; accessories excluded. Dynamic pagination is not proof of complete coverage. · Checked 2026-10-12
- LG owner manual — oldheat ↗Support-selected LT1037HNR.AC3AUSB / LT1237HNR.ASWAUSH; original download filename explicitly R410A. Visually reviewed printed/PDF page 9: 20 A circuit and consistent perpendicular plug/outlet drawings. Not an R32 manual. · Checked 2026-10-13
- LG LT1237HNR — current product specifications ↗Specifications > Electrical Ratings, Performance, Features and Dimensions/Weight; public page specification data; product modelStatus ACTIVE checked separately from stock. · Checked 2026-10-13
- LG LT1237HNR — exact support/document association ↗Selected support sales suffix and Download Manuals list; suffix is not automatically an alias of another physical generation. · Checked 2026-10-12
- LG LT1237HNR — linked specification sheet ↗Exact SKU specifications, refrigerant and Optional Accessories. Dates differ across PDFs; older electrical/performance tables are not merged into current page values. · Checked 2026-10-12
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
Reviewed marketed SKU and UPC 048231382281; selected support LT1237HNR.ASWAUSH. Base model is not an alias of every historical sales suffix.
Manufacturer specifications ↗More checks neededLG
- Nominal supply
- 230 V
- Nominal cooling rating
- 14,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 6-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 9.3
Reported indoor noise: 58 dBA (Manufacturer rating; fan speed and test conditions not stated). Test conditions vary by source.
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
- LG US wall air conditioner category ↗Eleven LT equipment entries observed in initial category HTML; accessories excluded. Dynamic pagination is not proof of complete coverage. · Checked 2026-10-12
- LG owner manual — cool ↗Support associations checked 2026-10-12; visually reviewed 2026-10-13. Printed/PDF page 9 explicitly lists LT0816CER, LT1016CER, LT12124CNR (115 V) and LT1036CER, LT1236CER, LT1430CNR (230 V), 15 A circuit and outlet drawings; pages 11–13 packing list and LGE sleeve Procedure A. LT1216CER has a separate exact support manual. · Checked 2026-10-13
- LG LT1430CNR — current product specifications ↗Specifications > Electrical Ratings, Performance, Features and Dimensions/Weight; public page specification data; product modelStatus ACTIVE checked separately from stock. · Checked 2026-10-13
- LG LT1430CNR — exact support/document association ↗Selected support sales suffix and Download Manuals list; suffix is not automatically an alias of another physical generation. · Checked 2026-10-12
- NEMA receptacle configurations — manufacturer reference ↗Printed/PDF page 12: labelled 5-15R, 6-15R and 6-20R face drawings. Used only to identify the matching receptacle drawn in an exact AC manual, never to infer the required breaker. · Checked 2026-10-13
Reviewed marketed SKU and UPC 048231604666; selected support LT1430CNR.AT3AUSB. Base model is not an alias of every historical sales suffix.
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 115 V
- Nominal cooling rating
- 8,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.1
Wi-Fi documented
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT08B10A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 115 V
- Nominal cooling rating
- 10,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.1
Wi-Fi documented
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT10B10A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 230 V
- Nominal cooling rating
- 10,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 6-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10.1
Wi-Fi documented
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT10B30A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 115 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10
Wi-Fi documented
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT12B10A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 6-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 10
Wi-Fi documented
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT12B30A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 230 V
- Nominal cooling rating
- 14,000 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 6-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 9.3
Wi-Fi documented
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UCT14B30A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 115 V
- Nominal cooling rating
- 8,000 BTU/h
- Heating
- Electric heat
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 9.6
Wi-Fi documented
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UET08B11A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 230 V
- Nominal cooling rating
- 10,000 BTU/h
- Heating
- Electric heat
- Plug
- NEMA 6-20P
- Specified circuit / fuse
- 20 A
- CEER (nominal rating)
- 9.6
Wi-Fi documented
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UET10B33A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 230 V
- Nominal cooling rating
- 12,000 BTU/h
- Heating
- Electric heat
- Plug
- NEMA 6-20P
- Specified circuit / fuse
- 20 A
- CEER (nominal rating)
- 9.6
Wi-Fi documented
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UET12B33A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 230 V
- Nominal cooling rating
- 14,000 BTU/h
- Heating
- Electric heat
- Plug
- NEMA 6-20P
- Specified circuit / fuse
- 20 A
- CEER (nominal rating)
- 9.3
Wi-Fi documented
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Check the exact model at a store
UET14B33A at AJ Madison ↗Model identity checked 2026-10-13
Ordinary store links; no affiliate commission. Confirm the model, nameplate, sleeve, parts, price and availability with the seller before ordering.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
UCT/UET B-series, final A suffix, R-32; specifications scoped to the 2026 brochure revision 02-19-25
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 115 V
- Nominal cooling rating
- 13,500 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 5-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 13.2
Inverter documentedWi-Fi documented
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
2026 WallMaster inverter / R-32, final B suffix (BR_WM_REV 07-15-25)
Manufacturer specifications ↗More checks neededFriedrich
- Nominal supply
- 230 V
- Nominal cooling rating
- 16,800 BTU/h
- Heating
- Cooling only
- Plug
- NEMA 6-15P
- Specified circuit / fuse
- 15 A
- CEER (nominal rating)
- 12.6
Inverter documentedWi-Fi documented
Checks before purchase (6)
- Identify the actual sleeve before a physical fit decision.
- Confirm the actual supply voltage.
- Compare the actual circuit with the exact manufacturer circuit/fuse requirement.
- Exact plug/receptacle configuration needs confirmation.
- Room estimate or model capacity at the selected voltage needs checking.
- Enter 100–2,500 sq ft for the ENERGY STAR chart. Other room sizes need an individual sizing assessment.
Sleeves, required parts and sources
No sleeve relationship has been established under your installation answers.
Evidence for this model and installation
2026 WallMaster inverter / R-32, final B suffix (BR_WM_REV 07-15-25)
Manufacturer specifications ↗